SX AO TT LUT with RR, off Zenith

19:22 Loop closed at Zenith. Troubles before

19:23 Bin 2, 600 HZ, 11.3 mag
  • lamp at 34%
  • ~12000 counts peak on LUCI
  • Round image
  • clear/HKspec
  • ~120 count in corner spots
  • at rotator 341, source at 906, 1133
  • All lights on except overhead floods
  • 2.5 sec
  • hex -1.25, 1.02, 2.35, 143, -215
  • Bayside -75.74, -50.33, 48.6

20:33 Tip over to 75 El
  • Bin 4, 600 Hz
  • Lamp at 35%
  • move 1 degree at a time. Let offload
  • At 75 hex -0.5075, 0,466, 2.36, 200, -144

20:38 Flat at 75 El
  • Bin 1, 600 Hz
  • 20180125_75_El.sav

20:42 Close loop with Bin 2, 600 Hz
  • Not stable. put HO1 to 0.5 and get pattern and skip frame
  • Happened a second time. Pupil was aligned

20:48 Close loop with Bin 4, 600 Hz, 11.3 mag
  • Rot 355
  • source at 886, 1119
  • ~ 10000 counts peak
  • ~ 350 counts in corner spots

21:02 At Rotator 450
  • Gains 0.6, 0.15, 0.1

21:02 Start at 450. Bayside stages powered on
  • 450, 111, 112, 113, 210405, 210431, 210453
  • 420, 114, 115, 116, 210559, 210622, 210644
  • 390, 117, 118, 119, 210751, 210813, 210837
  • 360, 120, 121 122, 210943, 211006, 211028
  • 330, 123, 124, 125, 211135, 211157, 211220
  • 300, 126, 127, 128, 211326, 211348, 211410
  • 270, 129, 130, 131, 211517, 211539, 211601
  • 240, 132, 133, 134, 211708, 211730, 211752
  • 210, 135, 136, 137, 211858, 211923, 211945
  • 180, 138, 139, 140, 212051, 212114, 212137
  • 150, 141, 142, 143, 212242, 212304, 212327
  • 120, 144, 145, 146, 212432, 212454, 212517
  • 90, 147, 148 149, 21 Loop not stable in TT. Stop script

21:31
  • 213513 Tn with gains 0.3, 0.05, 0.05

21:55 Turned on OVMS telemetry saving

  • 220933 bin4, 600Hz
  • 221243 Bin 1, 990 Hz
  • 222144 Bin 1, 600 Hz
  • 222310 Bin 1, 600 Hz
  • 222613 Bin 4, 600 Hz
  • 222653 Bin 4, 600 Hz (gains all 0.0)
  • 223100 Bin 1, 990 Hz
  • 223131 Bin 1, 990 Hz (gains all 0.0)

22:40 Darks
  • 52, 53 2.5 sec

22:40 Saved board setup at FLAO_RR_75el_25jan18

-- %USERSIG{DougMiller - 2018-01-25}%
Topic revision: r2 - 25 Jan 2018, DougMiller
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback