DX AO Table Creation and Testing

05:35 Try to close loop: No Slope arriving at AdSec
  • Stop/Start Slope Computer process
    • CCD39 go "Not Live"
    • Had to change loop parameter (bin 1 to 2 then back): OK
    • No Slopes
  • Stop/Start BCU interface process
    • Lose communication to Slope Computer
    • Both CCD39 and CCD47 go to "Not Live"
    • Had to change loop parameter (bin 1 to 2 then back): OK
    • Change binning on CCD47 on the HW GUI
    • Error in BCU interface log
            MirrorCtrl_42765   |ERR|       122|2017-07-03 05:44:29.056189| BCUCOMMANDHANDLER_1_P3 > Client timed-out: impossible to attach to the shared memory !
            MirrorCtrl_42765   |ERR|       123|2017-07-03 05:44:29.056241| BCUCOMMANDHANDLER_1_P3 > BcuCommandHandler::handleBcuRequest: REQUEST FAILED
    • No Slopes
    • Stop/Start Slope Computer process
      • CCD39 go "Not Live"
      • Had to change loop parameter (bin 1 to 2 then back): OK
      • No Slopes
  • Power off WUnit and stop/start
    • Slopes OK

06:10 Closed Loop
  • Try Optimize Gain: Failed with safe skip

06:20 Close loop
  • Manual gains 1.1, 0.4 0.15
  • flat 20170703_400_1 and _2
  • Optimize gain procedes further, but still get skip frame

06:44 Close Loop with Gopt
  • 9.1 mag
  • bin 1
  • 990 Hz
  • Recon 20170613_231742
  • Gain 1.1, 0.4, 0.15 manual
  • Gopt = 0.51
  • NCPA On

06:58 Get Remote images from LUCI
  • Successfully get Dark image from LUCI using "Acquire PISCES Dark" button 20170703_065811
  • Dark 065932
  • Start "Endless" mode on GEIRS GUI
  • Stop "Endless"
  • Dark 070136
  • Close loop
  • Gains 1.1, 0.4, 0.15 manually
  • Gopt = 0.5
  • NCPA on
  • Opt Loop Data with LUCI images
    • 070424, 070452, 070507, 070522, 070537
  • Optimize Gain 1.23, 0.15, 0.19
  • Opt Loop Data with LUCI images
    • 070759 "Error saving optical loop data" Box pop up
    • 070845 "Error saving optical loop data" Box pop up
  • Open Loop
  • Stop/Start WFSARB via process GUI
  • Apply loop params
  • Gains 1.1, 0.4, 0.15 manually
  • Optical Loop Data with LUCI images
    • 071134 Success
    • 071206 Success
  • Optimize Gain:Failed with Save skip
  • Close Loop
  • Gains 1.1, 0.4, 0.15 manually
  • Optical Loop Data with LUCI images
    • 071507 "Error saving optical loop data" Box pop up
    • Read 1 image via GEIRS GUI
    • 071603 "Error saving optical loop data" Box pop up
  • Open Loop
  • Stop/Start WFSARB via process GUI
  • Apply loop params
  • Gains 1.1, 0.4, 0.15 manually
  • Optical Loop Data with LUCI images
    • 071759 Success
  • Optimize Gain:Failed with Save skip
    • Kill IDL Graph from Opt Gain
  • Close Loop
  • Gains 1.1, 0.4, 0.15 manually
  • Optical Loop Data with LUCI images
    • 072052 "Error saving optical loop data" Box pop up
  • Open Loop
  • Stop/Start WFSARB via process GUI
  • Apply loop params
  • Gains 1.1, 0.4, 0.15 manually
  • Optical Loop Data with LUCI images
    • 072235 Success

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170703_070424 ??? 9.3 323982 5 NaN 0.08 231742 1 400 990 0.6 0.2 0.1 3 115 ON 72.9 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error
20170703_070452 ??? 9.3 323982 4 NaN 0.08 231742 1 400 990 0.6 0.2 0.1 3 115 ON 71.6 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error
20170703_070507 ??? 9.3 323982 5 NaN 0.08 231742 1 400 990 0.6 0.2 0.1 3 116 ON 71.5 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error - Background correction failed
20170703_070522 ??? 9.3 323982 5 NaN 0.08 231742 1 400 990 0.6 0.2 0.1 3 115 ON 72.8 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error
20170703_070537 ??? 9.3 323982 4 NaN 0.08 231742 1 400 990 0.6 0.2 0.1 3 115 ON 71.2 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error

  • 070424 Plots:
    070424_psf.jpg
  • 070424 Plots:
    070424_modal.jpg
  • 070424 Plots:
    070424_jitter.jpg

07:34 Close loop with 0.8"/2 seeing
  • 0.8"/2 /local/aomeas/adsec_calib/M2C/KL_v16/disturb/CmdDisturb_20170613_184455.fits
  • Gains 1.1, 0.4, 0.15 manually
  • Gopt = 0.4
  • NCPA On
  • 073628, 073644, 073658, 073751, 073806
  • Optimize Gain Failed with safe skip on HO2
  • Close loop
  • Gains 1.1, 0.4, 0.15 manually
  • 074313 "Error saving optical loop data" Box pop up
  • Open Loop
  • Stop/Start WFSARB via process GUI
  • Apply loop params
  • Gains 1.1, 0.4, 0.15 manually
  • Optical Loop Data with LUCI images
  • Gopt= 0.4
  • NCPA On
  • 074551, 074606

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170703_073628 ??? 9.3 323982 3 NaN 0.39 231742 1 400 990 0.5 0.2 0.1 3 119 ON 63.4 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error - Background correction failed
20170703_073644 ??? 9.3 323982 3 NaN 0.39 231742 1 400 990 0.5 0.2 0.1 3 118 ON 64.5 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error
20170703_073658 ??? 9.3 323982 3 NaN 0.39 231742 1 400 990 0.5 0.2 0.1 3 118 ON 65.6 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error
20170703_073751 ??? 9.3 323982 3 NaN 0.40 231742 1 400 990 0.5 0.2 0.1 3 118 ON 64.5 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error
20170703_073806 ??? 9.3 323982 4 NaN 0.40 231742 1 400 990 0.5 0.2 0.1 3 118 ON 63.6 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error - Background correction failed
20170703_074551 ??? 9.3 323982 3 NaN 0.39 231742 1 400 990 0.5 0.2 0.1 3 117 ON 66.8 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error
20170703_074606 ??? 9.3 323982 4 NaN 0.39 231742 1 400 990 0.5 0.2 0.1 3 117 ON 65.5 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error

  • 074551 PSF:
    074551_psf.jpg

Clean Up AdSec Directories

08:00 Reconstructor directory
  • cd /local/aomeas/adsec_calib/M2C/KL_v16/RECs
  • mkdir old
  • mv * old/.
  • find old -name \*231742\* -exec cp {} . \;
  • ln -s Rec_20170613_231742.fits Rec_flao_bin4_400modes.fits
% ls -1
Intmat_20170613_231742.fits
Intmat_20170613_231742.fits_data.sav
Intmat_20170613_231742.fits_saturation.sav
old
Rec_20170613_231742.fits
Rec_flao_bin4_400modes.fits
  • Closed the loop with Rec_flao_bin4_400modes.fits

08:28 Closed loop with Rec_flao_bin4_400modes.fits
  • Make sure ELAB still works with new name
  • 802841, 083001, 083016

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170703_082841 ??? 9.3 323982 3 NaN 0.39 _400mo 1 400 990 0.5 0.2 0.1 3 117 ON 65.9 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error - Warning: Selected luci dark +1h old!
20170703_083001 ??? 9.3 323982 3 NaN 0.38 _400mo 1 400 990 0.5 0.2 0.1 3 117 ON 62.6 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error - Warning: Selected luci dark +1h old!
20170703_083016 ??? 9.3 323982 3 NaN 0.38 _400mo 1 400 990 0.5 0.2 0.1 3 117 ON 63.3 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error - Warning: Selected luci dark +1h old!

  • Don't like the Rec name in the table
  • Rename the symbolic link to the reconstructor
  • ln -s Rec_20170613_231742.fits Rec_flao_v16_b4m400.fits

08:47 Closed loop with Rec_flao_v16_b4m400.fits
  • 085021, 085038, 085052

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170703_085021 ??? 9.3 323982 6 NaN 0.39 b4m400 1 400 990 0.5 0.2 0.1 3 116 ON 62.0 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error - Warning: Selected luci dark +2h old!
20170703_085038 ??? 9.3 323982 5 NaN 0.39 b4m400 1 400 990 0.5 0.2 0.1 3 117 ON 62.2 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error - Warning: Selected luci dark +2h old!
20170703_085052 ??? 9.3 323982 4 NaN 0.39 b4m400 1 400 990 0.5 0.2 0.1 3 115 ON 65.2 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error - Warning: Selected luci dark +2h old!

  • Much better, except is b1 no b4. Will re-link
  • mkdir flao
  • cp old/*231742* flao/.

09:00 Closed loop with Rec_flao_v16_b4m400.fits
  • 090020, 090139, 090154

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170703_090020 ??? 9.3 323982 5 NaN 0.39 b1m400 1 400 990 0.5 0.2 0.1 3 117 ON 63.8 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error - Warning: Selected luci dark +2h old!
20170703_090139 ??? 9.3 323982 4 NaN 0.39 b1m400 1 400 990 0.5 0.2 0.1 3 114 ON 62.8 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error - Warning: Selected luci dark +2h old!
20170703_090154 ??? 9.3 323982 5 NaN 0.38 b1m400 1 400 990 0.5 0.2 0.1 3 114 ON 64.1 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error - Warning: Selected luci dark +2h old!

09:10 Gopt must use the Recon name that is in the "Rec matrix" Browse box rather than the one actually loaded.
  • I opened the browse Rec field and then canceled
  • The Browse box then did not have a Rec name, just a directory
  • The Gopt routine must use that file path because it then return divid by zero error for calculation of Gopt value
  • Gopt then went to 1.04, which is too high of gain.
  • Loop opened
  • Then actuator 479 had high current.
  • Load Flat did not fix, only 84 modes applied
  • Rest
  • Apply good flat and get 643 modes

09:20 Disturbance directory
  • cd /local/aomeas/adsec_calib/CMD/disturb
  • ln -l ../../M2C/KL_v16/disturb/CmdDisturb_20170613_184455.fits CalUnit_gopt990_seeing0.4.fits

09:40 Closed loop bin 1 400 modes
  • 094023, 094107, 094139

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170703_094023 ??? 9.3 323982 5 NaN 0.40 b1m400 1 400 990 0.4 0.2 0.1 3 113 ON 62.8 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error - Warning: Selected luci dark +3h old!
20170703_094107 ??? 9.3 323982 6 NaN 0.38 b1m400 1 400 990 0.4 0.2 0.1 3 114 ON 63.8 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error - Background correction failed - Warning: Selected luci dark +3h old!
20170703_094139 ??? 9.3 323982 5 NaN 0.38 b1m400 1 400 990 0.4 0.2 0.1 3 114 ON 59.4 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error - Background correction failed - Warning: Selected luci dark +3h old!

Create 12 mode reconstructors

Bin 1

09:56 Bin 1
  • Intmat 20170613_230329
  • enter 11 modes
  • 12 mode Rec_20170703_100242.fits
  • mv 100242 flao
  • ln -s Rec_20170713_100242.fits Rec_flao_v16_b1m12.fits

10:10 Closed loop, b1m12
  • Gain 1.1, 0.5, 0.4 manual
  • 101059, 101115, 101130

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170703_101059 ??? 9.3 323981 7 NaN Inf b1m12. 1 12 990 1.1 0.5 -1.0 3 112 ON 57.9 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error - Warning: Selected luci dark +3h old!
20170703_101115 ??? 9.3 323981 6 NaN Inf b1m12. 1 12 990 1.1 0.5 -1.0 3 112 ON 58.6 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error - Background correction failed - Warning: Selected luci dark +3h old!
20170703_101130 ??? 9.3 323981 7 NaN Inf b1m12. 1 12 990 1.1 0.5 -1.0 3 112 ON 58.8 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error - Background correction failed - Warning: Selected luci dark +3h old!

10:13 Closed Loop, b1m12
  • 0.4" seeing
  • Gain 1.1, 0.5, 0.4 manual
  • Gopt = 0.36
  • NCPA On: Loop immediately Opens
  • *Can not have NCPA on with ESM*

11:35 Bin 1
  • Intmat 20170613_230329
  • enter 299 modes
  • 300 mode Rec_20170703_113633.fits
  • mv 100242 flao
  • ln -s Rec_20170713_113633.fits Rec_flao_v16_b1m300.fits

11:44 CL with b1m300
  • 0.4" seeing
  • gain 1.25, 0.4, 0.15 Manual
  • opt = 0.4
  • 114919, 114938, 114954, 115011, 115026

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170703_114919 ??? 9.2 323981 7 NaN 0.37 b1m300 1 300 990 0.5 0.1 0.1 3 133 ON 61.2 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Warning: Selected luci dark +5h old!
20170703_114938 ??? 9.1 323981 7 NaN 0.37 b1m300 1 300 990 0.5 0.1 0.1 3 133 ON 60.6 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Background correction failed - Warning: Selected luci dark +5h old!
20170703_114954 ??? 9.1 323981 7 NaN 0.37 b1m300 1 300 990 0.5 0.1 0.1 3 133 ON 63.0 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Warning: Selected luci dark +5h old!
20170703_115011 ??? 9.1 323981 7 NaN 0.37 b1m300 1 300 990 0.5 0.1 0.1 3 133 ON 61.6 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Background correction failed - Warning: Selected luci dark +5h old!
20170703_115026 ??? 9.1 323981 7 NaN 0.37 b1m300 1 300 990 0.5 0.1 0.1 3 133 ON 62.2 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Warning: Selected luci dark +5h old!

Bin 2

10:25 Closed Loop b2m156
  • 990Hz
  • 0.4 Seeing
  • gains 1.3, 0.4, 0.25 manually
  • Gopt = 0,.49
  • NCPA On
  • 102737, 102752, 102808

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170703_102737 ??? 9.3 323981 6 NaN 0.52 b2m156 2 153 991 0.6 0.2 0.1 3 460 ON 54.7 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error - Warning: Selected luci dark +3h old!
20170703_102752 ??? 9.3 323981 7 NaN 0.46 b2m156 2 153 991 0.6 0.2 0.1 3 460 ON 65.2 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error - Warning: Selected luci dark +3h old!
20170703_102808 ??? 9.3 323981 7 NaN 0.45 b2m156 2 153 991 0.6 0.2 0.1 3 460 ON 64.0 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error - Warning: Selected luci dark +3h old!

  • Open Loop
  • actuator 469 has high current
  • 422 modes used for flat

10:19 Bin 2
  • Intmat 20170614_221600
  • enter 11 modes
  • 12 mode Rec_20170703_103040
  • mv 103040 flao
  • ln -s Rec_20170703_103040.fits Rec_flao_v16_b2m12.fits

10:39 CL with b2m12
  • gains 1.05, 0.45, 0.20

Bin 3

11:00 Closed Loop b3m66
  • 500Hz
  • no seeing
  • 14.1 mag (lamp 85)
  • gains 0.9, 0.10, 0.10 manually
  • NCPA set manually z5=-20
  • 110514, 110531, 110546

11:05 Bin 3
  • Intmat 20170614_224411
  • enter 11 modes
  • 12 mode Rec_20170703_110617
  • mv 110617 flao
  • ln -s Rec_20170713_110617.fits Rec_flao_v16_b3m12.fits
  • Closed loop OK

Bin 4

11:00 Closed Loop b4m36
  • 200Hz
  • no seeing
  • 14.8 mag (lamp 81)
  • gains 0.7, 0.10, 0.10 manually
  • 112002, 200020020

11:19 Bin 4
  • Intmat 20170614_231236
  • enter 11 modes
  • 12 mode Rec_20170703_112809
  • mv \*112809\* flao
  • ln -s Rec_20170713_112809.fits Rec_flao_v16_b4m12.fits
  • Closed Loop OK

-- %USERSIG{DougMiller - 2017-07-03}%

  • 114954 PLOTS:
    114954_psf.jpg

  • 114954 PLOTS:
    114954_jitter.jpg
I Attachment Action Size Date Who Comment
070424_jitter.jpgjpg 070424_jitter.jpg manage 111 K 03 Jul 2017 - 07:30 DougMiller 070424 Plots
070424_modal.jpgjpg 070424_modal.jpg manage 77 K 03 Jul 2017 - 07:30 DougMiller 070424 Plots
070424_psf.jpgjpg 070424_psf.jpg manage 138 K 03 Jul 2017 - 07:30 DougMiller 070424 Plots
074551_psf.jpgjpg 074551_psf.jpg manage 127 K 03 Jul 2017 - 07:49 DougMiller 074551 PSF
114954_jitter.jpgjpg 114954_jitter.jpg manage 112 K 03 Jul 2017 - 12:12 DougMiller 114954 PLOTS
114954_psf.jpgjpg 114954_psf.jpg manage 125 K 03 Jul 2017 - 12:12 DougMiller 114954 PLOTS
Topic revision: r3 - 03 Jul 2017, DougMiller
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback