DX 4D Flattening and Influence Function Measurements

05:15 Getting system aligned

05:58
  • Bump at 4:30, act 479 has high force, -0.42 N (maybe will remove from use in pos)
  • AdOpt>print, fsm_load_shape('/local/aomeas/adsec_calib/flat/20170830_113309/flattening_result.sav', force_max_mode=100)
  • AdOpt>print, opt_int_mat_reduce2(200, track='20170830_103907')

06:21
  • Tnlist = ['20170830_123006','20170830_123241','20170830_123616','20170830_124125']

06:53 Burst data for noise calculation
  • HBS Off
  • Summer Chiller (refrigerator Off)
  • Water pumps off
  • >>> comm4d.capture(1000, folder='20170831_065300_noise')

06:59 Burst data for noise calculation
  • HBS Off
  • Summer Chiller (refrigerator Off)
  • Water pumps ON
  • >>> comm4d.capture(1000, folder='20170831_065900_noise')

07:02 Analyze Burst data
  • >>> comm4d.produce('20170831_065300_noise')
  • >>> comm4d.produce('20170831_065900_noise')

07:00 Analyze IF data from last night
  • IDL> Tnlist = ['20170830_123006','20170830_123241','20170830_123616','20170830_124125']
  • IDL> print, if_redux(/modal, tnlist[0]) 1,2,3
  • IDL> print, build_int_mat(tnlist)

07:30
  • AdOpt>print, build_int_mat( ['20170830_103907', '20170830_111240','20170830_114343'])

07:20
  • IDL> tnho=['20170830_123431','20170830_123744']
  • IDL> print, if_redux(/modal, tnhyo[0]) 1

08:01 Compare vibration amplitude of today to 2013 measurement
  • ssh flao@adsecdx
  • $ cd /local/towerdata/meas/adsec_calib/if_functions/20130826_124249
  • $aoidl
  • IDL> restore, /verb, 'mode_650.sav'
  • IDL> image_show, opd, /sh

-- %USERSIG{DougMiller - 2017-08-31}%
Topic revision: r3 - 31 Aug 2017, DougMiller
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.