DX Calculation of Influence Functions for TS3 20180212

18:40 Start over processing
  • Found that the problem was I had collected modes 0-649 but only had 643 actuators. Went into the directory
    • /local/aomeas/adsec_calib/if_functions/20180209_225942
    • and removed filed mode_643.sav -> mode_649.sav
  • Now need to recreate mm object

18:44 Processing

  • IDL> list_low_amp=['20180209_210838',.... (see TWiki from 20180209)
  • IDL> mm = obj_new('mirmodes', list_low_amp, data_dir = '/local/aomeas/adsec_calib/if_functions')
  • IDL> mm->summary_opds
tracknum        nn     amp [nm]     first      last     missing    sampling
20180209_210838     125      500.0     0     4     0     990 x 1002
20180209_211239     125      350.0     5     9     0     990 x 1002
20180209_211609     51      250.0     10     19     0     990 x 1002
20180209_215352     35      150.0     20     37     0     990 x 1002
20180209_215709     35      150.0     38     55     0     990 x 1002
20180209_220108     35      150.0     56     73     0     990 x 1002
20180209_220305     35      150.0     74     91     0     990 x 1002
20180209_220534     35      100.0     92     109     0     990 x 1002
20180209_220724     35      100.0     110     127     0     990 x 1002
20180209_220900     35       80.0     128     145     0     990 x 1002
20180209_221054     35       80.0     146     163     0     990 x 1002
20180209_221221     35       80.0     164     181     0     990 x 1002
20180209_221358     35       80.0     182     199     0     990 x 1002
20180209_221655     35       70.0     200     217     0     990 x 1002
20180209_221909     35       50.0     218     235     0     990 x 1002
20180209_222027     35       50.0     236     253     0     990 x 1002
20180209_222154     35       50.0     254     271     0     990 x 1002
20180209_222424     35       50.0     272     289     0     990 x 1002
20180209_222627     35       40.0     290     307     0     990 x 1002
20180209_222805     35       40.0     308     325     0     990 x 1002
20180209_222931     35       40.0     326     343     0     990 x 1002
20180209_223123     35       40.0     344     361     0     990 x 1002
20180209_223306     35       40.0     362     370     0     990 x 1002
20180209_223538     35       40.0     371     379     0     990 x 1002
20180209_223640     35       40.0     380     397     0     990 x 1002
20180209_223755     35       40.0     398     415     0     990 x 1002
20180209_223916     35       40.0     416     433     0     990 x 1002
20180209_224155     35       40.0     434     451     0     990 x 1002
20180209_224344     35       40.0     452     469     0     990 x 1002
20180209_224515     35       40.0     470     487     0     990 x 1002
20180209_224716     35       40.0     488     505     0     990 x 1002
20180209_224844     35       40.0     506     523     0     990 x 1002
20180209_225045     35       40.0     524     541     0     990 x 1002
20180209_225236     35       40.0     542     559     0     990 x 1002
20180209_225411     35       40.0     560     577     0     990 x 1002
20180209_225522     35       40.0     578     595     0     990 x 1002
20180209_225654     35       40.0     596     613     0     990 x 1002
20180209_225811     35       40.0     614     631     0     990 x 1002
20180209_225942     35       40.0     632     642     0     990 x 1002

  • IDL> mm->collect_opds
  • IDL> mm->mask_calibration, SHOW
    • Image: Union of Mask
      union_mask.jpg
    • Image: Valid Points in Mask
      valid_points.jpg
  • IDL> mm->produce_ifmat
  • IDL> mm->check_noise
    • Image: Surface noise in nm
      surface_nm.jpg
    • Image: Surface noise rms in nm
      surface_nm_rms.jpg
  • IDL> mm->inv_ifmat
  • IDL> mm->interactive_tweak_mask
    • Image: Inner Mask
      inner_mask.jpg
    • Image: Outer Mask
      outer_mask.jpg
    • saved as "best"
  • IDL> mm->tweak_ifmat, "best"
  • IDL> mm->showme_the_modes
    • Image: Mode Plots
      surface_plots.jpg
  • IDL> mm->inv_ifmat, mask_id="best"
    • Image: Single Values
      single_values.jpg
    • Image: Last Eigenmode
      last_eigenmode.jpg
  • IDL> klf = obj_new('klfit', mm, mask_ID
  • IDL> klf->create_theo_kls
  • IDL> klf->create_ortho_fitted_kls
    • Code error in /home/aoeng/aoroot/idl/adsec_lib/calibration/optical/klfit__define.pro
      • from hdr = [hdr, ['SAVEDIR', mm_obj->save_dir()]]
      • to hdr = [hdr, ['SAVEDIR', self._mm_obj->save_dir()]]
      • Must add to svn (Xianyu)
  • IDL> klf->check_fitting
    • Image: Peak Force
      peak_force.jpg
    • Image: Fitting Error
      fitting_error.jpg
  • IDL> klf->showme_the_modes, 'ORTHOFIT', nrows=20, ncol=20, zoom=0.11
    • Image: KL Mode Fitting
      kl_mode_fits.jpg
  • IDL> print, klf->kl_theo_dir()
    • /local/aomeas/adsec_calib/if_functions/20180209_mirmodes/KLdata_theo_best/
  • IDL> print, klf->kl_fit_dir()
    • /local/aomeas/adsec_calib/if_functions/20180209_mirmodes/KLdata_fit_best_/

-- %USERSIG{DougMiller - 2018-02-12}%

I Attachment Action Size Date Who Comment
fitting_error.jpgjpg fitting_error.jpg manage 83 K 12 Feb 2018 - 23:05 DougMiller Image:
inner_mask.jpgjpg inner_mask.jpg manage 87 K 12 Feb 2018 - 20:16 DougMiller Image:
kl_mode_fits.jpgjpg kl_mode_fits.jpg manage 610 K 12 Feb 2018 - 23:05 DougMiller Image:
last_eigenmode.jpgjpg last_eigenmode.jpg manage 29 K 12 Feb 2018 - 20:16 DougMiller Image:
outer_mask.jpgjpg outer_mask.jpg manage 83 K 12 Feb 2018 - 20:16 DougMiller Image:
peak_force.jpgjpg peak_force.jpg manage 78 K 12 Feb 2018 - 23:05 DougMiller Image:
single_values.jpgjpg single_values.jpg manage 35 K 12 Feb 2018 - 20:16 DougMiller Image:
surface_nm.jpgjpg surface_nm.jpg manage 75 K 12 Feb 2018 - 19:29 DougMiller Low Amplitude Set
surface_nm_rms.jpgjpg surface_nm_rms.jpg manage 90 K 12 Feb 2018 - 19:29 DougMiller Low Amplitude Set
surface_plots.jpgjpg surface_plots.jpg manage 551 K 12 Feb 2018 - 20:16 DougMiller Image:
union_mask.jpgjpg union_mask.jpg manage 39 K 12 Feb 2018 - 19:29 DougMiller Low Amplitude Set
valid_points.jpgjpg valid_points.jpg manage 130 K 12 Feb 2018 - 19:29 DougMiller Low Amplitude Set
Topic revision: r3 - 13 Feb 2018, DougMiller
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.