20181025_SX_Day SX 4D Alignment

16:41 Xianyu getting InterferometetCtrl process running.
  • Tested on DX. Still works
  • Xianyu is checking startup script on 4D computer. No change made.
  • Environment on sxadsec computer was not correct. Xianyu change it. Now works.
  • Xianyu says dxadsec environment was not correct either, but close enough to work.
    • Email from Xianyu
The following line was added in SX AdSec flao_environment.sh to run the 4D InterfermeterCtrl. Thanks.
export PYRO_CONFIG_FILE=$ADOPT_ROOT/conf/adsec/current/processConf/Pyro_Client.conf

Cheers,
Xianyu

16:54 Collimate M2 and M3 to yesterday's values
  • See a bit of light

17:13 Move selector axis, No improvement either direction

18:00 Move M3 Tip by -40 and tilt by -60 and align with M2 hexapod
  • Looks good
  • New detector mask 20181025_180000
  • SX M2 Hexapod Position for 4D:
    M2_1.jpg
  • SX M3 Hexapod Position for 4D:
    M3_1.jpg

18:15 Start Hexapod IM measurement
  • IDL> print, hexapod_opt_calib()
  • /local/aomeas/adsec_calib/hexapod/20181025_183422/

18:35 Align hexapod x 2
  • IDL> print, hexalign(/apply)
  • IDL> print, hexalign(/apply)
  • SX M2 Hexapod Position for 4D Aligned:
    M2_aligned_2.jpg
  • SX 4D initial flat rms: low order removed, 77 nm rms
    4D_initial_flat.jpg 4D_initial_rms.jpg

18:34 Start flattening
  • AdOpt> print, i4d_opt_intmat(0,40,AMPRMS=250e-9)
    • 20181025_184314
  • No trigger so 4D did not collect data set

19:40 Leroy is checking SX AdSec BCU fiber to 4D tigger box
  • Test is successful. Tigger works!

20:00 Collect Flattening data: 40 modes
  • AdOpt> print, i4d_opt_intmat(0,40,AMPRMS=250e-9)
    • 20181025_200008
  • comm4d.produce('20181025_200008')
  • IDL> print, if_redux(/MODAL, '20181025_200008')
  • IDL> print, build_int_mat(['20181025_200008'])
  • AdOpt> print, opt_int_mat_reduce2(40, track='20181025_200008')
    • /local/aomeas/adsec_calib/flat/20181025_201601/flattening_result.sav
  • SX 4D 40 mode flat rms: low order removed, 92 nm rms
    4D_40_flat_rms.jpg

20:21 Flattening: 41-100 modes
  • AdOpt>print, i4d_opt_intmat(41,100,AMPRMS=250e-9)
    • 20181025_202114
  • comm4d.produce('20181025_202114')
  • IDL> print, if_redux(/MODAL, '20181025_202114')
  • IDL> print, build_int_mat(['20181025_200008','20181025_202114'])
  • AdOpt> print, opt_int_mat_reduce2(100, track='20181025_200008')
    • /local/aomeas/adsec_calib/flat/20181025_203431/flattening_result.sav
  • SX 4D 100 mode flat rms: low order removed, 64 nm rms
    4D_100_flat_rms.jpg

20:36 Flattening: 101-200 modes
  • AdOpt>print, i4d_opt_intmat(41,100,AMPRMS=100e-9)
    • 20181025_203625
  • comm4d.produce('20181025_203625')
  • IDL> print, if_redux(/MODAL, '20181025_203625')
  • IDL> print, build_int_mat(['20181025_200008','20181025_202114','20181025_203625'])
  • IDL> print, hexalign(/apply)
  • AdOpt> print, opt_int_mat_reduce2(200, track='20181025_200008')
    • /local/aomeas/adsec_calib/flat/20181025_210107/flattening_result.sav
  • SX 4D 200 mode flat rms: low order removed, 56 nm rms
    4D_200_flat_rms.jpg

21:02 Flattening: 201-400 modes
  • AdOpt> print, i4d_opt_intmat(201,400)
    • 20181025_210215
  • IDL> print, if_redux(/MODAL, '20181025_210215')
  • IDL> print, build_int_mat(['20181025_200008','20181025_202114','20181025_203625','20181025_210215'])
  • IDL> print, hexalign(/apply)
  • AdOpt> print, opt_int_mat_reduce2(400, track='20181025_200008') (Bruce still on telescope. May have been extra vibrations)
    • /local/aomeas/adsec_calib/flat/20181025_213523/flattening_result.sav
  • SX 4D 400 mode flat rms: low order removed, 44 nm rms
    4D_400_flat_rms.jpg
  • AdOpt> print, opt_int_mat_reduce2(400, track='20181025_200008')
    • /local/aomeas/adsec_calib/flat/20181025_215225/flattening_result.sav
  • SX 4D 400 mode flat_2 rms: low order removed, 47 nm rms
    4D_400_2_flat_rms.jpg 4D_400_flat_forces.jpg

21:15 Bruce had to get into the Mirror Cell. Most of the 30 minutes I was processing data. Had to maybe wait 10 minutes. Done.

21:48 Flattening: 401-600 modes
  • AdOpt> print, i4d_opt_intmat(401,600)
    • 20181025_214852
  • IDL> print, if_redux(/MODAL, '20181025_214852')
  • IDL> print, build_int_mat(['20181025_200008','20181025_202114','20181025_203625','20181025_210215','20181025_214852'])
  • IDL> print, hexalign(/apply)
  • AdOpt> print, opt_int_mat_reduce2(600, track='20181025_200008')
    • /local/aomeas/adsec_calib/flat/20181025_222441/flattening_result.sav
    • High forces (-0.366, 0.426)
  • SX 4D 600 mode flat forces:
    4D_600_flat_forces.jpg 4D_600_flat_rms.jpg

22:22 Noise Measurement
  • 20181025_222200_noise 1000 frames

22:30 Flattening: 601-649 modes
  • AdOpt> print, i4d_opt_intmat(601,649)
    • 20181025_223021
  • IDL> print, if_redux(/MODAL, '20181025_223021')
  • IDL> print, build_int_mat(['20181025_200008','20181025_202114','20181025_203625','20181025_210215','20181025_214852','20181025_223021'])
  • IDL> print, hexalign(/apply)

22:39 Flatten with 500 modes
  • AdOpt> print, opt_int_mat_reduce2(500, track='20181025_200008')
    • /local/aomeas/adsec_calib/flat/20181025_223944/flattening_result.sav
  • SX 4D 500 mode flat forces:
    4D_500_flat_forces.jpg 4D_500_flat_rms.jpg 4D_500_flat.jpg

  • AdOpt> print, opt_int_mat_reduce2(649, track='20181025_200008')
    • /local/aomeas/adsec_calib/flat/20181025_224735/flattening_result.sav
  • AdOpt> print, opt_int_mat_reduce2(649, track='20181025_200008')
    • /local/aomeas/adsec_calib/flat/20181025_225534/flattening_result.sav
  • SX 4D 649 mode flat forces:
    4D_649_flat_2.jpg 4D_649_flat_2_rms.jpg 4D_649_flat_2_forces.jpg
  • Applied flat /local/aomeas/adsec_calib/flat/20181025_225534/flattening_result.sav
    • images _applied
  • SX 4D 649 mode flat applied:
    4D_649_flat_2_applied.jpg 4D_649_flat_2_rms_applied.jpg 4D_649_flat_2_forces_applied.jpg

23:04 Noise Measurement
  • 20181025_230400_noise 1000 frames

-- DougMiller - 25 Oct 2018
I Attachment Action Size Date Who Comment
4D_100_flat_rms.jpgjpg 4D_100_flat_rms.jpg manage 125 K 25 Oct 2018 - 21:20 DougMiller SX 4D 100 mode flat rms
4D_200_flat_rms.jpgjpg 4D_200_flat_rms.jpg manage 131 K 25 Oct 2018 - 21:21 DougMiller SX 4D 200 mode flat rms
4D_400_2_flat_rms.jpgjpg 4D_400_2_flat_rms.jpg manage 137 K 25 Oct 2018 - 21:58 DougMiller SX 4D 400 mode flat_2 rms
4D_400_flat_forces.jpgjpg 4D_400_flat_forces.jpg manage 115 K 26 Oct 2018 - 18:43 DougMiller SX 4D 400 mode flat forces
4D_400_flat_rms.jpgjpg 4D_400_flat_rms.jpg manage 141 K 25 Oct 2018 - 21:57 DougMiller SX 4D 400 mode flat rms
4D_40_flat_rms.jpgjpg 4D_40_flat_rms.jpg manage 107 K 25 Oct 2018 - 21:19 DougMiller SX 4D 40 mode flat rms
4D_500_flat.jpgjpg 4D_500_flat.jpg manage 93 K 26 Oct 2018 - 18:45 DougMiller SX 4D 500 mode flat
4D_500_flat_forces.jpgjpg 4D_500_flat_forces.jpg manage 114 K 26 Oct 2018 - 18:44 DougMiller SX 4D 500 mode flat forces
4D_500_flat_rms.jpgjpg 4D_500_flat_rms.jpg manage 140 K 26 Oct 2018 - 18:44 DougMiller SX 4D 500 mode flat rms
4D_600_flat_forces.jpgjpg 4D_600_flat_forces.jpg manage 162 K 26 Oct 2018 - 18:46 DougMiller SX 4D 600 mode flat forces
4D_600_flat_rms.jpgjpg 4D_600_flat_rms.jpg manage 154 K 26 Oct 2018 - 18:46 DougMiller SX 4D 600 mode flat rms
4D_649_flat_2.jpgjpg 4D_649_flat_2.jpg manage 91 K 26 Oct 2018 - 18:52 DougMiller SX 4D 649 mode flat
4D_649_flat_2_applied.jpgjpg 4D_649_flat_2_applied.jpg manage 93 K 26 Oct 2018 - 18:54 DougMiller SX 4D 649 mode flat applied
4D_649_flat_2_forces.jpgjpg 4D_649_flat_2_forces.jpg manage 96 K 26 Oct 2018 - 18:53 DougMiller SX 4D 649 mode flat forces
4D_649_flat_2_forces_applied.jpgjpg 4D_649_flat_2_forces_applied.jpg manage 95 K 26 Oct 2018 - 18:55 DougMiller sx 4D 649 mode flat forces applied
4D_649_flat_2_rms.jpgjpg 4D_649_flat_2_rms.jpg manage 157 K 26 Oct 2018 - 18:53 DougMiller SX 4D 649 mode flat rms
4D_649_flat_2_rms_applied.jpgjpg 4D_649_flat_2_rms_applied.jpg manage 150 K 26 Oct 2018 - 18:54 DougMiller SX 4D 649 mode flat rms applied
4D_649_flat_forces.jpgjpg 4D_649_flat_forces.jpg manage 97 K 26 Oct 2018 - 18:48 DougMiller SX 4D 649 mode flat forces
4D_initial_flat.jpgjpg 4D_initial_flat.jpg manage 82 K 25 Oct 2018 - 19:58 DougMiller SX 4D Initial Flat
4D_initial_rms.jpgjpg 4D_initial_rms.jpg manage 112 K 25 Oct 2018 - 21:21 DougMiller SX 4D initial flat rms
M2_1.jpgjpg M2_1.jpg manage 28 K 25 Oct 2018 - 18:34 DougMiller SX M2 Hexapod Position for 4D
M2_aligned_2.jpgjpg M2_aligned_2.jpg manage 27 K 25 Oct 2018 - 19:58 DougMiller SX M2 Hexapod Position for 4D Aligned
M3_1.jpgjpg M3_1.jpg manage 74 K 25 Oct 2018 - 18:35 DougMiller SX M3 Hexapod Position for 4D
Topic revision: r5 - 26 Oct 2018, DougMiller
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback