Title

06:45 New Stage positions and foci for both LUCI1 and LUCI2 installed in aoroot
  • Change LUCIFER_* board setups
    • L = 53.6
    • R = 55,2 *Change fov.txt
    • L = -77.7, -50.8
    • R = -74.5, -50.4

07:00 Create new KL_v22 phase_matrix.sav and klmatrix_phase_inv.sav matrices
  • cp /local/aomeas/adsec_calib/if_functions/20180209_mirmodes/KLdata_fit_second_/KLmatrix_KL_v23.sav /local/aomeas/adsec_calib/M2C/KL_v22/phase_matrix.sav
% aoidl
IDL> restore, 'phase_matrix.sav', /v
IDL> klmatrix_inv = pseudo_invert(klmatrix, /DOUBLE)
IDL> save, FILE='klmatrix_phase_inv.sav', klmatrix_inv, dpix, idx_mask

07:15 First Preset.
  • RunAO fail because no slopes to AdSec
  • try cycling ccd39, slope computer processes. no go
  • power off, w_stop/start, power on. Success
  • lost time = 18 minutes

07:35 Closed loop. ESM
  • 12.2 mag star on ccd39
  • getting ~5 pixels on LUCI2 across the field. ~0.5" seeing. Dimm = 0.9-1.0
  • Note: Steve is running the AO system (power on and intervention mode)

08:32 Getting high currents around actuator 556 (or one nearby). In ESM mode with only 12 modes we are then getting a circle of push/pull

08:40 Loop open because we crossed the meridian at 88:36. Loop opened at 88:20. Rotator moving fast and could not offload TT to hexapod fast enough.
  • After meridian crossing Jochen resend the preset
  • Close the loop at about 88 elevation

-- %USERSIG{DougMiller - 2018-04-02}%