INAF Science with DX AO

05:05 Arrive and power on
  • Test Fastlink: OK

05:17 AO System Ready to go

05:24 Switch from MODS to LUCI2

05:32 Steve send preset to point and collimate

05:48 No Gopt
  • Opt Loop Data 054828
  • aoidl

05:54 Loop Closed
  • NCPA on

06:02 Loop Open
  • 1.97, 0.62, 0.41 (1.67 set TT)
  • 0.37, 0.14, 0.09 (0.24 Gopt)

06:15 Loop Closed again.
  • Had to use Re-Close loop button and then set correct gain (with Gopt)

06:22 Loop Open
  • looked like a large Tip and edge of mirror at 11:00 rolled
  • re-close loop and set gain
  • < 30 seconds

07:34 TN, bin 2x2 990 Hz, 10.0 mag
  • 073417
  • 073445
  • 073809

07:56 Preset to PSF start
  • presetAO failed because mag 30 sent

08:00 Preset OK, 9.9 mag star
  • 1.53, 0.42, 0.41
  • 0.37, 0.10, 0.10

08:07 Loop Closed, NCPA On

08:18 PresetAO Failed
  • bayside Y timeout
  • turned off and on and seemed to move OK

08:20 PresetAO again 13.0 mag
  • 1.94, 0.95, 0.63
  • 1.6, 0.9, 0.6
  • 0.43, 0.24, 0.17 (Gopt = 0.24)
  • Camera lens centering turned off
  • bin 3, 400 Hz, 13.3 mag

08:32 TN
  • 083238
  • 083403

08:42 Loop Open. Optical gain may have diverged and gains got too high

08:44 Actuator 514 get high currents. Cause volcano around it
  • Start new Mirror GUI and current not available
  • Mirror GUI current not available and actuator 514 volcano:
    Mirror_GUI_No_Current.jpg

08:50 Loop Open: Optical Gain diverges
  • changing from 0.24 to 0.01 and back on each iteration
  • Closed loop but did not turn on Optical gain nor NCPA
  • Images on LUCI look the same (faint galaxies)
  • Seeing is now 0.6. Was 0.9

10:00 Done
  • Power off WUnit

-- %USERSIG{DougMiller - 2017-11-25}%
I Attachment Action Size Date Who Comment
Mirror_GUI_No_Current.jpgjpg Mirror_GUI_No_Current.jpg manage 144 K 25 Nov 2017 - 09:12 DougMiller Mirror GUI current not available and actuator 513 volcano
Topic revision: r4 - 25 Nov 2017, DougMiller
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback