26 September 2018 KL Basis set with 20180829 data /w vibrations

Comparison of Peak Force and Fitting Errors for KL_v16, KL_v22 and new IF Data (Aug. 2018)

  • Peak Force Comparison:
    peak.all.jpg
  • Fitting Errors Comparison:
    errors.all.jpg

Data from 20130831 KL_v16

  • $ kl_process_single.csh
  • $ ./peak.old
  • Best Peak Force 20130831_fittedKLs_05
    • Peak Force from 20130831:
      peak.20130831_05.jpg

Data from 20180209 KL_v22

  • IDL> restore, '/local/aomeas/adsec_calib/if_functions/20180209_mirmodes/klf_object.sav', /v
  • IDL> klf->check_fitting
    • Peak Force, Fitting Error for "old" data from 9 February 2018:
      fitting_error.jpg peak_force.jpg

Data from 20180829

17:02 Start KL analysis
  • @startup
TN5=['20180829_114800','20180829_115023','20180829_115247','20180829_105335','20180829_120012','20180829_120227','20180829_120434','20180829_120540','20180829_120647','20180829_120805','20180829_120913','20180829_121022','20180829_121135','20180829_111038','20180829_121530','20180829_121641','20180829_121803','20180829_121911','20180829_122024','20180829_122146','20180829_122259','20180829_122447','20180829_122556','20180829_122717','20180829_122815','20180829_122901','20180829_123011','20180829_123119','20180829_123315','20180829_123422','20180829_123534','20180829_123638','20180829_123743','20180829_123855','20180829_124036','20180829_124151','20180829_124255','20180829_124359','20180829_124500','20180829_124607']
  • IDL> mm=obj_new('mirmodes', TN5)
  • IDL> mm->summary_opds
tracknum 		 nn 	 amp [nm] 	 first 	  last 	 missing    sampling
20180829_105335 	 35 	  150.0 	 20 	 37 	 0 	 990 x 1002
20180829_111038 	 35 	   70.0 	 200 	 217 	 0 	 990 x 1002
20180829_114800 	 125 	  500.0 	 0 	 4 	 0 	 990 x 1002
20180829_115023 	 125 	  350.0 	 5 	 9 	 0 	 990 x 1002
20180829_115247 	 51 	  250.0 	 10 	 19 	 0 	 990 x 1002
20180829_120012 	 35 	  150.0 	 38 	 55 	 0 	 990 x 1002
20180829_120227 	 35 	  150.0 	 56 	 73 	 0 	 990 x 1002
20180829_120434 	 35 	  150.0 	 74 	 91 	 0 	 990 x 1002
20180829_120540 	 35 	  100.0 	 92 	 109 	 0 	 990 x 1002
20180829_120647 	 35 	  100.0 	 110 	 127 	 0 	 990 x 1002
20180829_120805 	 35 	   80.0 	 128 	 145 	 0 	 990 x 1002
20180829_120913 	 35 	   80.0 	 146 	 163 	 0 	 990 x 1002
20180829_121022 	 35 	   80.0 	 164 	 181 	 0 	 990 x 1002
20180829_121135 	 35 	   80.0 	 182 	 199 	 0 	 990 x 1002
20180829_121530 	 35 	   50.0 	 218 	 235 	 0 	 990 x 1002
20180829_121641 	 35 	   50.0 	 236 	 253 	 0 	 990 x 1002
20180829_121803 	 35 	   50.0 	 254 	 271 	 0 	 990 x 1002
20180829_121911 	 35 	   50.0 	 272 	 289 	 0 	 990 x 1002
20180829_122024 	 35 	   50.0 	 272 	 289 	 0 	 990 x 1002
20180829_122146 	 35 	   40.0 	 290 	 307 	 0 	 990 x 1002
20180829_122259 	 35 	   40.0 	 308 	 325 	 0 	 990 x 1002
20180829_122447 	 35 	   40.0 	 326 	 343 	 0 	 990 x 1002
20180829_122556 	 35 	   40.0 	 344 	 361 	 0 	 990 x 1002
20180829_122717 	 35 	   40.0 	 362 	 370 	 0 	 990 x 1002
20180829_122815 	 35 	   40.0 	 371 	 379 	 0 	 990 x 1002
20180829_122901 	 35 	   40.0 	 380 	 397 	 0 	 990 x 1002
20180829_123011 	 35 	   40.0 	 398 	 415 	 0 	 990 x 1002
20180829_123119 	 35 	   40.0 	 416 	 433 	 0 	 990 x 1002
20180829_123315 	 35 	   40.0 	 434 	 451 	 0 	 990 x 1002
20180829_123422 	 35 	   40.0 	 452 	 469 	 0 	 990 x 1002
20180829_123534 	 35 	   40.0 	 470 	 487 	 0 	 990 x 1002
20180829_123638 	 35 	   40.0 	 488 	 505 	 0 	 990 x 1002
20180829_123743 	 35 	   40.0 	 506 	 523 	 0 	 990 x 1002
20180829_123855 	 35 	   40.0 	 524 	 541 	 0 	 990 x 1002
20180829_124036 	 35 	   40.0 	 542 	 559 	 0 	 990 x 1002
20180829_124151 	 35 	   40.0 	 560 	 577 	 0 	 990 x 1002
20180829_124255 	 35 	   40.0 	 578 	 595 	 0 	 990 x 1002
20180829_124359 	 35 	   40.0 	 596 	 613 	 0 	 990 x 1002
20180829_124500 	 35 	   40.0 	 614 	 631 	 0 	 990 x 1002
20180829_124607 	 35 	   40.0 	 632 	 647 	 0 	 990 x 1002
  • IDL> mm->collect_opds
  • IDL> mm->mask_calibration, /SHOW
    • Mask Images:
      fit_union.jpg my_union.jpg union_intersect.jpg valid_points.jpg
  • IDL> mm->produce_ifmat
  • IDL> mm->check_noise
    • Noise Plots:
      surf_rms.jpg surf.jpg
  • IDL> mm->inv_ifmat
    • Inverting Mirror Mode Matrix:
      single_values.jpg last_eigenmode.jpg
  • IDL> save, mm, file='/local/aomeas/adsec_calib/if_functions/20180829_mirmodes/mm_1.sav'

Outer = 0.29, Inner = 0.29

  • IDL> mm->interactive_tweak_mask
    • Outer=0.29, Inner=0.29
    • intersect_gmask_rebin_good.29.29.sav
    • Tweaked Masks:
      outer_mask.jpg inner_mask.jpg
  • IDL> mm->tweak_ifmat, 'good.29.29'
  • IDL> mm->inv_ifmat, mask_id='good.29.29'
  • IDL> save, mm, file='/local/aomeas/adsec_calib/if_functions/20180829_mirmodes/mm_.29.29.sav'
  • IDL> klf = obj_new('klfit', mm, 'good.29.29')
  • IDL> klf->create_theo_kls
  • IDL> klf->create_ortho_fitted_kls
  • IDL> klf->check_fitting
    • KL Modes fitting error and peak force 0.29, 0.29:
      fitting_error.29.29.jpg peak_force.29.29.jpg

Outer = 0.29, Inner = 0.98

  • IDL> restore, '/local/aomeas/adsec_calib/if_functions/20180829_mirmodes/mm_1.sav', /v
  • IDL> mm->interactive_tweak_mask
    • Outer=0.29, Inner=0.98
    • intersect_gmask_rebin_.29.98.sav
  • IDL> mm->tweak_ifmat, '.29.98'
  • IDL> mm->inv_ifmat, mask_id='.29.98'
  • IDL> save, mm, file='/local/aomeas/adsec_calib/if_functions/20180829_mirmodes/mm_.29.98.sav'
  • IDL> klf = obj_new('klfit', mm, '.29.98')
  • IDL> klf->create_theo_kls
  • IDL> klf->create_ortho_fitted_kls
  • IDL> save, klf, file='/local/aomeas/adsec_calib/if_functions/20180829_mirmodes/klf.29.98.sav'
  • IDL> klf->check_fitting
    • KL Modes fitting error and peak force 0.29, 0.98:
      fitting_error.29.98.jpg peak_force.29.98.jpg

Outer = 1.0, Inner = 0.29

  • IDL> restore, '/local/aomeas/adsec_calib/if_functions/20180829_mirmodes/mm_1.sav', /v
  • IDL> mm->interactive_tweak_mask
    • Outer=1.0, Inner=0.29
    • intersect_gmask_rebin_1.0.29.sav
  • IDL> mm->tweak_ifmat, '1.0.29'
  • IDL> mm->inv_ifmat, mask_id='1.0.29'
  • IDL> save, mm, file='/local/aomeas/adsec_calib/if_functions/20180829_mirmodes/mm_1.0.29.sav'
  • IDL> klf = obj_new('klfit', mm, '1.0.29')
  • IDL> klf->create_theo_kls
  • IDL> klf->create_ortho_fitted_kls
  • IDL> klf->check_fitting
    • Peak Force, Fitting Error for 1.0, 0.29:
      fitting_error.1.0.29.jpg peak_force.1.0.29.jpg

Tweaked Mask oc=0.12

  • IDL> restore, '/local/aomeas/adsec_calib/if_functions/20180829_mirmodes/mm_1.sav', /v
  • IDL> mm->tweak_mask, 'oc_0.12', oc=0.12
    • intersect_gmask_rebin_oc_oc_12.sav
    • Tweaked Mask with inner diameter oc=0.12:
      tweaked_mask_oc_0.12.jpg
  • IDL> mm->tweak_ifmat, 'oc_0.12'
  • IDL> mm->inv_ifmat, mask_id='oc_0.12'
  • IDL> save, mm, file='/local/aomeas/adsec_calib/if_functions/20180829_mirmodes/mm_oc_0.12.sav'
  • IDL> klf = obj_new('klfit', mm, 'oc_0.12')
  • IDL> klf->create_theo_kls
  • IDL> klf->create_ortho_fitted_kls
  • IDL> save, klf, file='/local/aomeas/adsec_calib/if_functions/20180829_mirmodes/klf.oc_0.12.sav'
  • IDL> klf->check_fitting
    • Peak Force, Fitting Error for oc=0.12:
      fitting_error.oc_0.12.jpg peak_force.oc_0.12.jpg

Tweaked Mask radmax=0.99

  • IDL> restore, '/local/aomeas/adsec_calib/if_functions/20180829_mirmodes/mm_1.sav', /v
  • IDL> mm->tweak_mask, 'radmax_0.99', radmax=0.99 (default = 0.999)
    • intersect_gmask_rebin_radmax_0.99.sav
    • Tweaked Mask with outer diameter radmax_0.99:
    • Mask with radmax=0.99:
      tweaked_mask_radmax_0.99.jpg
  • IDL> mm->tweak_ifmat, 'radmax_0.99'
  • IDL> mm->inv_ifmat, mask_id='radmax_0.99'
  • IDL> save, mm, file='/local/aomeas/adsec_calib/if_functions/20180829_mirmodes/mm_radmax_0.99.sav'
  • IDL> klf = obj_new('klfit', mm, 'radmax_0.99')
  • IDL> klf->create_theo_kls
  • IDL> klf->create_ortho_fitted_kls
  • IDL> save, klf, file='/local/aomeas/adsec_calib/if_functions/20180829_mirmodes/klf.radmax_0.99.sav'
  • IDL> klf->check_fitting
    • Peak Force, Fitting Error for radmax=0.99:
      fitting_error.radmax_0.99.jpg peak_force.radmax_0.99.jpg

Tweaked Mask oc=0.12, radmax=0.99

  • IDL> restore, '/local/aomeas/adsec_calib/if_functions/20180829_mirmodes/mm_1.sav', /v
  • IDL> mm->tweak_mask, '.99.12', radmax=0.99, oc=0.12
    • intersect_gmask_rebin_radmax_.99.12.sav
    • Tweaked Mask with inner diameter oc=0.12, radmax=0.99:
      tweaked_mask_.99.12.jpg
  • IDL> mm->tweak_ifmat, '.99.12'
  • IDL> mm->inv_ifmat, mask_id='.99.12'
  • IDL> save, mm, file='/local/aomeas/adsec_calib/if_functions/20180829_mirmodes/mm.99.12.sav'
  • IDL> klf = obj_new('klfit', mm, '.99.12')
  • IDL> klf->create_theo_kls
  • IDL> klf->create_ortho_fitted_kls
  • IDL> save, klf, file='/local/aomeas/adsec_calib/if_functions/20180829_mirmodes/klf.99.12.sav'
  • IDL> klf->check_fitting
    • Peak Force, Fitting Error for 0.99, 0.12:
      fitting_error.99.12.jpg peak_force.99.12.jpg

Outer = 0.19, Inner = 0.29

  • IDL> restore, '/local/aomeas/adsec_calib/if_functions/20180829_mirmodes/mm_1.sav', /v
  • IDL> mm->interactive_tweak_mask
    • Outer=0.19, Inner=0.19
    • intersect_gmask_rebin_.19.29.sav
  • IDL> mm->tweak_ifmat, '.19.29'
  • IDL> mm->inv_ifmat, mask_id='.19.29'
  • IDL> save, mm, file='/local/aomeas/adsec_calib/if_functions/20180829_mirmodes/mm.19.29.sav'
  • IDL> klf = obj_new('klfit', mm, '.19.29')
  • IDL> klf->create_theo_kls
  • IDL> klf->create_ortho_fitted_kls
  • IDL> klf->check_fitting
    • Peak Force, Fitting Error for 0.19, 0.29:
      fitting_error.19.29.jpg peak_force.19.29.jpg

Outer = 0.19, Inner = 0.29

  • IDL> restore, '/local/aomeas/adsec_calib/if_functions/20180829_mirmodes/mm.19.29.sav', /v
  • IDL> klf = obj_new('klfit', mm, '.19.29')
  • IDL> klf->create_theo_kls
  • IDL> klf->create_ortho_fitted_kls, klmax=647
  • IDL> klf->check_fitting

Data from 20180912

22:23 Start KL analysis
  • @startup
IDL> TN=['20180912_022930','20180912_023204','20180912_023410','20180912_023548','20180912_023823','20180912_024037','20180912_024314','20180912_024423','20180912_024545','20180912_024659','20180912_024818','20180912_024937','20180912_025043','20180912_025330','20180912_025504','20180912_025606','20180912_025705','20180912_025808','20180912_025916','20180912_030026','20180912_030432','20180912_030539','20180912_030642','20180912_030742','20180912_030843','20180912_031001','20180912_031108','20180912_031419','20180912_031517','20180912_031616','20180912_031718','20180912_031816','20180912_031941','20180912_032148','20180912_032304','20180912_032359','20180912_032504','20180912_032600','20180912_032706']
  • IDL> mm=obj_new('mirmodes', TN)
  • IDL> mm->summary_opds
tracknum 		 nn 	 amp [nm] 	 first 	  last 	 missing    sampling
20180912_022930 	 125 	  500.0 	 0 	 4 	 0 	 990 x 1002
20180912_023204 	 125 	  350.0 	 5 	 9 	 0 	 990 x 1002
20180912_023410 	 51 	  250.0 	 10 	 19 	 0 	 990 x 1002
20180912_023548 	 35 	  150.0 	 20 	 37 	 0 	 990 x 1002
20180912_023823 	 35 	  150.0 	 38 	 55 	 0 	 990 x 1002
20180912_024037 	 35 	  150.0 	 56 	 73 	 0 	 990 x 1002
20180912_024314 	 35 	  150.0 	 74 	 91 	 0 	 990 x 1002
20180912_024423 	 35 	  100.0 	 92 	 109 	 0 	 990 x 1002
20180912_024545 	 35 	  100.0 	 110 	 127 	 0 	 990 x 1002
20180912_024659 	 35 	   80.0 	 128 	 145 	 0 	 990 x 1002
20180912_024818 	 35 	   80.0 	 146 	 163 	 0 	 990 x 1002
20180912_024937 	 35 	   80.0 	 164 	 181 	 0 	 990 x 1002
20180912_025043 	 35 	   80.0 	 182 	 199 	 0 	 990 x 1002
20180912_025330 	 35 	   70.0 	 200 	 217 	 0 	 990 x 1002
20180912_025504 	 35 	   50.0 	 218 	 235 	 0 	 990 x 1002
20180912_025606 	 35 	   50.0 	 236 	 253 	 0 	 990 x 1002
20180912_025705 	 35 	   50.0 	 254 	 271 	 0 	 990 x 1002
20180912_025808 	 35 	   50.0 	 272 	 289 	 0 	 990 x 1002
20180912_025916 	 35 	   40.0 	 290 	 307 	 0 	 990 x 1002
20180912_030026 	 35 	   40.0 	 308 	 325 	 0 	 990 x 1002
20180912_030432 	 35 	   40.0 	 326 	 343 	 0 	 990 x 1002
20180912_030539 	 35 	   40.0 	 344 	 361 	 0 	 990 x 1002
20180912_030642 	 35 	   40.0 	 362 	 370 	 0 	 990 x 1002
20180912_030742 	 35 	   40.0 	 371 	 379 	 0 	 990 x 1002
20180912_030843 	 35 	   40.0 	 380 	 397 	 0 	 990 x 1002
20180912_031001 	 35 	   40.0 	 398 	 415 	 0 	 990 x 1002
20180912_031108 	 35 	   40.0 	 416 	 433 	 0 	 990 x 1002
20180912_031419 	 35 	   40.0 	 434 	 451 	 0 	 990 x 1002
20180912_031517 	 35 	   40.0 	 452 	 469 	 0 	 990 x 1002
20180912_031616 	 35 	   40.0 	 470 	 487 	 0 	 990 x 1002
20180912_031718 	 35 	   40.0 	 488 	 505 	 0 	 990 x 1002
20180912_031816 	 35 	   40.0 	 506 	 523 	 0 	 990 x 1002
20180912_031941 	 35 	   40.0 	 524 	 541 	 0 	 990 x 1002
20180912_032148 	 35 	   40.0 	 542 	 559 	 0 	 990 x 1002
20180912_032304 	 35 	   40.0 	 560 	 577 	 0 	 990 x 1002
20180912_032359 	 35 	   40.0 	 578 	 595 	 0 	 990 x 1002
20180912_032504 	 35 	   40.0 	 596 	 613 	 0 	 990 x 1002
20180912_032600 	 35 	   40.0 	 614 	 631 	 0 	 990 x 1002
20180912_032706 	 35 	   40.0 	 632 	 645 	 0 	 990 x 1002
  • IDL> mm->collect_opds
  • IDL> mm->mask_calibration, /SHOW
    • Mask Images:
      fit_union.20180912.jpg my_union.20180912.jpg valid_points.20180912.jpg union_intersect.20180912.jpg
  • IDL> mm->produce_ifmat
  • IDL> mm->check_noise
    • Noise Plots 20180912:
      surf.20180912.jpg surf_rms.20180912.jpg
  • IDL> mm->inv_ifmat
    • Inverting Mirror Mode Matrix 20180912:
      single_values.20180912.jpg last_eigenmode.20180912.jpg
  • IDL> save, mm, file='/local/aomeas/adsec_calib/if_functions/20180912_mirmodes/mm_1.sav'

Outer = 0.29, Inner = 0.29

* IDL> mm->interactive_tweak_mask
    • Outer=0.29, Inner=0.29
    • intersect_gmask_rebin_.29.29.sav
  • IDL> mm->tweak_ifmat, '.29.29'
  • IDL> mm->inv_ifmat, mask_id='.29.29'
  • IDL> save, mm, file='/local/aomeas/adsec_calib/if_functions/20180912_mirmodes/mm_.29.29.sav'
  • IDL> klf = obj_new('klfit', mm, '.29.29')
  • IDL> klf->create_theo_kls
  • IDL> klf->create_ortho_fitted_kls
  • IDL> save, klf, file='/local/aomeas/adsec_calib/if_functions/20180912_mirmodes/klf.29.29.sav'
  • IDL> klf->check_fitting
    • Peak Force, Fitting Error for 0.29, 0.29:
      fitting_error.29.29.jpg peak_force.29.29.jpg

Outer = 0.29, Inner = 0.98

  • IDL> restore, '/local/aomeas/adsec_calib/if_functions/20180912_mirmodes/mm_1.sav', /v
  • IDL> mm->interactive_tweak_mask
    • Outer=0.29, Inner=0.98
    • intersect_gmask_rebin_.29.98.sav
  • IDL> mm->tweak_ifmat, '.29.98'
  • IDL> mm->inv_ifmat, mask_id='.29.98'
  • IDL> save, mm, file='/local/aomeas/adsec_calib/if_functions/20180912_mirmodes/mm_.29.98.sav'
  • IDL> klf = obj_new('klfit', mm, '.29.98')
  • IDL> klf->create_theo_kls
  • IDL> klf->create_ortho_fitted_kls
  • IDL> save, klf, file='/local/aomeas/adsec_calib/if_functions/20180912_mirmodes/klf.29.98.sav'
  • IDL> klf->check_fitting
    • Peak Force, Fitting Error for 0.29, 0.98:
      fitting_error.29.98.jpg peak_force.29.98.jpg

Outer = 0.19, Inner = 0.29

  • IDL> restore, '/local/aomeas/adsec_calib/if_functions/20180912_mirmodes/mm_1.sav', /v
  • IDL> mm->interactive_tweak_mask
    • Outer=0.19, Inner=0.29
    • intersect_gmask_rebin_.19.29.sav
  • IDL> mm->tweak_ifmat, '.19.29'
  • IDL> mm->inv_ifmat, mask_id='.19.29'
  • IDL> save, mm, file='/local/aomeas/adsec_calib/if_functions/20180912_mirmodes/mm_.19.29.sav'
  • IDL> klf = obj_new('klfit', mm, '.19.29')
  • IDL> klf->create_theo_kls
  • IDL> klf->create_ortho_fitted_kls
  • IDL> save, klf, file='/local/aomeas/adsec_calib/if_functions/20180912_mirmodes/klf.19.29.sav'
  • IDL> klf->check_fitting
    • Peak Force, Fitting Error for 0.19, 0.29:
      fitting_error.19.29.jpg peak_force.19.29.jpg

Outer = 0.19, Inner = 0.29 with 645 KL mode fit

  • IDL> restore, '/local/aomeas/adsec_calib/if_functions/20180912_mirmodes/mm_.19.29.sav', /v
  • IDL> klf = obj_new('klfit', mm, '.19.29') (This overwrites previous .19.29 data...)
  • IDL> klf->create_theo_kls
  • IDL> klf->create_ortho_fitted_kls, klmax=645
  • IDL> save, klf, file='/local/aomeas/adsec_calib/if_functions/20180912_mirmodes/klf.19.29_645.sav'
  • IDL> klf->check_fitting

-- %USERSIG{DougMiller - 2018-09-26}%

I Attachment Action Size Date Who Comment
errors.all.jpgjpg errors.all.jpg manage 196 K 04 Oct 2018 - 20:34 DougMiller Peak Force and Fitting Errors Comparison
fit_union.20180912.jpgjpg fit_union.20180912.jpg manage 75 K 26 Sep 2018 - 22:59 DougMiller Mask Images
fit_union.jpgjpg fit_union.jpg manage 73 K 26 Sep 2018 - 17:22 DougMiller Mask Images
fitting_error.1.0.29.jpgjpg fitting_error.1.0.29.jpg manage 85 K 02 Oct 2018 - 16:34 DougMiller Peak Force, Fitting Error for 1.0, 0.29
fitting_error.19.29.jpgjpg fitting_error.19.29.jpg manage 89 K 03 Oct 2018 - 16:18 DougMiller Peak Force, Fitting Error for 0.19, 0.29
fitting_error.29.29.jpgjpg fitting_error.29.29.jpg manage 86 K 02 Oct 2018 - 18:21 DougMiller Peak Force, Fitting Error for 0.29, 0.29
fitting_error.29.98.jpgjpg fitting_error.29.98.jpg manage 91 K 02 Oct 2018 - 19:00 DougMiller Peak Force, Fitting Error for 0.29, 0.98
fitting_error.99.12.jpgjpg fitting_error.99.12.jpg manage 89 K 02 Oct 2018 - 22:35 DougMiller Peak Force, Fitting Error for 0.99, 0.12
fitting_error.jpgjpg fitting_error.jpg manage 91 K 02 Oct 2018 - 22:56 DougMiller Peak Force, Fitting Error for "old" data from 9 February 2018
fitting_error.oc_0.12.jpgjpg fitting_error.oc_0.12.jpg manage 82 K 02 Oct 2018 - 18:06 DougMiller Peak Force, Fitting Error for oc=0.12
fitting_error.radmax_0.99.jpgjpg fitting_error.radmax_0.99.jpg manage 91 K 02 Oct 2018 - 18:43 DougMiller Peak Force, Fitting Error for radmax=0.99
inner_mask.jpgjpg inner_mask.jpg manage 99 K 26 Sep 2018 - 21:24 DougMiller Tweaked Masks
last_eigenmode.20180912.jpgjpg last_eigenmode.20180912.jpg manage 52 K 26 Sep 2018 - 23:33 DougMiller Single Values 20180912
last_eigenmode.jpgjpg last_eigenmode.jpg manage 48 K 26 Sep 2018 - 21:15 DougMiller Inverting Mirror Mode Matrix
my_union.20180912.jpgjpg my_union.20180912.jpg manage 70 K 26 Sep 2018 - 22:59 DougMiller Mask Images
my_union.jpgjpg my_union.jpg manage 75 K 26 Sep 2018 - 17:22 DougMiller Mask Images
outer_mask.jpgjpg outer_mask.jpg manage 93 K 26 Sep 2018 - 17:46 DougMiller Tweaked Masks
peak.20130831_05.jpgjpg peak.20130831_05.jpg manage 146 K 04 Oct 2018 - 18:56 DougMiller Peak Force from 20130831
peak.all.jpgjpg peak.all.jpg manage 220 K 04 Oct 2018 - 20:34 DougMiller Peak Force and Fitting Errors Comparison
peak_force.1.0.29.jpgjpg peak_force.1.0.29.jpg manage 86 K 02 Oct 2018 - 16:34 DougMiller Peak Force, Fitting Error for 1.0, 0.29
peak_force.19.29.jpgjpg peak_force.19.29.jpg manage 86 K 03 Oct 2018 - 16:18 DougMiller Peak Force, Fitting Error for 0.19, 0.29
peak_force.29.29.jpgjpg peak_force.29.29.jpg manage 88 K 02 Oct 2018 - 18:21 DougMiller Peak Force, Fitting Error for 0.29, 0.29
peak_force.29.98.jpgjpg peak_force.29.98.jpg manage 87 K 02 Oct 2018 - 19:00 DougMiller Peak Force, Fitting Error for 0.29, 0.98
peak_force.99.12.jpgjpg peak_force.99.12.jpg manage 87 K 02 Oct 2018 - 22:35 DougMiller Peak Force, Fitting Error for 0.99, 0.12
peak_force.jpgjpg peak_force.jpg manage 86 K 02 Oct 2018 - 22:56 DougMiller Peak Force, Fitting Error for "old" data from 9 February 2018
peak_force.oc_0.12.jpgjpg peak_force.oc_0.12.jpg manage 88 K 02 Oct 2018 - 18:06 DougMiller Peak Force, Fitting Error for oc=0.12
peak_force.radmax_0.99.jpgjpg peak_force.radmax_0.99.jpg manage 86 K 02 Oct 2018 - 18:43 DougMiller Peak Force, Fitting Error for radmax=0.99
single_values.20180912.jpgjpg single_values.20180912.jpg manage 39 K 26 Sep 2018 - 23:33 DougMiller Single Values 20180912
single_values.jpgjpg single_values.jpg manage 40 K 26 Sep 2018 - 21:15 DougMiller Inverting Mirror Mode Matrix
surf.20180912.jpgjpg surf.20180912.jpg manage 82 K 26 Sep 2018 - 23:12 DougMiller Noise Plots 20180912
surf.jpgjpg surf.jpg manage 83 K 26 Sep 2018 - 17:28 DougMiller Noise Plots
surf_rms.20180912.jpgjpg surf_rms.20180912.jpg manage 98 K 26 Sep 2018 - 23:12 DougMiller Noise Plots 20180912
surf_rms.jpgjpg surf_rms.jpg manage 98 K 26 Sep 2018 - 17:28 DougMiller Noise Plots
tweaked_mask_.99.12.jpgjpg tweaked_mask_.99.12.jpg manage 50 K 02 Oct 2018 - 18:52 DougMiller Tweaked Mask with inner diameter oc=0.12, radmax=0.99
tweaked_mask_oc_0.12.jpgjpg tweaked_mask_oc_0.12.jpg manage 46 K 02 Oct 2018 - 16:24 DougMiller Tweaked Mask with inner diameter oc=0.12
tweaked_mask_radmax_0.99.jpgjpg tweaked_mask_radmax_0.99.jpg manage 50 K 02 Oct 2018 - 18:05 DougMiller Mask with radmax=0.99
union_intersect.20180912.jpgjpg union_intersect.20180912.jpg manage 67 K 26 Sep 2018 - 22:59 DougMiller Mask Images
union_intersect.jpgjpg union_intersect.jpg manage 66 K 26 Sep 2018 - 17:22 DougMiller Mask Images
valid_points.20180912.jpgjpg valid_points.20180912.jpg manage 139 K 26 Sep 2018 - 22:59 DougMiller Mask Images