SX TT LUT measurements (TT and Stage calibrations)

16:00 Setting up telescope and system
  • Powered on WUnit
  • No currents arriving at Mirror GUI
    • Power off, IDL and Fastdiagn processes off/on, AdSecarb process off/on, Power on, Load and set
  • Close 990 Hz loop=> no slopes to Adsec
    • Is this because I cycled AdSec after powering on WUnit???

16:24 Power cycle WUnit
  • close 990 Hz loop and slopes arrive

17:23 Closed loop with LUCI images
  • bin 4, 400 Hz
  • Clear/HKSpec 2.5 s
  • Instrument Rotator 341 degrees

17:23 Start bayside data collection
  • Y stage -50.3
  • Change X stage
  • -75.9 177, 178, 179
  • -75.6 180, 181, 182
  • -75.3 183, 184, 185

17:34 Start again. Arcetri needs TN with LUCI image
  • -75.0 190, 191, 192, 173518, 173544, 173616
  • -75.5 193, 194, 195, 173755, 173850, 173921
  • -76.0 196, 197, 198, 174131, 174155, 174239
  • -76.5, 199, 200, 201, 174409, 174433, 174455
  • -77.0, 202, 203, 204, 174610, 174634, 174708
  • -77.5, 205, 206, 207, 174810, 174830, 174853
  • -78.0, 208, 209, 210, 174958, 175031, 175053

17:52 Y stage changing, X stage -78.0
  • -50.3, 208, 209, 210, 174958, 175031, 175053
  • -50.8, 211, 212, 213, 175328, 175401, 175425
  • -51.3, 214, 215, 216, 175524, 175557, 175626 extra tn?
  • -51.8, 218, 219, 220, 175736, 175830, 175853
  • -52.3, 221, 222, 223, 180109, 180136, 180158
  • -52.8, 224, 225, 226, 180313, 180337, 180357
  • -53.3, 227, 228, 229, 180507, 180543, 180606

18:06 Start TT calibration
  • Y = 0
  • X changing
  • -3.0, 230, 231, 232, 180918, 180951, 181021
  • -2.0, 233, 181115, Loop opened
  • Start over
  • -3.0, 234, 235, 236, 181318, 181345, 181409
  • -2.0, 237, 238, 239, 181457, 181523, 181547
  • -1.0, 240, 241, 242, 181630, 181658, 181724
  • 0.0, 243, 244, 245, 181834, 181857, 181923
  • 1.0, 256, 247, 248, 182043, 182110, 182132
  • 2.0, 249, 250, 251, 182226, 182306, 182338
  • 3.0, 252, 253, 254, 182437, 182459, 182525

18:26 X = 0.0
  • -3.0, 255, 256, 257, 182744, 182809, 182903
  • -2.0, 258, 259, 260, 183003, 183027, 183048
  • -1.0, 261, 262, 263, 183142, 183203, 183229
  • 0.0, 264, 265, 266, 183326, 183350, 183418
  • 1.0, 267, 268, 269, 183532, 183555, 183619
  • 2.0, 270, 271, 272, 183701, 183723, 183751
  • 3.0, 273, 274, 275, 183842, 183912, 183935

18:40 Switch to 990 Hz to see if volt-pos changes, bin2, 990 Hz
  • X = 0
  • 3.0, 276, 277, 278, 184714, 184738, 184808
  • 0.0, 279, 280, 281, 184946, 185012, 185034
  • -3.0, 282, 283, 284, 185202, 185227, 185313

18:54 Y = 0.0
  • -3.0, 285, 286, 287, 185636, 185704, 185732
  • 0.0, 01, 02, 03, 04, 190009, loop opened, close, 190217, 190312, 190337
  • 3.0, 05, 06, 07, 190513, 190543, 190610

19:06 Done

19:14 LUCI1 dark, blind/blind, 2.5 s 08

-- %USERSIG{DougMiller - 2018-01-20}%