TT LUT Measurements with ARGOS CalUnit

04:45 Start up DX AO System

05:15 Loop Closed

05:36 CL Telemetry
  • Bin 1
  • 990 Hz
  • 9.0 Mag
  • Recon 20170613_231742 (New FF, 10 iter)
  • 0.8"/2 /local/aomeas/adsec_calib/M2C/KL_v16/disturb/CmdDisturb_20170613_184455.fits
  • gains 1.0, 0.5, 0.3 manual
  • Gopt = 0.42
  • NCPA On
  • 053413, 053809, 053835, 053938, 053953

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170702_053413 ??? 9.2 323982 9 NaN 0.39 231742 1 400 990 0.5 0.2 0.1 3 125 ON 59.5 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error - Background correction failed
20170702_053809 ??? 9.2 323982 8 NaN 0.39 231742 1 400 990 0.5 0.2 0.1 3 123 ON 61.7 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error - Background correction failed
20170702_053835 ??? 9.2 323982 9 NaN 0.39 231742 1 400 990 0.5 0.2 0.1 3 124 ON 60.9 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error
20170702_053938 ??? 9.2 323982 8 NaN 0.38 231742 1 400 990 0.5 0.2 0.1 3 124 ON 61.9 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error - Background correction failed
20170702_053953 ??? 9.2 323982 9 NaN 0.39 231742 1 400 990 0.5 0.2 0.1 3 124 ON 61.2 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error

  • 053938:
    053938_psf.jpg
  • 053938:
    053938_modal.jpg
  • 053938 Plots:
    053938_jitter.jpg

05:49 CL Telemetry
  • Bin 1
  • 990 Hz
  • 9.0 Mag
  • Recon 20170613_231742 (New FF, 10 iter)
  • 0.8"/2 /local/aomeas/adsec_calib/M2C/KL_v16/disturb/CmdDisturb_20170613_184455.fits
  • gains 1.23, 0.54, 0.3 opt gain
  • Gopt = 0.41
  • NCPA On
  • 061937, 061954, 062033, 062047, 062103

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170702_061937 ??? 9.2 323982 8 NaN 0.43 231742 1 400 990 0.5 0.2 0.1 3 130 ON 65.8 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error
20170702_061954 ??? 9.2 323982 7 NaN 0.39 231742 1 400 990 0.5 0.2 0.1 3 130 ON 65.1 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error
20170702_062033 ??? 9.2 323982 9 NaN 0.40 231742 1 400 990 0.5 0.2 0.1 3 130 ON 58.8 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error
20170702_062047 ??? 9.2 323982 6 NaN 0.40 231742 1 400 990 0.5 0.2 0.1 3 130 ON 65.0 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error
20170702_062103 ??? 9.2 323982 9 NaN 0.43 231742 1 400 990 0.5 0.2 0.1 3 130 ON 66.0 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error

  • 062103 PSF:
    062103_psf.jpg

  • 062103 Modal:
    062103_modal.jpg

TT LUT as a function of Loop Frequency

06:51 CL with not seeing

07:00 Generate Gopt signal files for many frequencies
  • print, sinusmode_generate(4, 10e-9, 30, 990, 'KL_v16', /EVEN)
  • /local/aomeas/adsec_calib/M2C/KL_v16/disturb/CmdDisturb_*
  • 990 20170702_074221
  • 625 20170702_085032
  • 500 20170702_085050
  • 400 20170702_085107
  • 300 20170702_085123
  • 200 20170702_085144
  • 105 20170702_085201

07:10 Dark files
  • 069 20 sec, 1 NDIT
  • 070 2.5 sec, 10 NDIT

07:57 990 Hz
X Y LUCI Comment
0.0 0.0 71
0.5 0.0 72
1.0 0.0 73
1.5 0.0 74
2.0 0.0 75
2.5 0.0 76
3.0 0.0 77
0.0 0.0 78
-0.5 0.0 79
-1.0 0.0 80
-1.5 0.0 81
-2.0 0.0 82
-2.5 0.0 83
-3.0 0.0 85
0.0 0.0 86
0.0 0.5 87
0.0 1.0 88
0.0 1.5 89
0.0 2.0 90
0.0 2.5 91 Gopt is now 0.7 compared to 0.42 before. Why? Loop seems more unstable as changing TT voltage
0.0 3.0 94
0.0 0.0 97 Gopt back to 0.44 ??
0.0 -0.5 98
0.0 -1.0 99
0.0 -1.5 100
0.0 -2.0 101 0.48
0.0 -2.5 102 0.52
0.0 -3.0 103 0.72 (alway get pupil misalignment in X direction of ~0.13 pix on each 0.5 TT Volt step)

07:57 600 Hz
  • gain 1.38, 0.6 0.2 manually
  • use 1.15, 0.6, 0.2

X Y LUCI Comment
0.0 0.0 112 gopt = 0.62
1.0 0.0 113 gopt = 0.61
2.0 0.0 114 gopt = 0.61
3.0 0.0 115 gopt = 0.63
0.0 0.0 116 gopt = 0.62
-1.0 0.0 117 gopt = 0.62
-2.0 0.0 118 gopt = 0.63 pupil delta y 0.17
-3.0 0.0 119 gopt = 0.61
0.0 0.0 120 gopt = 0.61
0.0 1.0 121 gopt = 0.61
0.0 2.0 122 gopt = 0.62 pupil delta x 0.16
0.0 3.0 123 gopt = 0.62
0.0 0.0 124 gopt = 0.63
0.0 -1.0 125 gopt = 0.63
0.0 -2.0 126 gopt = 0.64
0.0 -3.0 127 gopt = 0.62

09:51 400 Hz
  • bin 2
  • 13.1 mag
  • lamp 92
  • gains 0.85, 0.2, 0.2

X Y LUCI Comment
0.0 -3.0 128 gopt = 0.77
0.0 -1.5 129 gopt = 0.77
0.0 0.0 130 gopt = 0.77
0.0 1.5 131 gopt = 0.80
0.0 3.0 132 gopt = 0.7
0.0 0.0 133 gopt = 0.78
1.5 0.0 134 gopt = 0.78
3.0 0.0 135 gopt = 0.78
0.0 0.0 136 gopt = 0.72
-1.5 0.0 137 gopt = 0.7
-3.0 0.0 138 gopt = 0.78

10:28 200 Hz
  • bin 4
  • 12.8 mag
  • lamp 92
  • gains 2.67, 0.5, 0.55

X Y LUCI Comment
-3.0 0.0 139 gopt = 0.43
-1.5 0.0 140 gopt = 0.78
0.0 0.0 141 gopt = 0.78
1.5 0.0 142 gopt = 0.78
3.0 0.0 143 gopt = 0.78
0.0 0.0 144 gopt = 0.78
0.0 1.5 145 gopt = 0.78
0.0 3.0 146 gopt = 0.78
0.0 0.0 147 gopt = 0.78
0.0 -1.5 148 gopt = 0.78
0.0 -3.0 149 gopt = 0.78

11:04 105 Hz
  • bin 4
  • 14.1 mag
  • lamp 84
  • gains 2.0, 0.3, 0.4

X Y LUCI
0.0 -3.0 152
0.0 -1.5 153
0.0 0.0 154
0.0 1.5 155
0.0 3.0 156
0.0 0.0 157
1.5 0.0 158
3.0 0.0 160
-1.5 0.0 161
-3.0 0.0 162
0.0 0.0 163

11:27 Darks
  • 2.5s 3NDIT 164

-- %USERSIG{DougMiller - 2017-07-02}%
I Attachment Action Size Date Who Comment
053938_jitter.jpgjpg 053938_jitter.jpg manage 123 K 02 Jul 2017 - 06:27 DougMiller 053938 Plots
053938_modal.jpgjpg 053938_modal.jpg manage 101 K 02 Jul 2017 - 06:26 DougMiller 053938 Plots
053938_psf.jpgjpg 053938_psf.jpg manage 131 K 02 Jul 2017 - 06:24 DougMiller 053938
062103_modal.jpgjpg 062103_modal.jpg manage 61 K 19 Jul 2017 - 17:33 DougMiller 062103 Modal
062103_psf.jpgjpg 062103_psf.jpg manage 132 K 02 Jul 2017 - 06:32 DougMiller 062103 PSF
Topic revision: r5 - 19 Jul 2017, DougMiller