20181116 Changing DX AdSec Configuration for NEW KL_v26 Basis Set (and back to KL_v22 Basis Set)

Step to change DX AdSec Configuration

login to AOeng@dxadsec
$ cd aoroot/config/current/TS3
$ cp bad_actuators_KL_v26.list bad_actuators.list
$ idl
IDL> adsec_make_bad_act_files
IDL> exit

=> Rest and Power off DX AdSec
=> adsc_stop
=> adsc_start
=> adsceng & etc
=> Power On and Load Programs.
=> Ready to SetFlatAO

  • To change back to KL_v22 configuration follow the same steps as above but copy the file:
$ cp bad_actuators_KL_v22.list bad_actuators.list

New Bad Actuators

  • With the KL_v26 configuration had to include act 567 in the position do-not-use list
  • Get large positive force on act 355 and large negative force on 356. Not sure which is the problem. When have a chance we should put one and then the other in the position do-not-use list and see if high forces go away.
  • Do we need to add these changes to the bad_actuators_KL_v22.list file? Wait and see.

Configureation Information

19:50 Find the "new" bad_actuator.list file that includes the repaired actuators
  • most recent bad_actuator file with replaired actuators included:
  • /home/aoeng/aoroot/conf/adsec/current/TS3/backup/bad_actuators.list.2018-10-14T19:55:52
[AOeng@dxadsec backup]$ pwd
/home/aoeng/aoroot/conf/adsec/current/TS3/backup
$ cp bad_actuators.list bad_actuators_KL_v22.list
$ cp backup/bad_actuators.list.2018-10-14T19:55:52 bad_actuators_KL_v26.list
[AOeng@dxadsec TS3]$ diff bad_actuators_KL_v22.list bad_actuators_KL_v26.list 
84,108c84,114
<    378 :  0  :  1  :  0  : 20180118 :  DLM GB : Large position reading when TS3 was first installed, 01054462 um
<    379 :  0  :  1  :  0  : 20180118 :  DLM GB : Large position reading when TS3 was first installed, 01099972 um
<    451 :  0  :  1  :  0  : 20180118 :  DLM GB : Large position reading when TS3 was first installed, 01053830 um
<    557 :  0  :  1  :  0  : 20180121 :  GB : Incorrect position, off with respect to neighbouring actuators
<    260 :  0  :  1  :  0  : 20180121 :  GB : Incorrect position, off with respect to neighbouring actuators
<    208 :  0  :  1  :  0  : 20180121 :  GB : Position is fluctuating
<     79 :  0  :  1  :  0  : 20180121 :  GB : Position is fluctuating
<    340 :  0  :  1  :  0  : 20180121 :  GB : Incorrect position, off with respect to neighbouring actuators
<    223 :  0  :  1  :  0  : 20180125 :  GB : Incorrect position, jumps to 110um with shell rested
<    455 :  0  :  1  :  0  : 20180125 :  GB : Incorrect position, 48.7um gap with neighbours at 30um with shell rested
<    479 :  0  :  1  :  0  : 20180127 :  GB : Position jumped -9 um with shell set
<     91 :  0  :  1  :  0  : 20180127 :  GB : High residual in the ff matrix data reduction of 20180129_020015
<    591 :  0  :  1  :  0  : 20180129 :  GB : Drift in position
<    187 :  0  :  1  :  0  : 20180129 :  GB : High residual in the ff matrix data reduction of 20180129_175236
<    453 :  0  :  1  :  0  : 20180202 :  DLM GB : Jump in position caused high forces
<    343 :  0  :  1  :  0  : 20180203 :  DLM : Jumped so only 125 modes applied.  Bite out of pupil at 6 oclock
<     70 :  0  :  1  :  0  : 20180204 :  GB : High residual in the ff matrix data reduction of 20180204_182402
<    376 :  0  :  1  :  0  : 20180208 :  DLM : Jumped causing a bump and high forces
<    555 :  0  :  1  :  0  : 20180208 :  DLM : Jumped causing high forces
<    449 :  0  :  1  :  0  : 20180209 :  DLM : Jumped while flattening
<    367 :  0  :  1  :  0  : 20180215 :  DLM : Jumped so high forces and only 152 modes applied in flat
<    452 :  0  :  1  :  0  : 20180226 :  GET : Force has been flutuating a bit but now it getting too large
<    218 :  0  :  1  :  0  : 20180226 :  DLM : Jumped to 100000+ um several time during several attempts to SetFlatAO
<    565 :  0  :  1  :  0  : 20180917 :  GET : Testing old IM
<    145 :  0  :  1  :  0  : 20180917 :  GET : Testing old IM
---
>   378 :  0  :  1  :  0  : 20180118 :  DLM GB : Large position reading when TS3 was first installed, 01054462 um
>   379 :  0  :  1  :  0  : 20180118 :  DLM GB : Large position reading when TS3 was first installed, 01099972 um
>   451 :  0  :  1  :  0  : 20180118 :  DLM GB : Large position reading when TS3 was first installed, 01053830 um
>   557 :  0  :  1  :  0  : 20180121 :  GB : Incorrect position, off with respect to neighbouring actuators
>   260 :  0  :  1  :  0  : 20180121 :  GB : Incorrect position, off with respect to neighbouring actuators
>   208 :  0  :  1  :  0  : 20180121 :  GB : Position is fluctuating
>    79 :  0  :  1  :  0  : 20180121 :  GB : Position is fluctuating
> #GBZ   340 :  0  :  1  :  0  : 20180121 :  GB : Incorrect position, off with respect to neighbouring actuators
>   223 :  0  :  1  :  0  : 20180125 :  GB : Incorrect position, jumps to 110um with shell rested
> #GBZ   455 :  0  :  1  :  0  : 20180125 :  GB : Incorrect position, 48.7um gap with neighbours at 30um with shell rested
> #GBZ   479 :  0  :  1  :  0  : 20180127 :  GB : Position jumped -9 um with shell set
>    91 :  0  :  1  :  0  : 20180127 :  GB : High residual in the ff matrix data reduction of 20180129_020015
>   591 :  0  :  1  :  0  : 20180129 :  GB : Drift in position
>   187 :  0  :  1  :  0  : 20180129 :  GB : High residual in the ff matrix data reduction of 20180129_175236
> #GBZ   453 :  0  :  1  :  0  : 20180202 :  DLM GB : Jump in position caused high forces
> #GBZ   343 :  0  :  1  :  0  : 20180203 :  DLM : Jumped so only 125 modes applied.  Bite out of pupil at 6 oclock
>    70 :  0  :  1  :  0  : 20180204 :  GB : High residual in the ff matrix data reduction of 20180204_182402
> #DLM  376 :  0  :  1  :  0  : 20180208 :  DLM : Jumped causing a bump and high forces
> #DLM  555 :  0  :  1  :  0  : 20180208 :  DLM : Jumped causing high forces
> #DLM  449 :  0  :  1  :  0  : 20180209 :  DLM : Jumped while flattening
> #GBZ   367 :  0  :  1  :  0  : 20180215 :  DLM : Jumped so high forces and only 152 modes applied in flat
> #GBZ   452 :  0  :  1  :  0  : 20180226 :  GET : Force has been flutuating a bit but now it getting too large
> #DLM   218 :  0  :  1  :  0  : 20180226 :  DLM : Jumped to 100000+ um several time during several attempts to SetFlatAO
>   559 :  0  :  1  :  0  : 20180821 :  GB : High residual in the ff matrix data reduction of 20180821_192630
>   604 :  0  :  1  :  0  : 20180821 :  GB : High residual in the ff matrix data reduction of 20180821_192630
>   145 :  0  :  1  :  0  : 20180831 :  DLM : Slightly high RMS during FF Matrix measurement.  Causing act around to move
>   565 :  0  :  1  :  0  : 20180911 :  DLM : Jumped in position to current bump limits the number of modes to 327
>   367 :  0  :  1  :  0  : 20181013 :  GET : Causing a bump and only 150 something modes in the flat.
> #  355 :  0  :  1  :  0  : 20181013 :  GET : Causing a bump and only 150 something modes in the flat.
> #  479 :  0  :  1  :  0  : 20181014 :  GET : Causing a bump and only 150 something modes in the flat.
> #  469 :  0  :  1  :  0  : 20181014 :  GET : Causing a bump and only 150 something modes in the flat.

20:00 Run IDL> adsec_make_bad_act_files on current file (KL_v22)
IDL> adsec_make_bad_act_files
A backup of the current file: bad_actuators.list
                     made to: ./backup/bad_actuators.list.2018-11-16T20:00:12
A backup of the current file: act_wo_curr.txt
                     made to: ./backup/act_wo_curr.txt.2018-11-16T20:00:12
A backup of the current file: act_wo_pos.txt
                     made to: ./backup/act_wo_pos.txt.2018-11-16T20:00:12
A backup of the current file: act_wo_icc.txt
                     made to: ./backup/act_wo_icc.txt.2018-11-16T20:00:12
A backup of the current file: ../processConf/fastdiagn/fastdiagn.param
                     made to: ../processConf/fastdiagn/backup/fastdiagn.param.2018-11-16T20:00:12
% Compiled module: ADSEC_WRITE_ELEC_TXT.
 
 File act_wo_curr.txt written with:
    Actuators that cannot apply current =  15
 
 File act_wo_pos.txt written with:
    Actuators that cannot read position =  25
 
 File act_wo_icc.txt written with:
          Actuators not in control loop =   2
 
% Compiled module: ADSEC_WRITE_FASTDIAGN_PARAM.
 
 File fastdiagn.param written with:
    Actuators that cannot apply current =  15
    Actuators that cannot read position =  25

20:08 Change config for KL_v26

  • [AOeng@dxadsec TS3]$ cp bad_actuators_KL_v26.list bad_actuators.list
  • idl
IDL> adsec_make_bad_act_files
A backup of the current file: bad_actuators.list
                     made to: ./backup/bad_actuators.list.2018-11-16T20:08:17
A backup of the current file: act_wo_curr.txt
                     made to: ./backup/act_wo_curr.txt.2018-11-16T20:08:17
A backup of the current file: act_wo_pos.txt
                     made to: ./backup/act_wo_pos.txt.2018-11-16T20:08:17
A backup of the current file: act_wo_icc.txt
                     made to: ./backup/act_wo_icc.txt.2018-11-16T20:08:17
A backup of the current file: ../processConf/fastdiagn/fastdiagn.param
                     made to: ../processConf/fastdiagn/backup/fastdiagn.param.2018-11-16T20:08:17
% Compiled module: ADSEC_WRITE_ELEC_TXT.
 
 File act_wo_curr.txt written with:
    Actuators that cannot apply current =  15
 
 File act_wo_pos.txt written with:
    Actuators that cannot read position =  17
 
 File act_wo_icc.txt written with:
          Actuators not in control loop =   2
 
% Compiled module: ADSEC_WRITE_FASTDIAGN_PARAM.
 
 File fastdiagn.param written with:
    Actuators that cannot apply current =  15
    Actuators that cannot read position =  17

-- DougMiller - 16 Nov 2018