DX Checkout of Recons and NCPA

9:45 Start with alignment (after getting SX aligned for Arcetri guys)

11:00 Closed loop with 400 modes, 990 Hz
  • Hex -2.9, -2.39, 1.02, -128, -218
  • Bayside -73, -54.4, 56.0 (good Focus on LUCI2 N30 camera in FeII)

11:00 save flat
  • Recon flao_v16_b1m400
  • Flat 20170917_400_1.sav
  • 639 modes
  • forces -0.20, 0.17 N

11:25 Telemetry with LUCI
  • Not GOPT, No NCPA
  • 182924

11:31
  • LUCI Dark
  • 183130

11:59 Create new NCPA file ncpa_measured_20170915.dat
  • ln -s ncpa_measured_20170915.dat LUCIFER
  • ln -s ncpa_measured_20170915.dat RETROREF

12:06 Create new disturbance files
  • Example
    • print, sinusmode_generate(4, 10e-9, 30, 990, "KL_v16", /even,
    • add_file="/local/aomeas/adsec_calib/CMD/disturb/old_KL_v16/dist_flao1_ts4_atm_s1.6_L040.0_v15.0_ovfreq1000.00_sd1983.fits")

12:07 CmdDisturb files in
  • 0.0" seeing
    • print, sinusmode_generate(4, 10e-9, 30, 990, "KL_v16", /even)
    • 20170917_190921
    • ln -s ../../M2C/KL_v16/disturb/CmdDisturb_20170917_190921.fits CmdDisturb_v16_4m_990Hz_0.0seeing.fits

12:45 Get Gopt working
  • load TN
  • help, (a->control())->c2m()

12:48 Telemetry
  • rot = 210
  • OptGain = 0.64
  • 194900, 195015, 195149

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170917_194900 ??? 9.4 323998 6 NaN 0.06 b1m400 1 400 990 0.3 0.1 0.1 3 105 ON 52.4 FeII clear 157 20 ONSKY NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Warning: Selected luci dark +1h old!
20170917_195015 ??? 9.4 323998 11 NaN 0.06 b1m400 1 400 990 0.3 0.1 0.1 3 105 ON 53.5 FeII clear 157 20 ONSKY NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Background correction failed - Warning: Selected luci dark +1h old!
20170917_195149 ??? 9.4 323998 7 NaN 0.06 b1m400 1 400 990 0.3 0.1 0.1 3 105 ON 53.6 FeII clear 157 20 ONSKY NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Background correction failed - Warning: Selected luci dark +1h old!

01:12 Create CmdDisturb file with 0.8" seeing for CalUnit
    • print, sinusmode_generate(4, 10e-9, 30, 990, "KL_v16", /even,
    • add_file="/local/aomeas/adsec_calib/CMD/disturb/old_KL_v16/dist_flao1_ts4_atm_s1.6_L040.0_v15.0_ovfreq1000.00_sd1983.fits")
  • 20170917_201154
  • ln -s ../../M2C/KL_v16/disturb/CmdDisturb_20170917_201154.fits CmdDisturb_v16_4m_990Hz_Cal_0.8seeing.fits

01:22 Telemetry 0.8" seeing
  • gain 1.05, 0.75, 0.25
  • gopt = 0.36
  • 202906 no luci data, timeout, slow network?
  • no LUCI image...

01:45 Take 20 darks
  • 204707

01:50 Skip frames, Rip, Failure

02:02 LUCI dark
  • 210202

02:05 0.8" seeing
  • gains 1.25, 0.4, 0.25
  • gopt = 0.34
  • 210903, 211010, 211034

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170917_210943 ??? 9.3 323998 14 NaN 0.89 b1m400 1 400 990 0.4 0.1 0.1 3 112 ON 37.5 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - SR may be in error
20170917_211010 ??? 9.3 323998 7 NaN 0.89 b1m400 1 400 990 0.4 0.1 0.1 3 113 ON 34.7 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - SR may be in error
20170917_211034 ??? 9.3 323998 11 NaN 0.89 b1m400 1 400 990 0.4 0.1 0.1 3 113 ON 37.5 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - SR may be in error

02:20 Bin 2 0.0" Seeing
  • 470 has -0.29 N with flat, only 323 modes
  • gain 0.5, 0.2, 0.2
  • gopt=0.58
  • No NCPA
  • 213155, 213219, 213243
  • NCPA On
  • 213346, 213423, 213443

02:35 Bin 2 0.8" seeing
  • gain 0.85 0.5, 0.35
  • gopt= 0.3
  • NCPA Off
  • 213954, 214012, 214030
  • NCPA On
  • 214121, 214141, 214157

02:48 Create 300Hz CmdDisturb with 0.0" seeing
  • print, sinusmode_generate(4, 10e-9, 30, 300, "KL_v16", /even)
  • 20170917_214831
  • ln -s ../../M2C/KL_v16/disturb/CmdDisturb_20170917_214831.fits CmdDisturb_v16_4m_300Hz_Cal_0.0seeing.fits

02:51 Create 300Hz CmdDisturb with 0.8" seeing
    • print, sinusmode_generate(4, 10e-9, 30, 300, "KL_v16", /even,
    • add_file="/local/aomeas/adsec_calib/CMD/disturb/old_KL_v16/dist_flao1_ts4_atm_s1.6_L040.0_v15.0_ovfreq1000.00_sd1983.fits")
  • 20170917_215205
  • ln -s ../../M2C/KL_v16/disturb/CmdDisturb_20170917_215205.fits CmdDisturb_v16_4m_300Hz_Cal_0.8seeing.fits

02:45 Bin 2 0.0" seeing
  • ARGOS Light = 81, 15.1 mag
  • gain 0.8, 0.4, 0.15
  • gopt = 0.51
  • NCPA Off
  • 220343, 220401, 220421

03:49 Bin 1, 990Hz, 0.0" seeing
  • jump act in when flat applied: 470, 485 at 3:30 position
  • 316 modes applied
  • flat 20170917_400_2.sav
    • 589 modes
  • gain 0.4, 0.2, 0.15
  • Gopt = 0.55
  • NCPA ON
  • No LUCI frames

04:00 LUCI dark
  • 230053

04:09 Create 1.6" seeing dist file for CalUnit
  • multiplied 0.8" file by 2.0 to get dist_calunit_atm_s1.6_L040.0_v15.0_ovfreq1000.00_sd1983.fits
    • print, sinusmode_generate(4, 10e-9, 30, 990, "KL_v16", /even,
    • add_file="/local/aomeas/adsec_calib/CMD/disturb/old_KL_v16/dist_calunit_atm_s1.6_L040.0_v15.0_ovfreq1000.00_sd1983.fits")
  • 20170917_230909
  • ln -s ../../M2C/KL_v16/disturb/CmdDisturb_20170917_230909.fits CmdDisturb_v16_4m_300Hz_Cal_1.6seeing.fits

04:12 bin 1, 990Hz, 1.6" seeing
  • gain 0.8,0.6, 0.3
  • gopt= 0.36
  • NCPA On
  • 231705, 231728, 231753

04:18 bin 1, 400 Mode, 990Hz, 1.6" seeing
  • opt gain 1.7, 0.6, 0.39
  • gopt=0.37
  • NCPA On
  • 232109 fail to get LUCI
  • gain 1.3, 0.6, 0.34
  • gopt=0.37
  • NCPA On
  • 232548, 232623, 232641

04:29 bin 1, 300 Mode, 990Hz, 1.6" seeing
  • opt gain 1.7, 0.6, 0.4
  • gopt=0.33
  • NCPA ON
  • 233423, 233442, 233500

04:37 Apply flat 20170917_400_2.sav
  • 589 modes
  • act 260 force of ~-0.29 N

-- %USERSIG{DougMiller - 2017-09-17}%
Topic revision: r4 - 17 Sep 2017, DougMiller
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback