SX LUCI/AO Commissioning

01:45 ACE Preset

02:01 Complete
  • Optimize Gain = 1.27, 1.20, 0.78 (too high)
  • set to 1.2, 1.0 0.6

02:02 DX AdSec Arb died on first offset

02:13 Power On request

02:18 Finally got a response

02:18 Greg Killed all AdSec processes, not knowing that the power on was proceeding

02:24 ACE Preset
  • opt gain 1.27, 1.0, 0.78

02:31 On offset looked like the AO system didn't Pause before the telescope moved

03:10 Bin 1, 400 Mode, 4.6 mag, 1.14" seeing
  • 031031, 031130, 031304, 031558
  • Large offset (delta X = -32"), offset pupils (0.13 0.47) safe skip to open
    • 033224 (DX 033226)
    • IT 6333

04:09 Offset failed, unknown reason

x -66.82 y -50.53

04:20 Large offset (dX=16, dY-16) pupil offset (x=0.24, y=0.07) OK
  • 042054

05:27 Script Complete

05:30 Authorize as LUCI2 only. Greg is running the DX AO System

06:52 Fixed the ESM table on SX. $ADOPT_ROOT/calib/wfs/current/ao/table_LUCIFER_TTM-AO.txt
  • had bin 1 12 mode recons listed for bin 4

08:59 Rest SX Shell
  • At first, not jumping actuators
  • Collect 10000 frames: caught start of jumping actuators: 085929
  • first 2 actuators jumping
  • tried to SetFlatAO: failed
  • AdSec Arbitrator process dies
  • Looks like more actuators jumping with Arbitrator dead
  • Power off, Power On, Load Programs, no jumps, SetFlatAO: OK

09:40-57
  • Rested shell
  • Collected many sys_status from IDL Console and saved to /tmp/stat_*.sav
  • read into aoidl and used display routine
    • durning 1, no jumps on Mirror GUI
    • 1-5 jumps on Mirror GUI
  • stat_(1-4).sav, no jumps displayed
  • stat_5.sav, jump displayed
  • stat_6.sav, no jump, after power off/on

10:06 Rested
  • 100724 with act 350
  • stat_(6-7).sav taken while displayed showed 350 and and one other at 0.2m, but not shown in display of stat
    • not sure if stat_6 is from above or here??

12:20 ESM test
  • Closed loop OK
  • 124018, 124148

-- %USERSIG{DougMiller - 2017-09-25}%
I Attachment Action Size Date Who Comment
bin_1_opt_gain_bump_1.5.movmov bin_1_opt_gain_bump_1.5.mov manage 84 MB 24 Sep 2017 - 03:59 DougMiller bin_1_gain_opt_bump_1.5
bin_1_opt_gain_bump_2.3.movmov bin_1_opt_gain_bump_2.3.mov manage 47 MB 24 Sep 2017 - 03:58 DougMiller bin_1_gain_opt_bump_2.3
Topic revision: r13 - 25 Sep 2017, DougMiller
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback