16:07
  • Waiting for LUCI
16:17
  • Beginning to test new LUT
Angle LUT on Comment
300 80, 81 Light set to 80, reads 81 Can't save tracking numbers yet.
120 82, 83 No Comment
17:20
  • Starting at -90 and going every 30 degrees
  • Motors in closed loop.

Angle Tracking # Luci Frames
-90 20171113_172814, 172837 91, 92
-60 173046, 173118 93, 94
-30 173313, 173336 95, 96
0 173558, 173627 97, 98
30 173837, 173858 99, 100
60 174129, 174155 101, 102
90 174628, 174648 104, 105 (not a typo)
120 174844, 174902 106, 107
150 175101, 175118 108, 109
180 175304, 175340 110, 111
210 175613, 175649 112, 113
240 175841, 175912 114, 115
270 180109, 180131 116, 117
300 180343, 180401 118, 119
330 180531, 180555 120, 121
360 180717, 180755 122, 123
390 180932, 180951 124, 125
420 181131, 181153 126, 127
450 181637, 181702 129, 130
18:19
  • Blind/Blind
  • 181929, 182023, 131, 132
  • Official Dark with Blind Blind
  • 20171113_182418, 133
  • 10 frames
  • 1 Frame 20171113_182549, 134
18:28
  • Now, the same thing but with the stage brakes set.
Angle Tracking # Luci Frame
-90 183904, 184112 135, 136
-60 184451, 184508 137, 138
-30 184654, 184714 139, 140
0 184843, 184900 141, 142
30 185047, 185108 143, 144
60 185257, 185318 145, 146
90 185454, 185513 147, 148
120 185658, 185720 149, 150
150 185927, 190001 151, 0001
180 190129, 190150 2, 3
210 190342, 190400 4, 5
240 190558, 190617 6, 7
270 190734, 190752 8, 9
300 190933, 190952 10, 11
330 191221, 191239 12, 13
360 191406, 191425 14, 15
390 191604, 191624 16, 17
420 191815, 191847 18, 19
450 192030, 192053 20, 21
19:30
  • Taking tracking numbers with the control on the baysides active.
  • Tracking numbers at 0, +1mm, +2mm, 0, -1, -2. in X then Y
  • Luci Rotator at 210

Movement of PSF with bayside stages. Initial X = - 72.272, Y = - 49.539
Offset Tracking # Luci Frame
X + 0 193553, 193611 22, 23
X - 1 193740, 193802 24, 25
X - 2 193918, 193937 26, 27
X + 0 194145, 194205 28, 29
X + 1 194312, 194358 30, 31
X + 2 194537, 194558 32, 33
X + 0 194737, 194759 34, 35
Y + 0 194857, 194915 36, 37
Y + 1 195004,195023 38, 39
Y + 2 195128, 195150 40, 41
Y + 0 195331, 195356 42, 43
Y - 1 195502, 195527 44, 45
Y - 2 195643, 195739 46, 47
Y + 0 195928, 195954 48, 49