20190206 DX 4D alignment and Flat Measurement.

KL_v26

09:00 Look at Pyramid Pupil and then 4D
  • Initial Pupil with default.sav, 637 modes:
    Initial_pupil_default.sav_637m.jpg
  • Initial 4D with default.sav, 637 modes:
    initial_4d_default.sav_637m.jpg Initial_Surf_default.sav_637m.jpg
  • initial Mirror with default.sav, 637 modes:
    Initial_Mirror_default.sav_637m.jpg

  • print, hexalign(/apply)
  • Initial 4D hexalign with default.sav, 637 modes:
    initial_4d_hex_default.sav_637m.jpg

  • AdOpt>print, opt_int_mat_reduce2(400, track='20190205_063210')
    • /local/aomeas/adsec_calib/flat/20190206_092336/flattening_result.sav
  • Flat 1 4D with 400 modes:
    flat_1_4d.jpg flat_1_surf.jpg
  • flat 1 Mirror with 400 modes:
    flat_1_mirror.jpg
  • AdOpt>print, opt_int_mat_reduce2(400, track='20190205_063210')
    • /local/aomeas/adsec_calib/flat/20190206_093059/flattening_result.sav

New Flat

09:32
  • AdOpt> print, i4d_opt_intmat(401,600)
    • 20190206_093327
  • AdOpt>print, i4d_opt_intmat(201,400)
    • 20190206_093634
  • AdOpt>print, i4d_opt_intmat(0,200)
    • 20190206_093805
  • Is 374 bad? Not moving much...
  • >>> comm4d.produce('20190206_093327')
  • >>> comm4d.produce('20190206_093634')
  • IDL> print, build_int_mat(['20190205_063210','20190206_093634','20190206_093327'])

10:27
  • AdOpt>print, opt_int_mat_reduce2(400, track='20190205_063210')
    • /local/aomeas/adsec_calib/flat/20190206_102708/flattening_result.sav
  • AdOpt>print, opt_int_mat_reduce2(500, track='20190205_063210')
    • Not any better than 400 m
  • AdOpt>print, opt_int_mat_reduce2(600, track='20190205_063210')
    • Look worse

10:35 Apply 20190206_102708/flattening_result.sav
  • 375 modes
  • Act 374 has high forces (0.53N)
  • Remove 374 from position
  • Stop/Start
  • Flat 20190206_102708/flattening_result.sav
    • 636 modes
    • 3 images
  • AdOpt>print, opt_int_mat_reduce2(400, track='20190205_063210')
    • /local/aomeas/adsec_calib/flat/20190206_104652/flattening_result.sav
    • not as good as 20190206_102708/flattening_result.sav

11:09 Tip to 60 Elevation
  • alot of astigmatism and some quadrafoil(?)
  • AdOpt>print, opt_int_mat_reduce2(40, track='20190205_063210')
    • 3 images
  • AdOpt>print, opt_int_mat_reduce2(400, track='20190205_063210')
    • 4 images
  • IDL> print, hexalign(/apply)
    • Is Act 380 bad?

11:38 0-200 at 60 El
  • AdOpt>print, i4d_opt_intmat(0,200)
    • 20190206_113720
  • flat 20190206_102708/flattening_result.sav
  • AdOpt>print, opt_int_mat_reduce2(20, track='20190205_063210')
  • AdOpt>print, i4d_opt_intmat(0,200)
    • 20190206_114456
  • >>> comm4d.produce('20190206_114456')
  • IDL> print, build_int_mat(['20190206_114456'])
  • AdOpt>print, opt_int_mat_reduce2(20, track='20190206_114456')

12:34 0-200 at 60 El
  • AdOpt>print, i4d_opt_intmat(0,200)
    • 20190206_123343
  • AdOpt>print, opt_int_mat_reduce2(80, track='20190206_114456')
    • /local/aomeas/adsec_calib/flat/20190206_130525/flattening_result.sav
  • AdOpt>print, opt_int_mat_reduce2(100, track='20190206_114456')
    • /local/aomeas/adsec_calib/flat/20190206_130648/flattening_result.sav
  • AdOpt>print, opt_int_mat_reduce2(150, track='20190206_114456')
    • /local/aomeas/adsec_calib/flat/20190206_130809/flattening_result.sav
  • AdOpt>print, opt_int_mat_reduce2(200, track='20190206_114456')
    • /local/aomeas/adsec_calib/flat/20190206_130934/flattening_result.sav
    • apply: get 564
    • 3 images
    • apply: get 636

13:14 0-600 at 60 Elevation
  • print, i4d_opt_intmat(0,200)
    • 20190206_131403
  • print, i4d_opt_intmat(201,400)
    • 20190206_131710
  • print, i4d_opt_intmat(401,600)
    • 20190206_131808

Analysis completed on 20190207

  • AdOpt>print, if_redux(/MODAL, '20190206_131403')
  • AdOpt>print, if_redux(/MODAL, '20190206_131710')
  • print, build_int_mat(['20190206_131403','20190206_131710'])

-- DougMiller - 06 Feb 2019
I Attachment Action Size Date Who Comment
Initial_Mirror_default.sav_637m.jpgjpg Initial_Mirror_default.sav_637m.jpg manage 197 K 06 Feb 2019 - 10:03 DougMiller initial Mirror with default.sav, 637 modes
Initial_Surf_default.sav_637m.jpgjpg Initial_Surf_default.sav_637m.jpg manage 131 K 06 Feb 2019 - 10:02 DougMiller Initial Surface with default.sav, 637 modes
Initial_pupil_default.sav_637m.jpgjpg Initial_pupil_default.sav_637m.jpg manage 36 K 06 Feb 2019 - 10:03 DougMiller Initial Pupil with default.sav, 637 modes
flat_1_4d.jpgjpg flat_1_4d.jpg manage 93 K 06 Feb 2019 - 10:05 DougMiller Flat 1 4D with 400 modes
flat_1_mirror.jpgjpg flat_1_mirror.jpg manage 206 K 06 Feb 2019 - 10:06 DougMiller flat 1 Mirror with 400 modes
flat_1_surf.jpgjpg flat_1_surf.jpg manage 154 K 06 Feb 2019 - 10:06 DougMiller Flat 1 Surface with 400 modes
initial_4d_default.sav_637m.jpgjpg initial_4d_default.sav_637m.jpg manage 99 K 06 Feb 2019 - 10:02 DougMiller Initial 4D with default.sav, 637 modes
initial_4d_hex_default.sav_637m.jpgjpg initial_4d_hex_default.sav_637m.jpg manage 95 K 06 Feb 2019 - 10:04 DougMiller Initial 4D Hexalign with default.sav, 637 modes
Topic revision: r3 - 07 Feb 2019, DougMiller
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback