Measure SX FF Matrix and Flatten with 4d

21:07 Tested new 5 iteration FF matrix
  • Looks good at least in terms of flatness (no bumps around outside edge)
  • Only 202 modes with new FF were had 572 with old FF
  • new flat with 4D should give and improve flat (shapes, bumps) and lower forces.
  • Sent email to AO group on Sunday, Aug. 27 at 1:58 pm "New FF Matrix on SX looks good"

21:11 Checked configuration file $ADOPT_ROOT/calib/adsec/current/scripts/ff_acquire_default.tst
  • n_cycles = 20
  • file names are given (no "")
  • modal with FF

21:30 Elevation drives are locked out
  • kill adsecarb process
  • enable_lab_mode.sh

21:30
  • AdOpt> print, fsm_rip()
  • AdOpt> print, fsm_set_flat(/ff, /no_flat)
  • AdOpt> print, collect_noise_data()
  • Data saved in: /local/aomeas/adsec_calib/noise/20170827_213323/noise_lin.sav

21:34
  • $ aoidl
  • IDL> @startup
  • IDL> restore, /VERB, "/local/aomeas/adsec_calib/noise/20170827_213323/noise_lin.sav"
  • IDL> sigma_pos_reb = sqrt(rebin(sigma_pos^2, 672, 1))
  • IDL> display, sigma_pos_reb, /SH, /NO_NUM
  • image
  • IDL> display, sigma_pos_reb[adsec.act_w_pos], adsec.act_w_pos, /SH, /NO_NUM, MIN_V=4e-9
  • IDL> print, where(sigma_pos_reb[adsec.act_w_pos] GT 5.e-9)
  • 540
  • IDL> print, adsec.act_w_pos[540]
  • 550
  • IDL> print, sigma_pos_reb[550]
  • 5.0834261e-09
  • Actuator 550 is near the limit to leave in pos use. Will measure 20 iteration FF and see what its noise looks like.
  • Need to correct FF document to use adsec.act_w_pos variable

22:12 Measure 20 iteration FF Matrix
  • AdOpt> tn=tracknum()
  • AdOpt> print, tn
  • 20170827_221420
  • AdOpt> print, ff_acquire_v2(tn)
    • => should have taking an offset before starting
    • => will try to take offset when first iteration is done
  • Took offset and now pos display looks better

00:30
  • AdOpt> print, reduce_ff_data('20170827_221420', /DO_PLOT)
  • normalized chi^2 ff_matrix: 136
  • images

01:31 copy new ff .fits files to data directory used
  • cp /local/aomeas/adsec_calib/ff_matrix/20170827_221420/*.fits /home/aoeng/act_add/calib/adsec/current/data/.

[AOeng@sxadsec 20170827_055121]$ ls -ltr /home/aoeng/act_add/calib/adsec/current/data/
total 56512
-rw-r--r--. 1 AOeng aoeng    14400 May  2 15:06 pbgainmatrix.fits
-rw-r--r--. 1 AOeng aoeng     2412 May  2 15:06 astig_lut.sav
-rw-r--r--. 1 AOeng aoeng     3104 May  2 15:06 astig_lut_orig.sav
-rw-r--r--. 1 AOeng aoeng   123840 May  2 15:06 pmz.fits
-rw-r--r--. 1 AOeng aoeng   123840 May  2 15:06 pmz_old.fits
-rw-r--r--. 1 AOeng aoeng     2412 May  2 15:06 astig_lut_0.sav
-rw-r--r--. 1 AOeng aoeng  3617280 May  2 15:06 pmhofor.fits
-rw-r--r--. 1 AOeng aoeng  3617280 May  2 15:06 null_pmhofor.fits
-rw-r--r--. 1 AOeng aoeng 27673900 May  2 15:06 layer_phi_000000_time_hist_armando_672a.sav
-rw-r--r--. 1 AOeng aoeng  4305600 Aug 28 00:10 b0_a_matrix.fits
-rw-r--r--. 1 AOeng aoeng  4305600 Aug 28 00:10 b0_b_matrix.fits
-rw-r--r--. 1 AOeng aoeng  3617280 Aug 28 00:10 a_delay_matrix.fits
-rw-r--r--. 1 AOeng aoeng  3467520 Aug 28 01:31 ff_f_svec.fits
-rw-r--r--. 1 AOeng aoeng     5760 Aug 28 01:31 ff_list.fits
-rw-r--r--. 1 AOeng aoeng  3467520 Aug 28 01:31 ff_matrix.fits
-rw-r--r--. 1 AOeng aoeng  3467520 Aug 28 01:31 ff_p_svec.fits
-rw-r--r--. 1 AOeng aoeng     8640 Aug 28 01:31 ff_sval.fits


[AOeng@sxadsec 20170827_055121]$ cd /home/aoeng/act_add/calib/adsec/current
[AOeng@sxadsec current]$ ls
CMD  data  data_orig  flat  M2C  trash
[AOeng@sxadsec current]$ cp -R data data_20170828_20_iter
[AOeng@sxadsec current]$ ls -ltr
total 20
drwxr-xr-x. 2 AOeng aoeng 4096 May  2 15:06 data
drwxr-xr-x. 3 AOeng aoeng 4096 May  2 15:06 trash
lrwxrwxrwx. 1 AOeng aoeng   29 May  2 15:06 CMD -> /local/aomeas/adsec_calib/CMD
lrwxrwxrwx. 1 AOeng aoeng   29 May  2 15:06 M2C -> /local/aomeas/adsec_calib/M2C
drwxr-xr-x. 2 AOeng aoeng 4096 May  2 15:06 flat
drwxr-xr-x. 2 AOeng aoeng 4096 Aug 27 05:32 data_orig
drwxr-xr-x. 2 AOeng aoeng 4096 Aug 28 01:34 data_20170828_20_iter

01:36 Stop and start adsec processes
  • Set Shell
  • flat 20170710_400_1.sav
  • 230 modes
  • Highest current of -0.29 at act 6. This was added back in use of the FF matrix. Then next highest force actuator was at -0.15. Hopefully new flat will improve this

01:58 FF matrix measurement complete for SX
  • Must copy the new ff .fits files to svn

-- %USERSIG{DougMiller - 2017-08-27}%
Topic revision: r2 - 28 Aug 2017, DougMiller