SX TT LUT

17:20
  • Waiting for telescope, starting OVMS.
  • Had to transfer Doug's scripts back to the soul machine, from the flao machine. Somebody erased them, not pointing any fingers, Alfio! wink
  • I made a directory called: /home/AOeng/SOUL/auxloopsDougScriptsDoNotDelete/scripts
18:38
  • 1000 Hz Mag 11.9, bin 1, gain 600, heading to 75 degrees elevation.
18:56
  • At 75. Adjusted lamp to mag 12.5
  • Going to 500 Hz, there is only 2.5 photon's per subap. I don't want to lose the pupils when I am rotating, or moving the telescope.
  • Moving to angle 450
    0.4 0.0 0.0
    ssh LBTO@obs3 "echo \"/lbt/irtc/current/bin/irc RotServicePosition 450.000000 left\" | tcsh"
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.8 0.15 0.105626
    Saved tracknum: 20190315_190323
    Saved tracknum: 20190315_190404
    Saved tracknum: 20190315_190444

  • Moving to angle 420
    0.4 0.0 0.0
    ssh LBTO@obs3 "echo \"/lbt/irtc/current/bin/irc RotServicePosition 420.000000 left\" | tcsh"
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.8 0.15 0.105626
    Saved tracknum: 20190315_190615
    Saved tracknum: 20190315_190655
    Saved tracknum: 20190315_190732

  • Moving to angle 390
    0.4 0.0 0.0
    ssh LBTO@obs3 "echo \"/lbt/irtc/current/bin/irc RotServicePosition 390.000000 left\" | tcsh"
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.8 0.15 0.105626
    Saved tracknum: 20190315_190904
    Saved tracknum: 20190315_190942
    Saved tracknum: 20190315_191019

  • Moving to angle 360
    0.4 0.0 0.0
    ssh LBTO@obs3 "echo \"/lbt/irtc/current/bin/irc RotServicePosition 360.000000 left\" | tcsh"
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.8 0.15 0.105626
    Saved tracknum: 20190315_191151
    Saved tracknum: 20190315_191230
    Saved tracknum: 20190315_191310

  • Moving to angle 330
    0.4 0.0 0.0
    ssh LBTO@obs3 "echo \"/lbt/irtc/current/bin/irc RotServicePosition 330.000000 left\" | tcsh"
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.8 0.15 0.105626
    Saved tracknum: 20190315_191442
    Saved tracknum: 20190315_191520
    Saved tracknum: 20190315_191600

  • Moving to angle 300
    0.4 0.0 0.0
    ssh LBTO@obs3 "echo \"/lbt/irtc/current/bin/irc RotServicePosition 300.000000 left\" | tcsh"
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.8 0.15 0.105626
    Saved tracknum: 20190315_191735
    Saved tracknum: 20190315_191813
    Saved tracknum: 20190315_191852

  • Saved tracknum: 20190315_191852
    Moving to angle 270
    0.4 0.0 0.0
    ssh LBTO@obs3 "echo \"/lbt/irtc/current/bin/irc RotServicePosition 270.000000 left\" | tcsh"
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.8 0.15 0.105626
    Saved tracknum: 20190315_192023
    Saved tracknum: 20190315_192103
    Saved tracknum: 20190315_192143

  • Moving to angle 240
    0.4 0.0 0.0
    ssh LBTO@obs3 "echo \"/lbt/irtc/current/bin/irc RotServicePosition 240.000000 left\" | tcsh"
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.8 0.15 0.105626
    Saved tracknum: 20190315_192314
    Saved tracknum: 20190315_192353
    Saved tracknum: 20190315_192433

  • Moving to angle 210
    0.4 0.0 0.0
    ssh LBTO@obs3 "echo \"/lbt/irtc/current/bin/irc RotServicePosition 210.000000 left\" | tcsh"
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.8 0.15 0.105626
    Saved tracknum: 20190315_192606
    Saved tracknum: 20190315_192646
    Saved tracknum: 20190315_192726

  • Moving to angle 180
    0.4 0.0 0.0
    ssh LBTO@obs3 "echo \"/lbt/irtc/current/bin/irc RotServicePosition 180.000000 left\" | tcsh"
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.8 0.15 0.105626
    Saved tracknum: 20190315_192857
    Saved tracknum: 20190315_192936
    Saved tracknum: 20190315_193013

  • Moving to angle 150
    0.4 0.0 0.0
    ssh LBTO@obs3 "echo \"/lbt/irtc/current/bin/irc RotServicePosition 150.000000 left\" | tcsh"
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.8 0.15 0.105626
    Saved tracknum: 20190315_193146
    Saved tracknum: 20190315_193226
    Saved tracknum: 20190315_193304

  • Moving to angle 120
    0.4 0.0 0.0
    ssh LBTO@obs3 "echo \"/lbt/irtc/current/bin/irc RotServicePosition 120.000000 left\" | tcsh"
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.8 0.15 0.105626
    Saved tracknum: 20190315_193437
    Saved tracknum: 20190315_193516
    Saved tracknum: 20190315_193554

  • Moving to angle 90
    0.4 0.0 0.0
    ssh LBTO@obs3 "echo \"/lbt/irtc/current/bin/irc RotServicePosition 90.000000 left\" | tcsh"
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.8 0.15 0.105626
    Saved tracknum: 20190315_193727
    Saved tracknum: 20190315_193807
    Saved tracknum: 20190315_193846

  • Moving to angle 60
    0.4 0.0 0.0
    ssh LBTO@obs3 "echo \"/lbt/irtc/current/bin/irc RotServicePosition 60.000000 left\" | tcsh"
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.8 0.15 0.105626
    Saved tracknum: 20190315_194019
    Saved tracknum: 20190315_194100
    Saved tracknum: 20190315_194139

  • Moving to angle 30
    0.4 0.0 0.0
    ssh LBTO@obs3 "echo \"/lbt/irtc/current/bin/irc RotServicePosition 30.000000 left\" | tcsh"
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.8 0.15 0.105626
    Saved tracknum: 20190315_194309
    Saved tracknum: 20190315_194349
    Saved tracknum: 20190315_194429

  • Moving to angle 0
    0.7254 0.0 0.0
    ssh LBTO@obs3 "echo \"/lbt/irtc/current/bin/irc RotServicePosition 0.000000 left\" | tcsh"
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    1.4508 0.3492 0.11917
    Saved tracknum: 20190315_195106
    Saved tracknum: 20190315_195147
    Saved tracknum: 20190315_195226

  • Moving to angle -30
    0.73755 0.0 0.0
    ssh LBTO@obs3 "echo \"/lbt/irtc/current/bin/irc RotServicePosition -30.000000 left\" | tcsh"
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    1.4751 0.3492 0.159905
    Saved tracknum: 20190315_195902
    Saved tracknum: 20190315_195943
    Saved tracknum: 20190315_200022

  • Moving to angle -60
    0.73755 0.0 0.0
    ssh LBTO@obs3 "echo \"/lbt/irtc/current/bin/irc RotServicePosition -60.000000 left\" | tcsh"
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    1.4751 0.3492 0.159905
    Saved tracknum: 20190315_200156
    Saved tracknum: 20190315_200236
    Saved tracknum: 20190315_200315
    Moving to angle -90
    0.715 0.0 0.0
    ssh LBTO@obs3 "echo \"/lbt/irtc/current/bin/irc RotServicePosition -90.000000 left\" | tcsh"
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    1.43 0.35 0.181384
    Saved tracknum: 20190315_200454
    Saved tracknum: 20190315_200532
    Saved tracknum: 20190315_200610

20:08
  • Flat: 20190315_flat_75Degrees
  • Heading to 60
20:12
  • At 60
  • Moving to angle -90
    0.42165 0.0 0.0
    ssh LBTO@obs3 "echo \"/lbt/irtc/current/bin/irc RotServicePosition -90.000000 left\" | tcsh"
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.8433 0.1872 0.128095
    Saved tracknum: 20190315_201431
    Saved tracknum: 20190315_201512
    Saved tracknum: 20190315_201554

  • Moving to angle -60
    0.42165 0.0 0.0
    ssh LBTO@obs3 "echo \"/lbt/irtc/current/bin/irc RotServicePosition -60.000000 left\" | tcsh"
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.8433 0.1872 0.128095
    Saved tracknum: 20190315_201726
    Saved tracknum: 20190315_201808
    Saved tracknum: 20190315_201849

  • Moving to angle -30
    0.42165 0.0 0.0
    ssh LBTO@obs3 "echo \"/lbt/irtc/current/bin/irc RotServicePosition -30.000000 left\" | tcsh"
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.8433 0.1872 0.128095
    Saved tracknum: 20190315_202023
    Saved tracknum: 20190315_202101
    Saved tracknum: 20190315_202141

  • Know what? I'm going back to 1000Hz, the vibrations are too bad.
  • Moving to angle 0
    0.1908 0.0 0.0
    ssh LBTO@obs3 "echo \"/lbt/irtc/current/bin/irc RotServicePosition 0.000000 left\" | tcsh"
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.3816 0.2718 0.190331
    Saved tracknum: 20190315_203316
    Saved tracknum: 20190315_203355
    Saved tracknum: 20190315_203434

  • Moving to angle 30
    0.1908 0.0 0.0
    ssh LBTO@obs3 "echo \"/lbt/irtc/current/bin/irc RotServicePosition 30.000000 left\" | tcsh"
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.3816 0.2718 0.190331
    Saved tracknum: 20190315_203608
    Saved tracknum: 20190315_203647
    Saved tracknum:

  • Moving to angle 60
    0.1908 0.0 0.0
    ssh LBTO@obs3 "echo \"/lbt/irtc/current/bin/irc RotServicePosition 60.000000 left\" | tcsh"
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.3816 0.2718 0.190331
    Saved tracknum: 20190315_203902
    Saved tracknum: 20190315_203943
    Saved tracknum: 20190315_204022

  • Moving to angle 90
    0.1908 0.0 0.0
    ssh LBTO@obs3 "echo \"/lbt/irtc/current/bin/irc RotServicePosition 90.000000 left\" | tcsh"
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.3816 0.2718 0.190331
    Saved tracknum: 20190315_204153
    Saved tracknum: 20190315_204234
    Saved tracknum: 20190315_204313

  • Moving to angle 120
    0.217049 0.0 0.0
    ssh LBTO@obs3 "echo \"/lbt/irtc/current/bin/irc RotServicePosition 120.000000 left\" | tcsh"
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.434098 0.26891 0.192078
    Saved tracknum: 20190315_204449
    Saved tracknum: 20190315_204527
    Saved tracknum: 20190315_204606

  • Moving to angle 150
    0.217049 0.0 0.0
    ssh LBTO@obs3 "echo \"/lbt/irtc/current/bin/irc RotServicePosition 150.000000 left\" | tcsh"
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.434098 0.26891 0.192078
    Saved tracknum: 20190315_204739
    Saved tracknum:
    Saved tracknum: 20190315_204858

  • Moving to angle 180
    0.217049 0.0 0.0
    ssh LBTO@obs3 "echo \"/lbt/irtc/current/bin/irc RotServicePosition 180.000000 left\" | tcsh"
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.434098 0.26891 0.192078
    Saved tracknum: 20190315_205030
    Saved tracknum: 20190315_205112
    Saved tracknum: 20190315_205153

  • Moving to angle 210
    0.217049 0.0 0.0
    ssh LBTO@obs3 "echo \"/lbt/irtc/current/bin/irc RotServicePosition 210.000000 left\" | tcsh"
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.434098 0.26891 0.192078
    Saved tracknum:
    Saved tracknum: 20190315_205406
    Saved tracknum:

  • Moving to angle 240
    0.217049 0.0 0.0
    ssh LBTO@obs3 "echo \"/lbt/irtc/current/bin/irc RotServicePosition 240.000000 left\" | tcsh"
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.434098 0.26891 0.192078
    Saved tracknum: 20190315_205621
    Saved tracknum: 20190315_205701
    Saved tracknum: 20190315_205744

  • Moving to angle 270
    0.217049 0.0 0.0
    ssh LBTO@obs3 "echo \"/lbt/irtc/current/bin/irc RotServicePosition 270.000000 left\" | tcsh"
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.434098 0.26891 0.192078
    Saved tracknum: 20190315_205916
    Saved tracknum: 20190315_205956
    Saved tracknum:

  • Moving to angle 300
    0.217049 0.0 0.0
    ssh LBTO@obs3 "echo \"/lbt/irtc/current/bin/irc RotServicePosition 300.000000 left\" | tcsh"
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.434098 0.26891 0.192078
    Saved tracknum: 20190315_210210
    Saved tracknum: 20190315_210252
    Saved tracknum: 20190315_210331

  • Moving to angle 330
    0.217049 0.0 0.0
    ssh LBTO@obs3 "echo \"/lbt/irtc/current/bin/irc RotServicePosition 330.000000 left\" | tcsh"
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.434098 0.26891 0.192078
    Saved tracknum:
    Saved tracknum:
    Saved tracknum: 20190315_210626

  • Moving to angle 360
    0.217049 0.0 0.0
    ssh LBTO@obs3 "echo \"/lbt/irtc/current/bin/irc RotServicePosition 360.000000 left\" | tcsh"
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.434098 0.26891 0.192078
    Saved tracknum: 20190315_210801
    Saved tracknum: 20190315_210842
    Saved tracknum: 20190315_210922

  • Moving to angle 390
    0.217049 0.0 0.0
    ssh LBTO@obs3 "echo \"/lbt/irtc/current/bin/irc RotServicePosition 390.000000 left\" | tcsh"
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.434098 0.26891 0.192078
    Saved tracknum: 20190315_211055
    Saved tracknum:
    Saved tracknum:

  • Moving to angle 420
    0.217049 0.0 0.0
    ssh LBTO@obs3 "echo \"/lbt/irtc/current/bin/irc RotServicePosition 420.000000 left\" | tcsh"
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.434098 0.26891 0.192078
    Saved tracknum: 20190315_211348
    Saved tracknum: 20190315_211430
    Saved tracknum: 20190315_211509

  • Moving to angle 450
    0.217049 0.0 0.0
    ssh LBTO@obs3 "echo \"/lbt/irtc/current/bin/irc RotServicePosition 450.000000 left\" | tcsh"
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.434098 0.26891 0.192078
    Saved tracknum: 20190315_211649
    Saved tracknum: 20190315_211730
    Saved tracknum: 20190315_211809

21:19
  • Heading to 45
  • Flat: 20190315_flat_60Degrees
21:27
  • At 45
  • Moving to angle 450
    0.1908 0.0 0.0
    ssh LBTO@obs3 "echo \"/lbt/irtc/current/bin/irc RotServicePosition 450.000000 left\" | tcsh"
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.3816 0.18 0.18
    Saved tracknum: 20190315_213001
    Saved tracknum: 20190315_213042
    Saved tracknum: 20190315_213124

  • Moving to angle 420
    0.1908 0.0 0.0
    ssh LBTO@obs3 "echo \"/lbt/irtc/current/bin/irc RotServicePosition 420.000000 left\" | tcsh"
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.3816 0.18 0.18
    Saved tracknum: 20190315_213257
    Saved tracknum: 20190315_213338
    Saved tracknum: 20190315_213420

  • Moving to angle 390
    0.1908 0.0 0.0
    ssh LBTO@obs3 "echo \"/lbt/irtc/current/bin/irc RotServicePosition 390.000000 left\" | tcsh"
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.3816 0.18 0.18
    Saved tracknum: 20190315_213555
    Saved tracknum: 20190315_213636
    Saved tracknum: 20190315_213715

  • Moving to angle 360
    0.1908 0.0 0.0
    ssh LBTO@obs3 "echo \"/lbt/irtc/current/bin/irc RotServicePosition 360.000000 left\" | tcsh"
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.3816 0.18 0.18
    Saved tracknum: 20190315_213850
    Saved tracknum: 20190315_213932
    Saved tracknum: 20190315_214010

  • Moving to angle 330
    0.1908 0.0 0.0
    ssh LBTO@obs3 "echo \"/lbt/irtc/current/bin/irc RotServicePosition 330.000000 left\" | tcsh"
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.3816 0.18 0.18
    Saved tracknum: 20190315_214144
    Saved tracknum:
    Saved tracknum: 20190315_214307

  • Moving to angle 300
    0.1908 0.0 0.0
    ssh LBTO@obs3 "echo \"/lbt/irtc/current/bin/irc RotServicePosition 300.000000 left\" | tcsh"
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.3816 0.18 0.18
    Saved tracknum: 20190315_214442
    Saved tracknum: 20190315_214521
    Saved tracknum: 20190315_214601

  • Moving to angle 270
    0.1908 0.0 0.0
    ssh LBTO@obs3 "echo \"/lbt/irtc/current/bin/irc RotServicePosition 270.000000 left\" | tcsh"
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.3816 0.18 0.18
    Saved tracknum: 20190315_214736
    Saved tracknum: 20190315_214817
    Saved tracknum: 20190315_214856

  • Moving to angle 240
    0.1908 0.0 0.0
    ssh LBTO@obs3 "echo \"/lbt/irtc/current/bin/irc RotServicePosition 240.000000 left\" | tcsh"
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.3816 0.18 0.18
    Saved tracknum: 20190315_215031
    Saved tracknum:
    Saved tracknum: 20190315_215153

  • Moving to angle 210
    0.1908 0.0 0.0
    ssh LBTO@obs3 "echo \"/lbt/irtc/current/bin/irc RotServicePosition 210.000000 left\" | tcsh"
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.3816 0.18 0.18
    Saved tracknum: 20190315_215328
    Saved tracknum: 20190315_215409
    Saved tracknum:

  • Moving to angle 180
    0.1908 0.0 0.0
    ssh LBTO@obs3 "echo \"/lbt/irtc/current/bin/irc RotServicePosition 180.000000 left\" | tcsh"
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.3816 0.18 0.18
    Saved tracknum: 20190315_215624
    Saved tracknum: 20190315_215704
    Saved tracknum: 20190315_215747

  • Moving to angle 150
    0.1908 0.0 0.0
    ssh LBTO@obs3 "echo \"/lbt/irtc/current/bin/irc RotServicePosition 150.000000 left\" | tcsh"
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.3816 0.18 0.18
    Saved tracknum: 20190315_215919
    Saved tracknum: 20190315_215959
    Saved tracknum:

  • Moving to angle 120
    0.1908 0.0 0.0
    ssh LBTO@obs3 "echo \"/lbt/irtc/current/bin/irc RotServicePosition 120.000000 left\" | tcsh"
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.3816 0.18 0.18
    Saved tracknum: 20190315_220216
    Saved tracknum: 20190315_220257
    Saved tracknum: 20190315_220339

  • Moving to angle 90
    0.1908 0.0 0.0
    ssh LBTO@obs3 "echo \"/lbt/irtc/current/bin/irc RotServicePosition 90.000000 left\" | tcsh"
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.3816 0.18 0.18
    Saved tracknum: 20190315_220514
    Saved tracknum: 20190315_220555
    Saved tracknum: 20190315_220635

  • Moving to angle 60
    0.1908 0.0 0.0
    ssh LBTO@obs3 "echo \"/lbt/irtc/current/bin/irc RotServicePosition 60.000000 left\" | tcsh"
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.3816 0.18 0.18
    Saved tracknum: 20190315_220808
    Saved tracknum: 20190315_220849
    Saved tracknum: 20190315_220931

  • Moving to angle 30
    0.1908 0.0 0.0
    ssh LBTO@obs3 "echo \"/lbt/irtc/current/bin/irc RotServicePosition 30.000000 left\" | tcsh"
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.3816 0.18 0.18
    Saved tracknum: 20190315_221108
    Saved tracknum:
    Saved tracknum:

  • Moving to angle 0
    0.215 0.0 0.0
    ssh LBTO@obs3 "echo \"/lbt/irtc/current/bin/irc RotServicePosition 0.000000 left\" | tcsh"
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.43 0.18 0.18
    Saved tracknum: 20190315_221402
    Saved tracknum: 20190315_221445
    Saved tracknum: 20190315_221525

  • Moving to angle -30
    0.215 0.0 0.0
    ssh LBTO@obs3 "echo \"/lbt/irtc/current/bin/irc RotServicePosition -30.000000 left\" | tcsh"
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.43 0.18 0.18
    Saved tracknum: 20190315_221658
    Saved tracknum: 20190315_221740
    Saved tracknum: 20190315_221821

  • Moving to angle -60
    0.215 0.0 0.0
    ssh LBTO@obs3 "echo \"/lbt/irtc/current/bin/irc RotServicePosition -60.000000 left\" | tcsh"
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.43 0.18 0.18
    Saved tracknum: 20190315_221956
    Saved tracknum: 20190315_222038
    Saved tracknum: 20190315_222118

  • Moving to angle -90
    0.215 0.0 0.0
    ssh LBTO@obs3 "echo \"/lbt/irtc/current/bin/irc RotServicePosition -90.000000 left\" | tcsh"
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.43 0.18 0.18
    Saved tracknum: 20190315_222256
    Saved tracknum: 20190315_222338
    Saved tracknum: 20190315_222420

  • Flat: 20190315_flat_45Degrees

-- GregoryTaylor - 15 Mar 2019
Topic revision: r2 - 15 Mar 2019, GregoryTaylor
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback