24 September 2018 Alignment of Pupil

17:00 Start moving pupil via Zero-Coma pointing changes and M3 Tip/Tilt changes

18:00 Done moving in one direction
  • M3 415.0, 144.0, 0, 56.4
  • M2 2.67, 0.424, -0.702, -246.9, 438.97, 0

19:05 Reasonable alignment
  • M2 1.60, 2.1, -0.7027, -571.8, 232.8
  • M3 606.0, 740.0, 0, 56.4

19:22 Detector Mask
  • 20180924_192200

19:23 Start flattening
  • print, i4d_opt_intmat(0,40,AMPRMS=250e-9)
    • 0-40 20180924_192629 >>> comm4d.produce('20180924_192629')
  • IDL> print, if_redux(/modal, '20180924_192629')
  • IDL> print, build_int_mat(['20180924_192629'])

20:01 Hexapod IM
  • IDL> print, hexapod_opt_calib()
  • IDL> print, hexalign(/apply)

20:09
  • print, i4d_opt_intmat(0,200,AMPRMS=100e-9)
  • 20180924_200810
  • >>> comm4c.produce('20180924_200810')
  • IDL> print, if_redux(/modal, '20180924_200810')
  • IDL> print, build_int_mat(['20180924_200810'])

20:40 Flatten
  • print, opt_int_mat_reduce2(200, track='20180924_200810')
  • /local/aomeas/adsec_calib/flat/20180924_204251/flattening_result.sav

20:43 Collect IM data
  • AdOpt> print, i4d_opt_intmat(201,400)
    • 20180924_204338
  • AdOpt> print, i4d_opt_intmat(401,600)
    • 20180924_204508
  • AdOpt> print, i4d_opt_intmat(601,646)
    • 20180924_204905

20:59
  • M2 1.5012, 2.1245, -0.6823, -573.67, 223.38, 0
  • M3 606.0, 740.0, 0, 56.407

-- %USERSIG{DougMiller - 2018-09-24}%
  • Flat with 200 modes:
    4D_flat_200_surface.jpg

  • Flat with 200 modes:
    4D_flat_200.jpg

  • M2 and M3 final positions:
    M2_final_4d.jpg

  • M2 and M3 final positions:
    M3_final_4d.jpg
I Attachment Action Size Date Who Comment
4D_flat_200.jpgjpg 4D_flat_200.jpg manage 104 K 24 Sep 2018 - 21:12 DougMiller Flat with 200 modes
4D_flat_200_surface.jpgjpg 4D_flat_200_surface.jpg manage 138 K 24 Sep 2018 - 21:12 DougMiller Flat with 200 modes
M2_final_4d.jpgjpg M2_final_4d.jpg manage 30 K 24 Sep 2018 - 21:13 DougMiller M2 and M3 final positions
M3_final_4d.jpgjpg M3_final_4d.jpg manage 190 K 24 Sep 2018 - 21:13 DougMiller M2 and M3 final positions