Daytime LUT Confirmation with splines, SX 20180413

17:00 Closed loop, bin 1

17:15 Check actuators 230 and 263 with Guido. He will analyze and let us know what to do with those

18:09 Closed Loop
  • El 90
  • bin4, 400 Hz
  • gain 0.7, 0.1, 0.1
  • 181051, 181151 LUCI1 617, 618

18:31 Closed loop, bin 4, 400 Hz, 90 El
  • Ref values: -75.722, -51.105
  • LUT On, Bayside X On and moving
  • Change X Bayside * Bay X -75.5, TT volts -2.84, 1.93 TN 183120, 183242, 183307, 620, 621, 622
    • Bay X -75.6, TT volts -2.14, 1.59 TN 183416, 183439, 183530, 623, 624, 625
    • Bay X -75.7, TT volts -1.45, 1.28 TN 183647, 183735, 183802, 626, 627, 628
    • Bay X -75.8, TT volts -0.73, 0.95 TN 183840, 183908, 183933, 629, 630, 631
    • Bay X -75.9, TT volts -0.06 0.62 TN 184023, 184107, 184132, 632, 633, 634
    • Bay X -76.0, TT volts 0.64, 0.30 TN 184229, 184300, 184323, 635, 636, 637
    • Bay X -76.1, TT volts 1.31 -0.02 TN 184404, 184429, 184454, 638, 639, 640
    • Bay X -76.2, TT volts 2.02, -0.35 TN 184537, 184602, 184629, 641, 642, 643
    • Bay X -76.3, TT volts 2.71, -0.68 TN 184722, 184745, 184853, 644, 645, 646
  • Back to Ref Bayside position
    • TT volts -1.47, 1.29 TN 185156, 185220, 185244, 647, 648, 649 (encoder contribution is -0.06, 0.04, almost 0.0)
  • Change Y Bayside
    • Bay Y -50.8, TT volts -2.46, -1.06 TN 185534, 185610, 185642, 650, 651, 652
    • Bay Y -50.9, TT volts -2.11, -0.30 TN 185737, 185909, 185835, 653, 654, 655
    • Bay Y -51.0, TT volts -1.76, 0.45 TN 185913, 185936, 190012, 656, 657, 1
    • Bay Y -51.1, TT volts -1.41, 1.21 TN 190121, 190148, 190222, 2, 3, 4
    • Bay Y -51.2, TT volts -1.06, 1.97 TN 190303, 190334, 190357, 5, 6, 7
    • Bay Y -51.3, TT volts -0.71, 2.73 TN 190449, 190517, 190555, 8, 9, 10
  • Back to Ref Bayside position (Stages Off)
    • TT volts -1.22, 1.14 TN 190923, 191009, 191053, 11, 12, 13 (encoder contribution is -0.08, 0.06, almost 0.0)

19:14
  • Taking LUT data at zenith. -90 to 450 LUT off, Stages on, new Set Ref
  • First LUCI frame luci1.20180414.0014.fits
  • First Tracking Num: 20180413_191830
  • Last Tracking Num:20180413_195007
  • Last Luci Frame: luci1.20180414.0070.fits
19:54
  • 450 to -90
  • First LUCI Frame: luci1.20180414.0071.fits
  • First tracking Num: 20180413_195535
  • Last Trackin Num: 20180413_202734
  • Last Luci Frame: luci1.20180414.0127.fits
20:49
  • At 75 el
  • New Flat: 20180413_75el_36modes
  • Hexapod -1 0.47 4.95 283.27 -222.8
  • -90 -> 450 Stages on, everything else off
  • First Luci Image: luci1.20180414.0128.fits
  • First Track Num: 20180413_205327
  • Last Track Num:
  • There was some TT offset voltage, without the table being on. Clearing those out.
21:00
  • Closed loop in bin 1 to flatten the pupil out better
  • Flat:20180413_75el_400modes
  • Starting over at -90 -> 450
  • First Luci Frame: luci1.20180414.0134.fits
  • First Track num: 20180413_210612
  • Last Track num:20180413_213837
  • Last LUCI image: luci1.20180414.0190.fits
21:39
  • 450 -> -90
  • First Luci Image luci1.20180414.0191.fits
  • First Track Num: 20180413_214149
  • Last Track Num: 20180413_221443
  • Last Luci image: luci1.20180414.0247.fits
22:27
  • @ zenith -90 -> 450 Test
  • First LUCI frame: luci1.20180414.0248.fits
  • First Track Num: 20180413_222831
  • Last Track Num: 20180413_230139
  • Last Luci Frame: luci1.20180414.0304.fits

-- %USERSIG{DougMiller - 2018-04-13}%