DX Reconstructors
  • Looks like everything is setup, I have the light.
  • Can't close the loop with the old, 12 mode reconstructor and the new actuator map, so we're starting from scratch.
  • Hexapod: -0.68 1.2 1.2 -376 -172
  • Baysides: -74 -48 52.1
  • Cube: -2.2 22.360
16:55
  • Starting Open Loop
  • Intmat Disturb
  • KL_v26, 10 mode, open loop
  • Had to copy the files for creating a disturbance files from KL_v22
  • Disturb: 20181013_174614
  • Intmat: 175504
  • Recon: 175940
  • Something wrong with that last disturbance, this reconstructor doesn't do anything.
  • Disturb: 180219
  • Intmat 181441
  • Recon: 181718
  • Not enough amplitude in the disturbance.
  • Re-trying 672_0.7.fits
  • Disturb:182008
  • Intmat: 182054
  • Recon: 182324
  • A little bit better.
  • Flat: 20181013_10mode_flat1
  • Now in closed loop
  • Intmat: 182738
  • Recon: 182907
18:31
  • Still trying to get a complete pupil, moved the stages a bit.
  • Still 10 modes.
  • Open Loop
  • Disturb: 183256
  • Intmat: 183457
  • Recon: 183659
  • Closed loop
  • Intmat: 183912
  • Recon: 184201
18:42
  • Going to try 36 modes:
  • Optimized_amano_6l
  • Disturb: 184508
  • Intmat: 184603
  • Recon: 184745
  • New Flat: 20181013_63_mode (typo, but that's the real name)
18:50
  • 66 modes:
  • Disturb: 185108
  • Intmat: 185204
  • Recon: 185351
  • New Flat: 20181013_66_mode
18:56
  • 153 modes:
  • Disturb: 185656
  • Intmat: 185832
  • Recon: 190011
  • New Flat: 20181013_153_mode
19:04
  • 400 modes
  • Disturb: 190540
  • Intmat: 190619
  • Recon: 190751
  • Unstable!
  • New_flat at 100hz 12 l/d: 20181013_153_mode2
  • New Disturb: 191838
  • Intmat:192019
  • Recon: 192515
  • stable, but missing light on the bottom of the pupil
19:29
  • Trying to get some light in the bottom of the pupil
  • 10 modes starting from the flat: 20180828_400_better_1, it has light on the bottom of the pupil
  • Intmat: 193617
  • Recon: 193829
  • 36 modes:
  • Disturb 184508
  • Intmat: 094027
  • Recon 194201
  • 66 mode
  • Disturb: 194349
  • Intmat: 194508
  • Recon: 194636
  • 153 modes with a huge disturb optimize 6l per 3
  • Disturb: 194849
  • Intmat: 194924
  • Recon: 195107
  • REpeat:66 mode open loop, to try and get light in the bottom.
  • Intmat: 195515
  • Recon: 195652
  • Trying 10 modes from a different flat, again.
  • Intmat: 200154
  • Recon: 200321
  • 36 Mode
  • Disturb: 200516
  • Intmat: 200556
  • REcon: 200721
  • 66 Mode
  • Disturb: 201029
  • Intmat: 201115
  • Recon: 201312
  • 153 Mode:
  • Disturb: 201602
  • Intmat: 201646
  • Recon: 201848
  • 20181013_153_mode3
  • repeat acquisition
  • Intmat: 201848
  • Recon: 202504
  • Try 400?
  • Disturb: 203216
  • Intmat: 203256
  • Recon: 203428
  • Bad
20:36
  • Removed #367 from position, now we have light in the bad section.
  • Retry 400
  • Intmat: 204824
  • Recon: 205015
20:58
  • intmat: 205729
  • REcon: 205904
  • 20181013_400_mode3
-- GregoryTaylor - 13 Oct 2018
Topic revision: r3 - 13 Oct 2018, GregoryTaylor
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.