DX Tests With Cal Unit

16:08
  • Waiting for telescope.

17:18
  • We have the light, everything should be ready.
  • Closed loop with Bin1, 400 modes.
  • Saved a flat: 20181030_400_flat
  • hexapod -2.41 -2.37 0.467 -216.95 -267.655 0
  • Bayside Stages: -747 -49.4 55.6
17:25
  • Closed with disturbance: /local/aomeas/adsec_calib/CMD/disturb/dist_flao1_ts4_atm_s2.0_L040.0_v15.0_ovfreq990.00_sd3892.fits
  • Datasets, with 10 luci frames: 173856, 173934
17:42
  • Moving the stages with no offloading.
  • Dataset: no disturb/with offloading 174613
  • 559 jumped in position.
  • Moved X stage to -74.1, delta forces +- 0.02
  • -74.2 +0.04 - 0.03 TT +- 2.7
  • -74.3 Forces +0.4 - 0.3 TT -4.1, +4.2 Command -4.2+4.4
  • -74.4 Forces -0.04+0.03, Positions -5.55 5.6
  • -74.5 Forces -0.06+0.05, positions -7+7 Dataset: 175756
  • -75.0 Forces +-0.06 Positions +- 13 Datasets: 180247
  • -75.3 Positions -17.4+18.4, Forces-0.8+0.07
  • back to -74, trying other axis
18.10
  • Trying the other bayside stage axis:
  • On axis dataset with PSF 181145
  • 559 is jumping:
 fastdiagn_81213 |WAR|    14979|2018-10-30 18:20:54.318237|    FUNCTWARNING > FunctWarning CHDISTRMS-0559 3.52622e-07
fastdiagn_81213 |WAR| 14981|2018-10-30 18:20:55.039929| FUNCTWARNING > FunctWarning CHDISTRMS-0559 1.37194e-07
fastdiagn_81213 |WAR| 14984|2018-10-30 18:20:55.447434| FUNCTWARNING > FunctWarning CHDISTRMS-0559 4.53642e-07
fastdiagn_81213 |WAR| 14990|2018-10-30 18:20:58.301361| FUNCTWARNING > FunctWarning CHDISTRMS-0559 1.78449e-07
fastdiagn_81213 |WAR| 14992|2018-10-30 18:20:59.556491| FUNCTWARNING > FunctWarning CHDISTRMS-0559 2.86191e-07
fastdiagn_81213 |WAR| 15002|2018-10-30 18:21:06.761485| FUNCTWARNING > FunctWarning CHDISTRMS-0559 1.61225e-07
fastdiagn_81213 |WAR| 15016|2018-10-30 18:21:20.040242| FUNCTWARNING > FunctWarning CHDISTRMS-0559 1.11726e-07
fastdiagn_81213 |WAR| 15021|2018-10-30 18:21:24.322590| FUNCTWARNING > FunctWarning CHDISTRMS-0559 4.16391e-07
fastdiagn_81213 |WAR| 15024|2018-10-30 18:21:26.048869| FUNCTWARNING > FunctWarning CHDISTRMS-0559 1.3018e-07
fastdiagn_81213 |WAR| 15031|2018-10-30 18:21:31.607782| FUNCTWARNING > FunctWarning CHDISTRMS-0559 1.31831e-07
fastdiagn_81213 |WAR| 15033|2018-10-30 18:21:32.086646| FUNCTWARNING > FunctWarning CHDISTRMS-0559 2.64823e-07
fastdiagn_81213 |WAR| 15037|2018-10-30 18:21:35.496951| FUNCTWARNING > FunctWarning CHDISTRMS-0559 1.98097e-07
fastdiagn_81213 |WAR| 15040|2018-10-30 18:21:36.721439| FUNCTWARNING > FunctWarning CHDISTRMS-0559 1.15281e-07
  • Maximum offset to -50.9 Forces -0.08+0.1, Positions -19+21
  • Dataset: 182850, 182945
19:01
  • Testing NCPA, the optical gain is 0.97, which is odd...
  • Rotator 209 Datasets: 191143
  • Rotator 0 : Dataset: 194124
  • Rotating back to 209, with TTLUT on. Will re-center the PSF
  • Dataset at 0 with TTLUT on 194629
  • Dataset back to 209, now GOPT is 1.3!!
  • Dataset: 195643
  • Now I will rotate slowly, to see if the silly TTLUT works right. It had trouble keeping things in the center, before.
  • 0.25 deg/sec Turned on AFC (LOOKUP)
20:58
  • Turning off AFC, full frame.
  • Setting the camera up so that I can see the spots on the fieldstop
  • Clear/HKspec
  • Dimmer Cal source 15 mag
  • Dark: 20181030_211737, LUCI frame 0008
  • Using script "luci_take_three.py"
  • Rotator angle 0
  • Saved tracknum: 20181030_212329
    Saved tracknum: 20181030_212353
    Saved tracknum: 20181030_212416
  • Luci Frames 9, 10, 11
21:28
  • Rotator angle 120
  • Saved tracknum: 20181030_212851
    Saved tracknum: 20181030_212915
    Saved tracknum: 20181030_212940
  • Luci Frames 12, 13, 14
  • Redo! Forgot to turn gains back on.
  • Saved tracknum: 20181030_213134
    Saved tracknum: 20181030_213158
    Saved tracknum: 20181030_213223
  • Luci Frames 15, 16, 17
21:35
  • Rotator angle 240
  • Saved tracknum: 20181030_213638
    Saved tracknum: 20181030_213703
    Saved tracknum: 20181030_213727
  • Luci Frames: 18, 19, 20
21:41
  • Rotator angle 360
  • Saved tracknum: 20181030_214205
    Saved tracknum: 20181030_214230
    Saved tracknum: 20181030_214253
  • Luci Frames 21, 22, 23
21:47
  • Rotator angle 450
  • Saved tracknum: 20181030_214725
    Saved tracknum: 20181030_214748
    Saved tracknum: 20181030_214811
  • Luci Frames: 24, 25, 26
21:52
  • Rotator Angle 300
  • Saved tracknum: 20181030_215319
    Saved tracknum: 20181030_215342
    Saved tracknum: 20181030_215409
  • Luci Frames: 27, 28, 29
21:57
  • Rotator Angle 180
  • Saved tracknum: 20181030_215809
    Saved tracknum: 20181030_215834
    Saved tracknum: 20181030_215857
  • Luci Frames: 30, 31, 32
22:03
  • Rotator Angle 60
  • Saved tracknum: 20181030_220421
    Saved tracknum: 20181030_220445
    Saved tracknum: 20181030_220509
  • Luci Frames: 33, 34, 35
22:09
  • Rotator Angle -60
  • Saved tracknum: 20181030_220941
    Saved tracknum: 20181030_221005
    Saved tracknum: 20181030_221029
  • Luci Frames: 36, 37, 38
22:11
  • Stopping. The end is nigh.
22:19
  • Disregard
  • Rotator Angle -90
  • Saved tracknum: 20181030_222124
    Saved tracknum: 20181030_222147
    Saved tracknum: 20181030_222210
  • Luci frames: 39, 40, 41
22:26
  • -30
  • Saved tracknum: 20181030_222648
    Saved tracknum: 20181030_222712
    Saved tracknum: 20181030_222736
  • Luci Frames 42, 43, 44
22:31
  • 30
  • Saved tracknum: 20181030_223124
    Saved tracknum: 20181030_223147
    Saved tracknum: 20181030_223211
  • Luci Frames 45, 46, 47
22:36
  • 90
  • Saved tracknum: 20181030_223625
    Saved tracknum: 20181030_223648
    Saved tracknum: 20181030_223711
  • Luci Frames 48, 49, 50
22:40
  • 150
  • Saved tracknum: 20181030_224054
    Saved tracknum: 20181030_224117
    Saved tracknum: 20181030_224143
  • Luci Frames: 51, 52, 53
22:46
  • 210
  • Saved tracknum: 20181030_224611
    Saved tracknum: 20181030_224634
    Saved tracknum: 20181030_224658
  • Luci Frames: 54, 55, 56
22:50
  • 270
  • Saved tracknum: 20181030_225025
    Saved tracknum: 20181030_225049
    Saved tracknum: 20181030_225111
  • Luci Frames: 57, 58, 59

-- GregoryTaylor - 30 Oct 2018
Topic revision: r4 - 30 Oct 2018, GregoryTaylor
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback