DX Reconstructors

17:06
  • Getting Started/Finding Source
17:24
  • Found Light
  • Hexapod -0.68 1.2 1.5 -340 -205 0
  • Baysides -74 -48 52.1
  • Cube -2.2 22.312
17:26
  • Starting with the same flat from yesterday, going to run a 400 mode recon with the 66mode in closed loop, to see if that lets me see light on the right edge.
  • Same disturbance from yesterday.
  • Intmat: 20190104_173056
  • Recon: 20190104_173919
  • Nope, the one from yesterday gets the light better in the left hand side.
  • It's fairly close, so I'm going to take a really long dataset, to see if we can get any signal in that hole.
17:48
  • New Flat: 20190104_400_mode
  • Using the best 400 mode recon from yesterday: Rec_20190103_214048.fits
  • Actuator 0216 is suspect, I keep getting warnings about PURE CURRENT
  • fastdiagn_54665 |WAR| 303271|2019-01-04 18:31:34.076356| FUNCTWARNING > FunctWarning CHFFPURECURRENT-0216 0.708915
    fastdiagn_54665 |WAR| 303272|2019-01-04 18:31:34.082853| FUNCTWARNING > FunctWarning CHFFPURECURRENT-0216 0.720054
    fastdiagn_54665 |WAR| 305989|2019-01-04 18:32:15.975421| FUNCTWARNING > FunctWarning CHFFPURECURRENT-0216 0.60668
    fastdiagn_54665 |WAR| 305991|2019-01-04 18:32:15.981743| FUNCTWARNING > FunctWarning CHCURRAVERAGE-0216 -0.8
    fastdiagn_54665 |WAR| 306047|2019-01-04 18:32:16.324815| FUNCTWARNING > FunctWarning CHFFPURECURRENT-0216 0.735929

  • Intmat: 20190104_175318
  • Recon:Rec_20190104_184723.fits
  • I don't think that I can improve on that, though the edge of the pupil is ugly as sin, but it always is for DX.
  • New Flat then on to bin 2.
  • Flat: 20190104_400_mode_2
18:58
  • Darn it: idl_54602 |INF| 1056|2019-01-04 18:58:10.156693| MAIN > Maximum mode index used to apply flat -> # 0
  • idl_54602 |INF| 1084|2019-01-04 18:59:13.287668| MAIN > Maximum mode index used to apply flat -> # 337
  • Flat: 20190104_400_mode works better.
  • idl_54602 |INF| 1168|2019-01-04 19:00:09.457108| MAIN > Maximum mode index used to apply flat -> # 634
19:01
  • Bin 2.
  • 10 mode, open loop, manually centered camera lens
  • Disturb: 20190104_190530
  • Intmat: 20190104_190610
  • Recon: Rec_20190104_190745.fits
  • Closed loop and let camera lens center up.
  • tor_54719|ERR| 1462|2019-01-04 19:09:51.807591| ALERTHANDLER > Received an ERROR alert! Forcing Failure state.
    AdSecArbitrator_54719|ERR| 1463|2019-01-04 19:09:51.807632| ALERTHANDLER > Alert message: COILS DISABLED from fastdiagn.R
  • Both AdSecs in failure, restarting both. (power hiccup, confirmed by Chris)
  • Eliot needs to get on the scope to reset a LUCI alarm.
  • sx doing a bunch of those blasted dumps, restarting it AGAIN.
19:40
  • Looks like Elliot is off of the Telescope, though nobody informed me of the fact, only that I don't see a flashlight.
  • 10 mode, closed loop.
  • Intmat:20190104_194135
  • Recon:20190104_194303
  • 36 mode: closed loop
  • Disturb:20190104_194506
  • Intmat:20190104_194135
  • Recon:20190104_194718
  • 66 mode: closed loop
  • Disturb:20190104_195025
  • Intmat:20190104_195229
  • Bad intmat
  • Intmat: 20190104_195440
  • REcon:20190104_195619
19:57
  • 153 modes, 4 iter
  • Disturb: 20190104_195838
  • Intmat:20190104_195935
  • Recon:20190104_200104
  • 153 mode, long integration
  • Intmat:20190104_200444
  • Recon:20190104_201756
  • Trying different Disturb, I used 672_0.4.fits and it had too much slope RMS, trying 672_0.3
  • Disturb: 20190104_202413
  • Intmat: 20190104_202520
  • Recon: 20190104_203812
  • Looks very good.
  • To bin 3
20:42
  • New Bin2 flat first: 20190104_153_mode
  • 10 mode open loop
  • Disturb:20190104_205550
  • Intmat:20190104_205621
  • Recon:20190104_205803
  • 10 mode closed loop:
  • Intmat:20190104_205940
  • Recon:20190104_210112
  • 36 modes:
  • Disturb: 20190104_210239
  • Intmat:20190104_210341
  • Recon:20190104_210507
  • 66 mode
  • Disturb:20190104_210643
  • Intmat:20190104_210731
  • Recon:20190104_211136
  • Again
  • Intmat:20190104_211309
  • Recon:20190104_211433
  • Now a long set:
  • Intmat:20190104_212001
  • Recon:20190104_213321
  • Looks quite good.
  • No time to do bin4 before handover, as they like to take the cube off early.

-- GregoryTaylor - 04 Jan 2019