DX LUT Day 20180511

17:47
  • Found light at zenith
  • Hexapod: 1.2 1.3 6.3 -199 191 0
  • Baysides: -75 -51 52.116
  • Cube -2.2 22.245
  • Lamp 24%
  • Mag 15.4
  • New Flat: 20180511_400_90el.sav
  • Dark Luci2 0003 181854
  • Rot angle = 0

18:24 Measure bayside motion -vs- LUCI2 motion
  • X=-74.9, Y = -51.0 LUCI 7, 182702
  • Delta X
  • X=-74.4 8, 182827
  • X=-73.9, 9, 10, 11, 182954, 183030, 183054
  • X=-74.4, 12, 13, 14, 183153, 183216, 183239
  • X=-74.9, 15, 16, 17, 183328, 183353, 183419
  • X=-75.4, 18, 19, 20, 183517, 183541, 183604
  • X=-75.9, 21, 22, 23, 183710, 183733, 183756
  • X=-75.4, 24, 25, 26, 183848, 183913, 183935

18:40 Now move in Y
  • X=-74.9, Y = -51.0 LUCI 27, 28, 29, 184044, 184113, 184138
  • Delta Y
  • Y=-50.5, 30, 31, 32, 184249, 184316, 184338
  • Y=-50.0, 33, 34, 35, 184431, 184454, 184522
  • Y=-50.5, 36, 37, 38, 184618, 184650, 184715
  • Y=-51.0, 39, 40, 41, 184814, 184837, 184903
  • Y=-51.5, 42, 43, 44, 184958, 185026, 185049
  • Y=-52.0, Get vignetting of the pupils on CCD39. Reposition the Stage to -49.0

19:32 Test encoder -vs- voltage LUT
  • X=-74.9, Y=-48.2
  • TT LUT On
  • Bayside Stages On
  • LUCI 2, 3, 4, 193328, 19344, 193505 V=-0.24, 0.20
  • X=-74.4 5, 6, 7, 193701, 193729, 193754, V=1.56, 3.56
  • X=-75.4 8, 9, 10 193937, 194000, 194026, V=-2.03, -3.16

19:41 Test Y * X=-74.9, Y=-48.2
  • LUCI 11, 12, 13, 194214, 194244, 19.4307 V=-0.24, 0.20
  • Y=-47.8 14, 15, 16, 194415, 194439, 194502 V=-3.19, 1.63
  • Y=-48.7 17, 18, 19, 194622, 194645, 194713 V=3.46, -1.59
  • Y=-48.2 20, 21, 22, 194808, 194832, 194857 V=-0.23, 0.20
20:10
  • At 75 degrees elevation.
  • New Flat. 20180511_400_75el
  • Baysides: -74.9 -48.2 51.2
  • First tracknum
  • All processes disconnected!!
20:26
  • Everything is restarted
  • -90 -> 450
  • First Tracknum: 20180511_203930
  • First Luci: 0029
  • Last Tracknum: 20180511_211116
  • Last Luci: 0085
21:13
  • 450 -> -90
  • First Track num: 20180511_211626
  • First Luci Frame: 86
  • last Track num: 20180511_214836
  • last luci frame 142
22:04
  • 60 elevation
  • -90 -> 450
  • First Tracknum 20180511_221949
  • first luci frame 154
  • last Tracknum 20180511_225241
  • last luci frame 210

23:05 TT Calibration
  • bin 4, 200 Hz, Clear/HKSpec
  • bayside stage On
  • TT LUT Off
0.0 0 211, 212, 213 230600, 230636, 23??
3.0 0 214, 215, 216 230820, 230850, 230915
0.0 0 217 231008
-3.0 0 218, 219, 220 231103, 231129, 231154
0.0 0 221 231240
0.0 3.0 222, 223, 224 231338, 231403, 231430
0.0 -3.0 225, 226, 227 231606, 231639, 231704
0.0 0.0 228, 229, 230 231757, 231827, 231859