DX ON Sky

00:54
  • Waiting to open
01:38
  • pointing
01:56
  • Camera Lens Stuck
02:03
  • re-sending the preset
02:20
  • Getting Odd errors on the adsec, like the hexapod won't move, or something, it drives too much TT and the adsec safe-skips
  • I've restarted the adsec and the MOXA is already running. I looked on the web GUI of the MOXA and there didn't seem to be anything wrong, but I restarted it anyway
  • DIDN'T HAVE THE CORRECT ACTUATOR MAP LOADED!!!!!!
  • Went to seeing limited
04:51
  • Doing ESM for the next while
  • Presetting now
  • Everything looks OK
  • Gains 2.35 1.5 1.5, manually set (TT is arbitrary)
  • Dataset: 20190212_050836, 050855, 050925, 050953
  • Jochen tells me that the image quality is 0.3" seeing is 0.77.
08:11
  • An offset failed, stages not moving?
  • WfsArbitrator_71112|ERR| 1555|2019-02-12 08:06:31.624464| MAIN > RETRY: Stages position not reached (-5001) TIMEOUT_ERROR
  • The stages were stuck, but I was able to un-stick them, finally. See IT#7567.
  • Moved on to seeing limited for a while
10:51
  • Doing new preset
  • Pupil rotator didn't home properly, Don't know how that happened.
  • Homed it and now everything is OK, didn't have to re-send the preset, just repeat 'Close Loop'.
  • Of course, 'Close Loop' takes way to long to execute, I must have a word with Enrico et al.
  • MasterDiagnostic_19410|ERR| 83167|2019-02-12 11:56:48.898113|ADAPTIVE-SECONDARY > Detected a wrong filotto (BcuSwitch frame header don't match BcuMirror_0 header) !!!
    MasterDiagnostic_19410|WAR| 83168|2019-02-12 11:56:48.898130|ADAPTIVE-SECONDARY > Wrong filotto. Frame skipped.
    MasterDiagnostic_19410|ERR| 83169|2019-02-12 11:56:48.899252|ADAPTIVE-SECONDARY > > FRAME BCU_SWITCH HEADER:
    MasterDiagnostic_19410|ERR| 83170|2019-02-12 11:56:48.899273|ADAPTIVE-SECONDARY > > FRAME BCU_MIRROR_0 HEADER:

  • We were at 89 degrees elevation, I think that things couldn't keep up.
12:01
  • Stopping AO for tonight.