DX Reconstructors.

16:08
  • Waiting for the telescope.
18:29
  • Starting up the system.
  • I will start with the default flat and see where that leads.
19:11
  • Aligned on source, centering it. This is going to take a while, the pupils are terrible. I had to apply a LOT of coma to correct things, but still...
  • I will use the original pupil mask until things start to look better.
19:15
  • Starting with a 10 mode disturbance
  • Disturb, 4 frames/movement 4 push/pull, 48 cycles, optimized amano 6l.fits
  • 191736
  • Acquire, 4 iterations, open loop.
  • Fastlink is not working.
19:59
  • Fastlink now restored, re-centering the light on the pyramid.
  • Cube 202.846, -1.4
  • Intmat 200128
  • Recon 200306
20:04
  • Now in closed loop with last recon
  • Intmat 200513
  • Recon 200642
  • Closed loop to offload some aberrations
  • New Flat 20180216_Flat_10Mode_1
  • Forgot to turn on rerotator, the angle is very different, starting over.
20:10
  • Intmat, open loop.
  • 201203
  • Recon: 201327
  • Not enough light on the pupils, got impatient, autocentering and restarting.
  • Intmat 201846
  • Recon 202016
  • New Flat 20180216_Flat_10Mode_3
20:22
  • Now in closed loop
  • Intmat: 202301
  • Recon 202423
  • Flat: 20180216_Flat_10Mode_2 Not a typo
20: 27
  • Now 36 modes
  • Disturb with optimized_amano_per1.5, 4, 13
  • 202835
  • Intmat: 202943
  • Somebody turned the lights all on
  • Intmat: 203213
  • Recon: 203338
  • Shell rip while testing it, I pushed the buttons too quickly.
20:42
  • Second iteration: Still missing a couple of edges
  • Flat was horrible, I want to try some LBTI flats, with a new recon
  • Open loop 10
  • Intmat 204533
  • Recon: 204651
  • Now closed loop
  • Oops, this is a 36, oh well, we'll go with it.
  • Int 204808
  • 204942
  • 20180216_Flat_36Mode_1
20:51
  • Trying the 10 mode with a larger amplitude file
  • Disturb 210040
  • Intmat 210114
  • Recon 210236
21:05
  • Trying another file 672_0.7
  • 201534
  • Int 210604
  • So much coma that I can't get the whole mirror, trying the PSF gui to fill up more of the pupil,
21:21
  • The Adsec control gui died and I couldn't get it back.
  • It looks much flatter now.
  • Open loop
  • 212607
  • Recon: 212727
21:29
  • Int: 212850
  • Recon: 213030
2200:
  • Finally have the stupid pupil as full
  • Disturb 220242
  • Int 220404
  • 220529
  • Closed:
  • Int 220708
  • Recon: 220835
22:16
  • Better pupil filling.
  • Trying some more.
  • Open loop
  • Int 221733
  • recon 221858
  • 20180216_Flat_10Mode_4
  • Now I think we can rock and roll.
22:25
  • 36 Mode: 222618
  • Intmat: 222716
  • Recon: 222844
  • Finally, it's almost flat and the pupil is full.
  • 20180216_Flat_36Mode_2
22:30
  • 66 modes!
  • Sill using optimized_amano_6l
  • 223216
  • Int: 223305
  • Recon 223424
  • Pushed the dumb gain button too quickly... AGAIN! (Shell Rip)
  • Ripped again. I don't think it likes TT only gain of 0.65?
  • 20180216_Flat_66Mode_1
22:41
  • 153 Modes: 224526
  • Int 224638
  • Rec: 224822
  • Making new flat at 100 Hz and 12 lambda
  • 20180216_Flat_153Mode_1
22:56
  • 400 Modes
  • Disturb 225627
  • Int: 224822
  • 225907
  • Edge was rolling, I'll try again.
  • Int: 230634
  • 230803
  • Pupil was vignetted
  • Int: 231457
  • Recon: 231627
  • Let's try a different disturbance file: Optimized 2lambda
  • 232027
  • Int: 232124
  • 232252
  • No, adjusting pupil. Might need a new pupil mask (or an old one)
  • Int: 233055
23:38
  • Going to try a pupil file from TS3 20100525-171742
  • Amplitude file doug_400...0.6
  • Disturbance 234112
  • Intmat 234142
  • 234312
23:43
  • Now in closed loop
  • Intmat: 234442
  • Recon: 234625
23:48
  • 36 Modes
  • Amplitude file same as 10 mode recon (doug...0.6)
  • Disturb :234859
  • Intmat: 234625
  • Recon: 235135
23:54
  • 66 Modes
  • Disturb 235600
  • Intmat: 235640
  • Rec: 235810
0000
  • 153
  • Disturb 000248
  • Intmat 000337
  • Recon 000558
0018
  • 400
  • Disturb: 002118
  • Intmat: 002205
  • Recon: 002325
  • Unstable
  • Trying new disturb: ...2l.fits
  • 002706
  • Int 002921
  • 003055
  • Still unstable, will try fewer modes.
  • 250 003745
  • That's sort of stable, but the edge still wants to roll.
  • Trying 200 modes
  • 004444
  • Trying at 12 lambda and 100 hz
  • it's mostly stable
  • Taking new flat using 153 mode recon: 20180216_Flat_153Mode_2
  • Trying new intmat, disturb: optimized amano 6l
  • Disturb: 005312
  • Intmat: 005358
  • Recon: 005523
  • Forgot to turn the camera lens off
  • Intmat: 005842
  • 010015
  • That one took longer to fail
  • Trying 250 modes again
  • 010306
  • 20180216_Flat_250Mode_1
0106
  • Going to try 400 modes again.
  • Took a new flat at 100 Hz, 6V TT modulation
  • 20180216_Flat_250Mode_2
  • doug_400_2l.fits amplitude file
  • Disturb:011125
  • Intmat: 011230
  • Recon: 011356
  • Left the camera lens on
  • Intmat: 011657
  • Recon: 011837
  • Finnally! You Blankety Blank!
  • 20180216_Flat_400Mode_1
0124
  • Now another 400 mode
  • Intmat: 012643
  • Recon: 012811
0157
  • Tried to remove an actuator or two, but that made things worse.
  • Going to try 12 iterations, to see if that makes things more stable
  • Intmat: 022134
  • 022504
  • BAD!
0232
  • Had enough for tonight.
  • Hexapod 0.779 2.207 3.627 -317.759 156.204
  • Cube: -2.2, 202.818

-- %USERSIG{GregoryTaylor - 2018-02-16}%
Topic revision: r6 - 17 Feb 2018, GregoryTaylor
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.