Summary of DX Daytime work over the the last few months

21-25 April 2017: Tip/Tilt LUT Measurements

2-9 May 2017: Add Actuators back into use

9 May 2017: Test Old Bin 1, 300 and 400 mode Reconstructors (CalUnit)

  • 300 mode Recon 012542
    • NCPA On
    • 41-44% Strehl
    • 20170509_231308
  • 400 mode Recon: 014135
    • NCPA On
    • 61% Strehl
    • 20170509_212640

25 May 2017: Check old 300 mode Recon performance and NCPA at 40 elevation (CalUnit)

  • Old Bin 1, 300 Mode Recon
    • NCPA Off
      • 20170525_192040, 20170525_192116, 20170525_192240, 20170525_192302, 20170525_192328
    • NCPA On
      • 20170525_192434, 20170525_192452, 20170525_192515, 20170525_192534, 20170525_192550

30 May 2017: Check Focal Plane Wobble and NCPA at 65 elevation (CalUnit)

1 June 2017: Check NCPA at 40 and 65 elevation (CalUnit)

2 June 2017: Measure New Feed Forward Matrix: 5 and 10 iterations

  • Base directory /home/aoeng/act_add/calib/adsec/current
    • ./data_old Original FF
    • ./data_5 New 5 iteration FF
    • ./data_10 New 10 iteration FF

12 June 2017: Measure New Recons with New FF (5 iter) (RR)

  • 48 iteration Recon: 203644
    • 1.2" Seeing, NCPA Off
      • 20170612_204535, 20170612_204625, 20170612_204641, 20170612_204655
    • 1.5" Seeing, NCPA Off
      • 20170612_205035, 20170612_205115, 20170612_205130, 20170612_205146
    • 0.8" Seeing, NCPA Off
      • 20170612_222518, 20170612_222541, 20170612_222609, 20170612_222626
    • 0.8" Seeing, NCPA On
      • 20170612_223215, 20170612_223231, 20170612_223247, 20170612_223307

13 June 2017: Measure New Recons with New FF (5 and 10 iter) (RR)

  • 5 Iteration FF Matrix
    • 48 iteration Recon: 175001
      • 0.8" seeing
        • NCPA Off
          • 20170613_184834, 20170613_184852, 20170613_184909, 20170613_185019
        • NCPA On
          • 20170613_185322, 20170613_185517, 20170613_185535, 20170613_185552
      • 1.0" seeing
        • NCPA Off
          • 20170613_190135, 20170613_190153, 20170613_190215, 20170613_190240
        • NCPA On
          • 20170613_190347, 20170613_190407, 20170613_190432, 20170613_190454
      • 1.2" seeing
        • NCPA Off
          • 20170613_190910, 20170613_190928, 20170613_191011, 20170613_191031
        • NCPA On (Failed: Edge rolled when NCPA applied)
  • 10 Iteration FF Matrix (HBS Off)
    • 4 iteration Recon: 211604
      • 0.8" seeing
        • NCPA Off
          • 20170613_212305, 20170613_212416, 20170613_212437, 20170613_212459
        • NCPA On
          • 20170613_212919, 20170613_212938, 20170613_213004, 20170613_213027
      • 1.0" seeing
        • NCPA Off
          • 20170613_213223, 20170613_213240, 20170613_213301, 20170613_213320
        • NCPA On
          • 20170613_213358, 20170613_213419, 20170613_213439, 20170613_213524
      • 1.2" seeing
        • Failed for any HO2: HBS was Off
      • 1.2" seeing
        • NCPA Off, HBS On
          • 20170613_224326, 20170613_224342, 20170613_224359, 20170613_224421
    • 48 iteration Recon: 231742
      • 1.2" seeing
        • NCPA Off, HBS On
          • 20170613_232202, 20170613_232222, 20170613_232240, 20170613_232258
        • NCPA On, HBS On
          • 20170613_232416, 20170613_232435, 20170613_232453, 20170613_232517

14 June 2017: Measure New Recons with New FF (10 iter) Bin 1, 2, 3, 4 (RR)

Bin 1
  • Bin 1, 48 iteration Recon: 190540
    • Test with 0.8" seeing
      • NCPA Off
        • 20170614_192525, 20170614_192544, 20170614_192605, 20170614_192623
      • NCPA On
        • 20170614_192945, 20170614_193011, 20170614_193027, 20170614_193053
    • Test with 1.0" seeing
      • NCPA Off
        • 20170614_193401, 20170614_193420, 20170614_193438, 20170614_193456
  • Bin 1, 96 iteration Recon: 210010
    • Test with 1.0" seeing
      • GOPT Off
        • 20170614_201721, 20170614_201737, 20170614_201803, 20170614_201820
    • Test with 1.2" seing
      • GOPT Off
        • 20170614_202220, 20170614_202238, 20170614_202255, 20170614_202311
      • GOPT On, NCPA Off
        • 20170614_202343, 20170614_202359, 20170614_202440, 20170614_202502
Bin 2
  • Bin 2
    • Test with 1.2" seeing
      • NCPA Off, 4 Iteration Recon 215414
        • 20170614_215803, 20170614_215818, 20170614_215833, 20170614_215845
      • With LUCI images, 48 iteration Recon: 222920
        • 20170614_223334, 20170614_223400, 20170614_223418, 20170614_223433
Bin 3
  • Bin 3, 48 iteration Recon: 225826
    • Test with 1.2" seeing
      • NCPA Off
        • 20170614_230256, 20170614_230325, 20170614_230402, 20170614_230423
Bin 4
  • Bin 4, 48 iteration Recon: 232600
    • Test with 1.2" seeing
      • NCPA Off
        • 20170614_233021, 20170614_233059, 20170614_233121, 20170614_233144

29 June 2017: Test New Recon using New FF (10 iter) (RR)

  • 10 Iteration FF Matrix Recon: ??
    • HBS Off, No NCPA
      • With LUCI images: 20170629_113238
    • HBS On, No NCPA
      • With LUCI images: 20170629_114707

30 June 2017: Test New Recon using New FF (5 iter) (RR)

  • 5 Iteration FF Matrix Recon: 175001
    • HBS On
      • No Seeing
        • 20170630_091518
      • 0.8" Seeing
        • 20170630_092158
    • HBS Off
      • No Seeing
        • 20170630_095353, 20170630_095548
      • 0.8" Seeing
        • 20170630_095147
  • 10 Iteration FF Matrix Recon: 231742
    • Rotated RetroCube to original position
      • HBS Off
        • No Seeing
          • 20170630_101814
        • 0.8" seeing
          • 20170630_103442
        • 0.8" seeing
          • LUCI Images
          • NCPA Off
          • 20170630_110735
          • 17% Strehl in P-Beta
      • HBS On
        • 0.8" seeing
          • LUCI Images
          • NCPA Off
          • 18% Strehl in P-Beta
          • 20170630_111430

1 July 2017: New Recon Performance Bin 1, 2, 3 and 4 (CalUnit)

  • Bin 1
    • Rec: 231742
    • 0.8"/2 Seeing
      • 990 Hz
      • 9.4 mag
      • Gopt = 0.5
      • NCPA On
      • 20170701_082903, 20170701_083006, 20170701_083021, 20170701_083042, 20170701_083121
      • 66-68 % Strehl in FeII
    • 1.2"/2 Seeing
      • 990 Hz
      • 9.4 mag
      • Gopt = 0.42
      • NCPA On
      • 20170701_095414, 20170701_095437, 20170701_095452, 20170701_095522, 20170701_095540
      • 60-62% Strehl in FeII
  • Bin 2
    • Rec 222920
    • 1.2"/2 Seeing
      • 990 Hz
      • 9.0 mag
        • NCPA Off
          • 20170701_104802, 20170701_104823, 20170701_104838, 20170701_104853, 20170701_104908
          • 40-43% Strehl in FeII
        • NCPA On
          • Gopt = 0.5
          • 20170701_105012, 20170701_105027, 20170701_105042, 20170701_105057, 20170701_105112
          • 55-56% Strehl in FeII
      • 11.7 mag
        • NCPA Off
          • 20170701_111202, 20170701_111222, 20170701_111237, 20170701_111254, 20170701_111309
          • % Strehl in FeII
        • NCPA On
          • Gopt = 0.5
          • 20170701_111921, 20170701_111943, 20170701_112005, 20170701_112028, 20170701_112050
          • % Strehl in FeII
  • Bin 3
    • Rec 225826
    • 1.2"/2 Seeing
      • 500 Hz
      • 14.2 mag
        • NCPA Off
        • 20170701_114315, 20170701_114342, 20170701_114424, 20170701_114439, 20170701_114504
        • NCPA Set Manually (for roundest image)
        • 20170701_114917, 20170701_115001, 20170701_115019, 20170701_115038, 20170701_115053
  • Bin 4
    • Rec: 232600
    • 1.2"/2 Seeing
      • 200 Hz
      • 15.6 mag
      • NCPA Off
      • 20170701_121805, 20170701_121830, 20170701_121853, 20170701_121916, 20170701_121940
      • % Strehl in FeII

2 July 2017: New Recon Performance, TT LUT Calibration for various CL frequencies (CalUnit)

  • New Bin1 400 mode Recon performance
    • New FF, 10 Iterations
    • Rec_20170613_231742
    • 0.8"/2 Seeing
    • Gains
      • Manual 1.0, 0.5, 0.3
        • GOPT 0.42
        • NCPA On
        • 20170702_053413, 20170702_053809, 20170702_053835, 20170702_053938, 20170702_053953
        • 59-62% Strehl in FeII
      • Optimized 1.23, 0.54, 0.3
        • GOPT 0.41
        • NCPA On
        • 20170702_061937, 20170702_061954, 20170702_062033, 20170702_062047, 20170702_062103
        • 65-66% Strehl in FeII
  • TT LUT Calibration
    • 990 Hz
    • 600 Hz
    • 400 Hz
    • 200 Hz
    • 105 Hz

3 July 2017: Rename Reconstructors (CalUnit)

  • Created 12 mode Reconstructors
  • Copied all old Reconstructors to old directory
  • Symbolic Links
    • Intmat_flao_v16_b1m12.fits -> flao/Intmat_20170703_100242.fits
    • Intmat_flao_v16_b1m300.fits -> flao/Intmat_20170703_113633.fits
    • Intmat_flao_v16_b1m400.fits -> flao/Intmat_20170613_231742.fits
    • Intmat_flao_v16_b2m12.fits -> flao/Intmat_20170703_103040.fits
    • Intmat_flao_v16_b2m156.fits -> flao/Intmat_20170614_222920.fits
    • Intmat_flao_v16_b3m12.fits -> flao/Intmat_20170703_110617.fits
    • Intmat_flao_v16_b3m66.fits -> flao/Intmat_20170614_225826.fits
    • Intmat_flao_v16_b4m12.fits -> flao/Intmat_20170703_112809.fits
    • Intmat_flao_v16_b4m36.fits -> flao/Intmat_20170614_232600.fits
    • Rec_flao_v16_b1m12.fits -> flao/Rec_20170703_100242.fits
    • Rec_flao_v16_b1m300.fits -> flao/Rec_20170703_113633.fits
    • Rec_flao_v16_b1m400.fits -> flao/Rec_20170613_231742.fits
    • Rec_flao_v16_b2m12.fits -> flao/Rec_20170703_103040.fits
    • Rec_flao_v16_b2m153.fits -> flao/Rec_20170614_222920.fits
    • Rec_flao_v16_b3m12.fits -> flao/Rec_20170703_110617.fits
    • Rec_flao_v16_b3m66.fits -> flao/Rec_20170614_225826.fits
    • Rec_flao_v16_b4m12.fits -> flao/Rec_20170703_112809.fits

4 July 2017: Create and Test AO Reconstructor Tables (CalUnit)

  • table_LUCIFER_ACE-AO.txt
  • table_LUCIFER_ACE-AO.badseeing.txt
  • table_LUCIFER_TTM-AO.txt