DX AdSec 4D Vibration Measurements: LUCI Cryo Coolers

11:00 MST Get telescope

11:30 find return beam

12:00 Start alignment
  • AdOpt> print, hexalign(track='20170906_232727')
  • AdOpt> print, opt_int_mat_reduce2(200, track='20170830_123006')

12:45 Aligned
  • hexapod -2.4664 -3.3223 4.8126 -107.54 -559.61

12:55 OVMS data saving turned on

13:00 Test noise data collection

13:11
  • AdOpt> print, i4d_opt_intmat(0,250,amprms=0)
    • Can see shape on mirror and on 4D
    • 20170907_201016
  • AdOpt> print, i4d_opt_intmat(0,250,amprms=0.)
    • Can see shape on mirror and on 4D
    • 20170907_201339
  • AdOpt> print, i4d_opt_intmat(0,250,amprms=1.0)
    • Can see shape on mirror and on 4D
    • 20170907_201516
  • AdOpt> print, i4d_opt_intmat(0,250,amprms=1.0e-9)
    • Can see shape on mirror and on 4D
    • 20170907_201708
  • AdOpt> print, i4d_opt_intmat(0,250,amprms=10.0e-9)
    • Can see shape on mirror and on 4D
    • 20170907_202009
  • AdOpt> print, i4d_opt_intmat(0,250,amprms=1oo.0e-9)
    • Can see shape on mirror and on 4D
    • 20170907_202355
  • AdOpt> print, i4d_opt_intmat(0,20,amprms=10.0e-9)
    • Can see shape on mirror and on 4D
    • 20170907_202539

13:52 Modified make_modal_distrub.pro
  • force it to use the passed minimum value
  • AdOpt> print, i4d_opt_intmat(0,250,amprms=1.0e-9)

13:52 Reference data, Both LUCI's ON
  • 20170907_205243_noise_idl
  • 20170907_205452_noise_idl
  • 20170907_205647_noise_idl
  • 20170907_210334_noise_idl

14:06 LUCI1 OFF and LUCI2 ON
  • 20170907_210522_noise_idl
  • 20170907_210624_noise_idl
  • 20170907_210730_noise_idl

14:10 LUCI1 OFF and LUCI2 OFF
  • 20170907_211015_noise_idl
  • 20170907_211123_noise_idl
  • 20170907_211251_noise_idl
  • 20170907_211300_noise_4d (comm4d.capture)
  • 20170907_211400_noise_4d (comm4d.capture)
  • 20170907_211500_noise_4d (comm4d.capture)

14:19 LUCI1 ON and LUCI2 OFF
  • 20170907_211938_noise_idl
  • 20170907_212048_noise_idl
  • 20170907_212211_noise_idl
  • 20170907_212200_noise_4d (comm4d.capture)
  • 20170907_212300_noise_4d (comm4d.capture)
  • 20170907_212400_noise_4d (comm4d.capture)

14:29 Reference data, Both LUCI's ON
  • 20170907_212958_noise_idl
  • 20170907_213129_noise_idl
  • 20170907_213237_noise_idl
  • 20170907_213200_noise_4d (comm4d.capture)
  • 20170907_213300_noise_4d (comm4d.capture)
  • 20170907_213400_noise_4d (comm4d.capture)

15:07 John's hand on rail mount
  • 20170907_220747_noise_idl
  • 20170907_220853_noise_idl
  • 20170907_220700_noise_4d (comm4d.capture)

15:12 John's hand on 4D box
  • 20170907_221600_noise_4d (comm4d.capture)
  • 20170907_221732_noise_idl
  • 20170907_221840_noise_idl

15:20 Reference data, No hands on 4D
  • 20170907_222027_noise_idl
  • 20170907_222132_noise_idl
  • 20170907_222237_noise_idl
  • 20170907_222200_noise_4d (comm4d.capture)
  • 20170907_222300_noise_4d (comm4d.capture)
  • 20170907_222400_noise_4d (comm4d.capture)

16:10
tn1=['20170907_205243_noise_idl', '20170907_205452_noise_idl', '20170907_205647_noise_idl', '20170907_210334_noise_idl', '20170907_210522_noise_idl', '20170907_210624_noise_idl', '20170907_210730_noise_idl', '20170907_211015_noise_idl', '20170907_211123_noise_idl', '20170907_211251_noise_idl']

tn2=['20170907_211300_noise_4d', '20170907_211400_noise_4d', '20170907_211500_noise_4d', '20170907_211938_noise_idl', '20170907_212048_noise_idl', '20170907_212211_noise_idl', '20170907_212200_noise_4d', '20170907_212300_noise_4d', '20170907_212400_noise_4d', '20170907_212958_noise_idl']

tn3=['20170907_213129_noise_idl', '20170907_213237_noise_idl', '20170907_213200_noise_4d', '20170907_213300_noise_4d', '20170907_213400_noise_4d', '20170907_220747_noise_idl', '20170907_220853_noise_idl', '20170907_220700_noise_4d', '20170907_221600_noise_4d', '20170907_221732_noise_idl']

tn4=['20170907_221840_noise_idl', '20170907_222027_noise_idl', '20170907_222132_noise_idl', '20170907_222237_noise_idl', '20170907_222200_noise_4d', '20170907_222300_noise_4d', '20170907_222400_noise_4d']

-- %USERSIG{DougMiller - 2017-09-07}%
Topic revision: r2 - 08 Sep 2017, DougMiller
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback