Beginning of the night tests, TT LUT testing, AO/ESM/LS data 20180504

Spent twilight doing pointing, collimating (as usual) and Ace preset + AO Telemetry/LUCI image
  • RunAO failed on SX. Communication problem from WFS to AdSec fastlink. Restarted SX WFS and check com. OK
  • RunAO successful on DX. SX primary panicked so no telemetry collected on DX.
  • Stopped and moved to Science
  • Al collected note on improvement to "Beginning of Night" instructions. He sent email

07:55 Get telescope from Al and his NS science object
  • Had to go to Zenith and Rot=341 to home SX X stage
  • David do pointing and collimation

08:10 ESM Preset
  • Preset success
  • SX RunAO Failed. CCD39 go Not Live when closing loop. Could not get to run. Pressed Operate and CCD39 came back to live

08:39 DX Give system interrupt call after preset had succeeded

08:42 ESM Preset
  • success
  • RunAO success
  • Sent 9.4, measure 12.6
  • bin 4, 400 Hz, 36 modes
  • LUCI1 75->89
  • LUCI2 78->92

09:20ish Start Seeing Limited
  • LUCI1 92
  • LUCI2 95 ->

08:49 Taking data

10:09:44 Skip frame then failure
  • recover fail

10:17 DX Center pupils fail because Diff never below .1
  • When on to check flux

10:38 Going to TT LUT
  • SX First LUCI1 110, TN 110944, Rot=368, bin3, 200 Hz, 13.5 mag, gain (2.0, 1.5, 1.5)
  • DX First LUCI2 113, TN 111152, Rot=362, bin3, 312 Hz, 13.3 mag, gain (2.0, 1.5, 1.5)
  • SX loop opened with skip frame. re-close
  • SX 132, 133, half the gain (1.0, 0.5, 0.5)
  • SX 134-> gain (2.0, 1.5, 1.5)
  • Getting stray light on pyramid at image LUCI1 138
  • Getting stray light on pyramid at image LUCI2 140
  • SX Last LUCI1 143, TN 115853
  • DX Last LUCI2 146, TN 120059
  • SX Dark LUCI1 144, TN 120121 rot=333
  • DX Dark LUCI2, 147, TN 120335 rot=328
  • Last El 71

12:05 Get a new error when I Rested DX shell. Had previously had skip frame and so I clicked Open Loop on the WFS Control GUI. Not sure if Shell was Set or Rested when I clicked the Rest button on the AdSec Control GUI. However, but button was available so implies Shell was Set.

idl_130217         |INF|      1669|2018-05-05 12:05:37.066133|   MAIN > Safe skip thresholds successfully set.
idl_130217         |INF|      1670|2018-05-05 12:05:37.066189|   MAIN > Installing error handling code
idl_130217         |INF|      1671|2018-05-05 12:05:37.066218|   MAIN > Reset optical loop gain to zero
idl_130217         |INF|      1672|2018-05-05 12:05:37.070018|   MAIN > Disable actuators coils with ADAM
idl_130217         |ERR|      1673|2018-05-05 12:05:37.070126| ADAM-MODBUS > [TcpReceiveException] Error receiving data (errno=0, error message means: Success, received Bytes = 0 ), socket closed. (code -15003) TcpConnection receive error File TcpConnection.cpp line 133
idl_130217         |INF|      1674|2018-05-05 12:05:37.188939|   MAIN > Coils disabled. Cleaning currents
AdSecArbitrator_131472|ERR|      1921|2018-05-05 12:05:37.514572|      IDL > Command returns error : IDL Accumulation was not ended after the max
20180505 12:05:37.5152 Alert: Warning: rest failed or syntax error occured
AdSecArbitrator_131472|INF|      1922|2018-05-05 12:05:38.277534| COMMANDHANDLER > Command execution failed: Fsm forced to Failure
AdSecArbitrator_131472|ERR|      1923|2018-05-05 12:05:38.277743|     MAIN > Rest: FATAL - IDL Accumulation was not ended after the max

-- %USERSIG{DougMiller - 2018-05-05}%
Topic revision: r3 - 05 May 2018, DougMiller
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback