20180627 DX AO Checkout + INAF Science

03:10 Geno Powered on DX WFS. Bayside X Stages not homed. Walked Geno through the steps to home and move to -70

10:50 AdSec rested and in failure state while closing the loop
             MAIN > Received cmd: LoadGainTag("/local/aomeas/adsec_calib/M2C/KL/gain/g_tt_0.70_ho1_0.00_ho2_0.00.fits", 0)
AdSecArbitrator_58180|INF|       267|2018-06-28 10:50:19.233690|   COMMANDHANDLER > FSM (status: AORunning) has received command 2018 (SetGain)
AdSecArbitrator_58180|ERR|       268|2018-06-28 10:50:19.237338|              IDL > Command returns error : IDL DSP write check failed
20182806 10:50:19.2382 Alert: Warning: setGain failed or syntax error occured
AdSecArbitrator_58180|INF|       269|2018-06-28 10:50:19.241299|   COMMANDHANDLER > Command execution failed: Fsm forced to Failure
AdSecArbitrator_58180|ERR|       270|2018-06-28 10:50:19.241553|             MAIN > LoadGainTag: FATAL - IDL DSP write check failed
AdSecArbitrator_58180|ERR|       271|2018-06-28 10:50:20.164547|     ALERTHANDLER > Received an ERROR alert! Forcing Failure state.
AdSecArbitrator_58180|ERR|       272|2018-06-28 10:50:20.164603|     ALERTHANDLER > Alert message: COILS DISABLED from housekeeper.R
20182806 10:50:20.1656 Alert: Error: COILS DISABLED

-- %USERSIG{DougMiller - 2018-06-28}%