Actuator Lists:

# Guido confirmed on 20170503 that there are no missing magnets on TS5
476 : 1 : 0 : 0 : 20151002 : GB : after TSS refurbishment based on Roberto's measurements actuators does not apply current
539 : 1 : 0 : 0 : 20151002 : GB : after TSS refurbishment based on Roberto's measurements actuators does not apply current
# 2 : 1 : 0 : 0 : 20170509 : DLM : Actuators not in Influence Functions
# 32 : 1 : 0 : 0 : 20170509 : DLM : Actuators not in Influence Functions
# 165 : 1 : 0 : 0 : 20170509 : DLM : Actuators not in Influence Functions
# 373 : 1 : 0 : 0 : 20170509 : DLM : Actuators not in Influence Functions
# 451 : 1 : 0 : 0 : 20170509 : DLM : Actuators not in Influence Functions
# 511 : 1 : 0 : 0 : 20170509 : DLM : Actuators not in Influence Functions
# 578 : 1 : 0 : 0 : 20170509 : DLM : Actuators not in Influence Functions
#
# No Position
#
552 : 0 : 1 : 0 : 20170503 : DLM : Tried to put it back in but get IDL An in-use...bla error on load program 552,00260318um
14 : 0 : 1 : 0 : 20150521 : GB : In no_pos list in old flat (20150513 flat). However, was able to add the other 4 in the cross back in
#
# Actuators not used when Influence functions were measured (from m2c.fits)
#
2 : 0 : 1 : 0 : 20170509 : DLM : Actuators not in Influence Functions
32 : 0 : 1 : 0 : 20170509 : DLM : Actuators not in Influence Functions
165 : 0 : 1 : 0 : 20170509 : DLM : Actuators not in Influence Functions
373 : 0 : 1 : 0 : 20170509 : DLM : Actuators not in Influence Functions
451 : 0 : 1 : 0 : 20170509 : DLM : Actuators not in Influence Functions
511 : 0 : 1 : 0 : 20170509 : DLM : Actuators not in Influence Functions
578 : 0 : 1 : 0 : 20170509 : DLM : Actuators not in Influence Functions
#
# Actuators not used when Reconstructor Matrix was measured (from Rec_20160229_184300.fits, 20160229_172130_stability_default.sav
#
1 : 0 : 1 : 0 : 20170509 : DLM : Actuators not in Reconstructor Matrix
6 : 0 : 1 : 0 : 20170509 : DLM : Actuators not in Reconstructor Matrix
37 : 0 : 1 : 0 : 20170509 : DLM : Actuators not in Reconstructor Matrix
216 : 0 : 1 : 0 : 20170509 : DLM : Actuators not in Reconstructor Matrix
243 : 0 : 1 : 0 : 20170509 : DLM : Actuators not in Reconstructor Matrix
262 : 0 : 1 : 0 : 20170509 : DLM : Actuators not in Reconstructor Matrix
297 : 0 : 1 : 0 : 20170509 : DLM : Actuators not in Reconstructor Matrix
340 : 0 : 1 : 0 : 20170509 : DLM : Actuators not in Reconstructor Matrix
385 : 0 : 1 : 0 : 20170509 : DLM : Actuators not in Reconstructor Matrix
393 : 0 : 1 : 0 : 20170509 : DLM : Actuators not in Reconstructor Matrix
409 : 0 : 1 : 0 : 20170509 : DLM : Actuators not in Reconstructor Matrix
483 : 0 : 1 : 0 : 20170509 : DLM : Actuators not in Reconstructor Matrix
484 : 0 : 1 : 0 : 20170509 : DLM : Actuators not in Reconstructor Matrix
501 : 0 : 1 : 0 : 20170509 : DLM : Actuators not in Reconstructor Matrix
530 : 0 : 1 : 0 : 20170509 : DLM : Actuators not in Reconstructor Matrix
541 : 0 : 1 : 0 : 20170509 : DLM : Actuators not in Reconstructor Matrix
546 : 0 : 1 : 0 : 20170509 : DLM : Actuators not in Reconstructor Matrix
654 : 0 : 1 : 0 : 20170509 : DLM : Actuators not in Reconstructor Matrix
#
# No ICC
#
149 : 0 : 0 : 1 : 20170504 : DLM : High forces in flat 0.2N and in CL 0.27N
332 : 0 : 0 : 1 : 20170504 : DLM : Jump in CL to high forces of -0.29N

19:54
  • Acquired intmat, 4 iterations, in closed loop, with recon 20160229_184300, gain0.05, initial disturbance 600...3l
  • 20170511_195826
  • Recon: 200032
  • It WORKS!
  • Autogains 0.72 0.32 0.20
  • Dataset w/0 disturbance 200602
  • Disturbance: /local/aomeas/adsec_calib/CMD/disturb/dist_flao2_KL_v20_atm_s0.8_L040.0_v15.0_ovfreq1000.00_sd3892.fits
  • Autogains: 0.67 0.49 0.39
  • Dataset: 201113, 201259, 201356, 201414, 201455
  • New Disturbance, 201455
  • Amplitude file 600_optimized_6l.fits
  • intmat: 202226
  • Recon:202357
  • intmat204049
  • Intmat: 204351
  • 204524
  • Intmat 210032
  • 210229
12:08
  • 10 mode disturbance: 210756
  • Intmat: 210916
  • Recon: 211102
  • This one works, Now 36 modes
  • Disturb: 211348
  • Intmat: 211523
  • Recon: 211708
  • OK, now 66 modes
  • Disturb: 211944
  • Intmat: 212139
  • Recon: 212328
  • Now 153 modes
  • Disturb: 212815
  • Intmat: 212328
  • Recon: 213131
  • Now 400 modes
  • Disturb: 213503
  • Intmat: 213634
  • Recon: 213812
  • 400 modes with the last recon.
  • same disturb
  • Intmat: 214227
  • Disturb: 214404
  • New Flat: rec_act_20170511_5.sav
  • 48 iterations
  • Intmat: 215407
  • reconstructor: 220822
  • Reconstructor, 300 mode: 221100
22:15
  • Test with disturb: /local/aomeas/adsec_calib/CMD/disturb/dist_flao2_KL_v20_atm_s0.8_L040.0_v15.0_ovfreq1000.00_sd3892.fits
  • Optimize gain: 0.67 0.49 0.41
  • Dataset: 221656, 221801, 221837, 221933, 222008
  • Gain: 0.67 0.39 0.31
  • Dataset: 222328, 222346, 222405, 222428, 222455

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170511_222328 ??? 7.9 324000 4 NaN -1.00 220822 1 400 600 0.7 0.4 0.3 3 705 ON -1.0 ? -1 -1 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170511_222346 ??? 7.9 324000 3 NaN -1.00 220822 1 400 600 0.7 0.4 0.3 3 704 ON -1.0 ? -1 -1 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170511_222405 ??? 7.9 324000 3 NaN -1.00 220822 1 400 600 0.7 0.4 0.3 3 704 ON -1.0 ? -1 -1 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170511_222428 ??? 7.9 324000 3 NaN -1.00 220822 1 400 600 0.7 0.4 0.3 3 705 ON -1.0 ? -1 -1 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170511_222455 ??? 7.9 324000 3 NaN -1.00 220822 1 400 600 0.7 0.4 0.3 3 705 ON -1.0 ? -1 -1 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error

  • New 400 Mode Recon:
    20170511_222328_jitter.jpg

  • Was at 600 Hz still
  • 990 Hz
  • Autogain: 0.38 0.39 0.38
  • Dataset: 222709, 222725, 222737, 222749, 222804
  • Datasets w/ 300:
  • gain 0.47 0.39 0.38
  • 230234, 230329, 230351, 230405, 230422

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170511_230234 ??? 7.9 324000 4 NaN -1.00 221100 1 300 990 0.5 0.4 0.4 3 431 ON -1.0 ? -1 -1 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170511_230329 ??? 7.9 324000 5 NaN -1.00 221100 1 300 990 0.5 0.4 0.4 3 431 ON -1.0 ? -1 -1 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170511_230351 ??? 7.9 324000 4 NaN -1.00 221100 1 300 990 0.5 0.4 0.4 3 431 ON -1.0 ? -1 -1 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170511_230405 ??? 7.8 324000 3 NaN -1.00 221100 1 300 990 0.5 0.4 0.4 3 433 ON -1.0 ? -1 -1 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170511_230422 ??? 7.8 324000 3 NaN -1.00 221100 1 300 990 0.5 0.4 0.4 3 434 ON -1.0 ? -1 -1 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error

  • New 300 Mode Recon:
    20170511_230234_jitter.jpg

23:36
  • Investigating vibrations, 232625
-- %USERSIG{GregoryTaylor - 2017-05-11}%
I Attachment Action Size Date Who Comment
20170511_222328_jitter.jpgjpg 20170511_222328_jitter.jpg manage 115 K 12 May 2017 - 08:37 DougMiller New 400 Mode Recon
20170511_230234_jitter.jpgjpg 20170511_230234_jitter.jpg manage 113 K 12 May 2017 - 08:38 DougMiller New 300 Mode Recon
Topic revision: r2 - 12 May 2017, DougMiller
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback