DX on Sky Checkout

02:15
  • Failed to center pupils.
  • Reset WFS arb and Pupil check ccd39 and started from the preset.

02:42
  • Had a few skip frames, but the preset continued as normal. It looked like the camera lens was going off target.
  • Datasets: No AO: 030444, 030526, 030556, 030626

03:49
  • Had to do a restart and there was a problem with active optics runaway.
  • Gains 1.70 0.89 0.38
  • Datasets Open loop (a little bit of tip-tilt): 041803, 041847, 041924, 042019

04:30
  • NCPA off
  • 043149, 043224, 043256, 043332

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170919_043149 ??? 9.1 237242 10 1.39 0.93 b1m400 1 400 990 0.4 0.2 0.1 3 140 ON 41.1 FeII clear 157 100 ONSKY zero.fits  
20170919_043224 ??? 9.1 236866 5 1.15 1.04 b1m400 1 400 990 0.4 0.2 0.1 3 138 ON 46.2 FeII clear 157 100 ONSKY zero.fits  
20170919_043256 ??? 9.1 236530 12 1.11 1.02 b1m400 1 400 990 0.4 0.2 0.1 3 138 ON 46.3 FeII clear 157 100 ONSKY zero.fits  
20170919_043332 ??? 9.1 236143 11 1.23 1.02 b1m400 1 400 990 0.4 0.2 0.1 3 140 ON 42.4 FeII clear 157 100 ONSKY zero.fits  

04:43
  • Disturb: CmdDisturb _20170407_191353
  • NCPA On
  • 043522, 043616, 043657, 043741

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170919_043522 ??? 9.2 234960 10 1.23 1.29 b1m400 1 400 990 0.4 0.2 0.1 3 132 ON 47.6 FeII clear 157 100 ONSKY zero.fits  
20170919_043616 ??? 9.1 234379 7 1.24 0.93 b1m400 1 400 990 0.4 0.2 0.1 3 140 ON 50.7 FeII clear 157 100 ONSKY zero.fits  
20170919_043657 ??? 9.1 233938 10 1.18 0.88 b1m400 1 400 990 0.4 0.2 0.1 3 141 ON 47.5 FeII clear 157 100 ONSKY zero.fits  
20170919_043741 ??? 9.1 233464 8 1.20 1.21 b1m400 1 400 990 0.4 0.2 0.1 3 134 ON 51.9 FeII clear 157 100 ONSKY zero.fits  

04:54
  • Bin 2 experiments.
  • NCPA off
  • 051136, 051220, 051605, 054156

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170919_051136 ??? -NaN 211186 11 0.97 0.85 b2m153 2 153 991 0.4 0.2 0.1 3 -1 ON 38.4 FeII clear 157 100 ONSKY NO  
20170919_051220 ??? -NaN 210767 10 0.92 0.79 b2m153 2 153 991 0.4 0.2 0.1 3 -1 ON 41.8 FeII clear 157 100 ONSKY NO  
20170919_051314 ??? -NaN 210172 5 0.96 0.73 b2m153 2 153 991 0.4 0.2 0.1 3 -1 ON 42.4 FeII clear 157 100 ONSKY NO  
20170919_051605 ??? -NaN 208271 10 0.99 0.76 b2m153 2 153 991 0.4 0.2 0.1 3 -1 ON 42.1 FeII clear 157 100 ONSKY NO  
20170919_054156 ??? 9.0 191129 8 0.91 0.62 b2m153 2 153 991 0.5 0.1 0.1 3 605 ON 43.7 FeII clear 157 100 ONSKY zero.fits  

05:44
  • NCPA On Delayed because the telescope was still guiding, then LUCI got stuck.
  • 054518, 054549, 054622, 054653

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170919_054518 ??? 9.0 188890 12 0.87 0.61 b2m153 2 153 991 0.5 0.2 0.1 3 597 ON 45.2 FeII clear 157 100 ONSKY zero.fits  
20170919_054549 ??? 9.0 188553 9 0.87 0.49 b2m153 2 153 991 0.5 0.2 0.1 3 608 ON 49.2 FeII clear 157 100 ONSKY zero.fits  
20170919_054622 ??? 9.0 188181 8 0.83 0.52 b2m153 2 153 991 0.5 0.2 0.1 3 607 ON 44.9 FeII clear 157 100 ONSKY zero.fits  
20170919_054653 ??? 9.0 187838 11 0.80 0.62 b2m153 2 153 991 0.5 0.2 0.1 3 603 ON 47.2 FeII clear 157 100 ONSKY zero.fits  

06:03
  • Bin 1 NCPA off again
  • 061314, 061441, 061531, 061614
  • NCPA on
  • 061718, 061737, 061807, 061837

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170919_061708 ??? 9.1 167792 4 0.93 0.58 b1m400 1 400 990 0.4 0.2 0.1 3 135 ON 57.3 FeII clear 157 100 ONSKY zero.fits  
20170919_061737 ??? 9.1 167466 7 0.89 0.60 b1m400 1 400 990 0.4 0.2 0.1 3 136 ON 0.0   157 99 ONSKY zero.fits  
20170919_061807 ??? 9.2 167140 4 0.90 0.98 b1m400 1 400 990 0.4 0.2 0.1 3 129 ON 48.3 FeII clear 157 100 ONSKY zero.fits  
20170919_061837 ??? 9.1 166803 10 0.97 0.62 b1m400 1 400 990 0.4 0.2 0.1 3 136 ON 53.0 FeII clear 157 100 ONSKY zero.fits  

06:18
  • NCPA off, GOPT off
  • 062349, 062503, 062548, 062628

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170919_062349 ??? 9.1 163378 9 0.85 0.55 b1m400 1 400 990 1.4 0.6 0.4 3 135 ON 56.5 FeII clear 157 100 ONSKY zero.fits  
20170919_062421 ??? 9.1 163027 9 0.92 0.61 b1m400 1 400 990 1.4 0.6 0.4 3 135 ON 53.3 FeII clear 157 100 ONSKY zero.fits  
20170919_062509 ??? 9.1 162498 11 0.92 0.54 b1m400 1 400 990 1.4 0.6 0.4 3 134 ON 51.7 FeII clear 157 100 ONSKY zero.fits  
20170919_062548 ??? 9.1 162063 5 0.90 0.47 b1m400 1 400 990 1.4 0.6 0.4 3 136 ON 52.8 FeII clear 157 100 ONSKY zero.fits  
20170919_062628 ??? 9.1 161623 12 0.86 0.55 b1m400 1 400 990 1.4 0.6 0.4 3 135 ON 47.4 FeII clear 157 100 ONSKY zero.fits  

06:29
  • GOPT off, sinus disturb on: 063844
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170919_063844 ??? 9.2 153555 9 0.99 0.66 b1m400 1 400 990 1.7 0.7 0.3 3 131 ON 38.3 FeII clear 157 100 ONSKY zero.fits  
20170919_064004 ??? 9.2 152684 13 1.11 0.98 b1m400 1 400 990 0.5 0.2 0.1 3 127 ON 39.8 FeII clear 157 100 ONSKY zero.fits  

  • GOPT On, Sinus on: 064156
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170919_064156 ??? 9.1 151461 14 1.04 0.75 b1m400 1 400 990 0.5 0.2 0.1 3 133 ON 46.3 FeII clear 157 100 ONSKY zero.fits  
20170919_064239 ??? 9.1 150995 8 0.91 0.66 b1m400 1 400 990 0.5 0.2 0.1 3 133 ON 36.9 FeII clear 157 100 ONSKY zero.fits  

  • NCPA on: 064312, 064612
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170919_064312 ??? 9.1 150623 13 0.89 0.69 b1m400 1 400 990 0.4 0.2 0.1 3 133 ON 40.6 FeII clear 157 100 ONSKY zero.fits  
20170919_064612 ??? 9.2 148662 8 0.97 0.88 b1m400 1 400 990 0.4 0.2 0.1 3 130 ON 40.0 FeII clear 157 100 ONSKY zero.fits  

06:46
  • 300 Modes
  • GOPT off: 064846
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170919_064846 ??? 9.2 146987 9 0.90 0.73 b1m300 1 300 990 1.7 0.7 0.3 3 129 ON 47.2 FeII clear 157 100 ONSKY zero.fits  
20170919_064950 ??? 9.2 146289 12 0.94 0.85 b1m300 1 300 990 0.4 0.2 0.1 3 131 ON 45.8 FeII clear 157 100 ONSKY zero.fits  

  • GOPT On: 065020
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170919_065020 ??? 9.2 145962 14 1.02 0.75 b1m300 1 300 990 0.4 0.2 0.1 3 132 ON 42.4 FeII clear 157 100 ONSKY zero.fits  

  • NCPA: 065100
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170919_065100 ??? 9.2 145532 13 1.10 0.76 b1m300 1 300 990 0.4 0.2 0.1 3 132 ON 48.0 FeII clear 157 100 ONSKY zero.fits  

07:24
  • Bin 2 Mag 10.4
  • NCPA On
  • 072957, 073059, 073200, 073254
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170919_072957 ??? 10.7 264535 12 1.02 1.00 b2m153 2 153 991 0.6 0.2 0.1 3 125 ON 33.1 FeII clear 157 100 ONSKY zero.fits  
20170919_073059 ??? 10.7 264957 13 1.05 1.02 b2m153 2 153 991 0.6 0.2 0.1 3 127 ON 35.9 FeII clear 157 100 ONSKY zero.fits  
20170919_073200 ??? 10.7 265361 11 1.07 1.02 b2m153 2 153 991 0.6 0.2 0.1 3 120 ON 33.4 FeII clear 157 100 ONSKY zero.fits  
20170919_073254 ??? 10.7 265716 12 1.12 1.14 b2m153 2 153 991 0.6 0.2 0.1 3 122 ON 35.8 FeII clear 157 100 ONSKY zero.fits  
20170919_074535 ??? 10.7 270211 12 1.30 0.91 b2m153 2 153 991 2.2 0.7 0.2 3 116 ON 38.7 FeII clear 157 100 ONSKY zero.fits  
20170919_074618 ??? 10.7 270434 13 1.26 0.82 b2m153 2 153 991 2.2 0.7 0.2 3 117 ON 38.3 FeII clear 157 100 ONSKY zero.fits  

  • GOPT off: 074426, 074456, 074535, 074618
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170919_074535 ??? 10.7 270211 12 1.30 0.91 b2m153 2 153 991 2.2 0.7 0.2 3 116 ON 38.7 FeII clear 157 100 ONSKY zero.fits  
20170919_074618 ??? 10.7 270434 13 1.26 0.82 b2m153 2 153 991 2.2 0.7 0.2 3 117 ON 38.3 FeII clear 157 100 ONSKY zero.fits  

08:02
  • New GOPT process: No NCPA
  • 080315, 080347, 080435, 080521
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
% SR_ESPOSITO: Could not test SR quality
20170919_080315 ??? 10.7 274526 13 1.03 0.75 b2m153 2 153 991 0.4 0.2 0.1 3 119 ON 81.4 FeII clear 157 100 ONSKY zero.fits  
20170919_080347 ??? 10.7 274615 15 1.01 0.77 b2m153 2 153 991 0.4 0.4 0.2 3 118 ON 86.8 FeII clear 157 100 ONSKY zero.fits  
20170919_080435 ??? 10.7 274746 14 0.99 0.78 b2m153 2 153 991 0.4 0.4 0.2 3 118 ON 77.2 FeII clear 157 100 ONSKY zero.fits  
20170919_080521 ??? 10.7 274862 11 0.97 0.74 b2m153 2 153 991 0.4 0.4 0.2 3 122 ON 0.0 FeII clear 157 100 ONSKY zero.fits  

  • Recenter: 080928, 081000, 081046, 081116
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170919_081000 ??? 10.7 275460 13 1.00 0.66 b2m153 2 153 991 0.5 0.5 0.2 3 120 ON 27.8 FeII clear 157 100 ONSKY zero.fits  
20170919_081046 ??? 10.7 275537 13 1.03 0.62 b2m153 2 153 991 0.4 0.5 0.1 3 122 ON 33.8 FeII clear 157 100 ONSKY zero.fits  
20170919_081116 ??? 10.7 275585 14 1.03 0.75 b2m153 2 153 991 0.4 0.2 0.2 3 118 ON 28.6 FeII clear 157 100 ONSKY zero.fits  

08:36
  • Closing for humidity

-- %USERSIG{GregoryTaylor - 2017-09-19}%
Topic revision: r10 - 21 Sep 2017, DougMiller
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback