2019029 DX 4D alignment and Flat Measurement.

17:30 Get the telescope
  • Had Elliott pull on RR Barrel. OK now

19:30 Performed a couple hexaligns. Left with some Astigmatim
  • Initial flat with 444 modes, KL_v26 Actuators:
    Initial_4D.jpg
  • Initial 4D Image with 444 modes, KL_v26 Actuators:
    Initial_surf_132nm.jpg
  • Initial Mirror with 444 modes, KL_v26 Actuators:
    initial_mirror_444_modes.jpg

19:38 Measure new reconstructor
  • Trigger problem in tree house. Mike fix it

20:53 Measure recon 0-40
  • AdOpt> print, i4d_opt_intmat(0,40,AMPRMS=250e-9)
    • 20190129_205342
  • >>> comm4d.produce('20190129_205342')
  • IDL> print, if_redux(/MODAL, '20190129_205342')
  • IDL> print, build_int_mat('20190129_205342')
  • AdOpt> print, opt_int_mat_reduce2(40, track='20190129_205342')

21:08 41-100
  • AdOpt>print, i4d_opt_intmat(41,100)
    • 20190129_210853
  • >>> comm4d.produce('20190129_210853')
  • IDL> print, if_redux(/MODAL, '20190129_210853')
  • IDL> print, build_int_mat(['20190129_205342','20190129_210853'])
  • AdOpt> print, opt_int_mat_reduce2(100, track='20190129_205342')
  • removed 100 because in the next set

21:25 100-201
  • AdOpt>print, i4d_opt_intmat(101,201)
    • 20190129_212516
  • >>> comm4d.produce('20190129_212516')
  • IDL> print, if_redux(/MODAL, '20190129_212516')
  • IDL> print, build_int_mat(['20190129_205342','20190129_210853','20190129_212516'])
  • AdOpt> print, opt_int_mat_reduce2(200, track='20190129_205342'))

21:25 202-300
  • AdOpt>print, i4d_opt_intmat(202,300)
    • 20190129_215051
  • IDL> print, if_redux(/MODAL, '20190129_21255051') Failed, no trigger image found

22:12 202-300
  • AdOpt>print, i4d_opt_intmat(202,300)
    • 20190129_221259
  • >>> comm4d.produce('20190129_221259')
  • IDL> print, if_redux(/MODAL, '20190129_221259')
  • IDL> print, build_int_mat(['20190129_205342','20190129_210853','20190129_212516','20190129_221259'])
  • AdOpt> print, opt_int_mat_reduce2(300, track='20190129_205342'))
  • /local/aomeas/adsec_calib/flat/20190129_223400/flattening_result.sav BEST! 641 modes

22:39 301-400
  • AdOpt>print, i4d_opt_intmat(301,400)
    • 20190129_223922
  • >>> comm4d.produce('20190129_223922')
  • IDL> print, if_redux(/MODAL, '20190129_223922')
  • IDL> print, build_int_mat(['20190129_205342','20190129_210853','20190129_212516','20190129_221259','20190129_223922'])
  • AdOpt> print, opt_int_mat_reduce2(400, track='20190129_205342'))

  • 300 modes /local/aomeas/adsec_calib/flat/20190129_230829/flattening_result.sav

KL_v22

  • 300 modes /local/aomeas/adsec_calib/flat/20190129_233149/flattening_result.sav
  • 350 modes /local/aomeas/adsec_calib/flat/20190129_233359/flattening_result.sav
  • 400 modes /local/aomeas/adsec_calib/flat/20190129_233638/flattening_result.sav
  • 400 modes /local/aomeas/adsec_calib/flat/20190129_233825/flattening_result.sav
  • 400 modes /local/aomeas/adsec_calib/flat/20190129_234008/flattening_result.sav
  • 400 modes /local/aomeas/adsec_calib/flat/20190129_234259/flattening_result.sav

-- DougMiller - 29 Jan 2019
I Attachment Action Size Date Who Comment
Initial_4D.jpgjpg Initial_4D.jpg manage 98 K 29 Jan 2019 - 21:17 DougMiller Initial flat with 444 modes, KL_v26 Actuators
Initial_surf_132nm.jpgjpg Initial_surf_132nm.jpg manage 96 K 29 Jan 2019 - 21:18 DougMiller Initial Surface with 444 modes, KL_v26 Actuators
initial_mirror_444_modes.jpgjpg initial_mirror_444_modes.jpg manage 211 K 29 Jan 2019 - 21:23 DougMiller Initial Mirror with 444 modes, KL_v26 Actuators
Topic revision: r3 - 30 Jan 2019, DougMiller
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback