New FF, New DX Reconstructor Performance Testing with ARGOS CalUnit

05:00 Start up System
  • Set DX Flat
  • Power on DX WUnit
  • Deploy DX ARGOS CalUnit
  • Turn on light source

05:30 No light to be seen
  • Spiral search
  • Oops, realize the light source shutter was closed
  • Open shutter
  • Immediately see light

06:40 Get light centered
  • Add z7, z8 to center central obscuration to center of out of focus image
  • Add z6 = -2 to remove astigmatism (via AdSec Control GUI)

07:11 Closed Loop
  • 990 Hz
  • bin 1
  • Recon 20170613_231742 (New FF, 10 iter)
  • no seeing
  • No LUCI
  • 071105
  • flat 20170701_400_1
  • reload flat with 643 modes. Looks Great!

07:31
  • 990 Hz
  • bin 1
  • Recon 20170613_231742 (New FF, 10 iter)
  • no seeing
  • LUCI images: FeII
  • No NCPA
  • Opt Loop data
    • 073441, 073543, 073605
  • 073441 PSF, No Seeing, FeII:
    073441_psf.jpg
  • 073441 Jitter Plot, No Seeing, FeII:
    073441_jitter.jpg

07:55
  • 990 Hz
  • Bin 1
  • Recon 20170613_231742 (New FF, 10 iter)
  • 0.8"/2 /local/aomeas/adsec_calib/M2C/KL_v16/disturb/CmdDisturb_20170613_184455.fits
  • gains 1.23, 0.35, 0.29
  • Gopt = 0.5
  • NCPA On
  • Best focus
    • 55.4 081535
    • 55.5 081610
    • 55.6 081636
    • 55.7 081712
    • 55.8 081744
    • 55.9 081816
    • 56.0 081837

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170701_081535 ??? 9.4 323981 8 NaN 0.42 231742 1 400 990 0.6 0.2 0.1 3 108 ON 63.6 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Background correction failed
20170701_081610 ??? 9.4 323981 8 NaN 0.42 231742 1 400 990 0.6 0.2 0.1 3 107 ON 66.5 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170701_081636 ??? 9.4 323981 8 NaN 0.43 231742 1 400 990 0.6 0.2 0.1 3 106 ON 66.7 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170701_081712 ??? 9.4 323981 8 NaN 0.43 231742 1 400 990 0.6 0.2 0.1 3 107 ON 66.1 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Background correction failed
20170701_081744 ??? 9.4 323981 7 NaN 0.42 231742 1 400 990 0.6 0.2 0.1 3 107 ON 65.3 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170701_081816 ??? 9.4 323981 8 NaN 0.42 231742 1 400 990 0.6 0.2 0.1 3 107 ON 64.8 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Background correction failed
20170701_081837 ??? 9.4 323981 8 NaN 0.43 231742 1 400 990 0.6 0.2 0.1 3 106 ON 62.1 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error

08:24 Best focus at 55.6
  • Edited /home/aoeng/aoroot/calib/wfs/current/setups/LUCIFER_ACE-AO and RETROREF_ACE-AO
  • Need to put this into confcalib

08:28 Opt Loop Data at 0.8"
  • Gains 1.2, 0.35, 0.3
  • Gopt = 0.5
  • NCPA On (new LUT)
  • 082903, 083006, 083021, 083042, 083121

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170701_082903 ??? 9.4 323981 8 NaN 0.43 231742 1 400 990 0.6 0.2 0.1 3 110 ON 65.6 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Warning: Selected luci dark +1h old!
20170701_083006 ??? 9.4 323981 8 NaN 0.41 231742 1 400 990 0.6 0.2 0.1 3 110 ON 67.0 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Warning: Selected luci dark +1h old!
20170701_083021 ??? 9.4 323981 9 NaN 0.42 231742 1 400 990 0.6 0.2 0.1 3 110 ON 68.4 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Warning: Selected luci dark +1h old!
20170701_083042 ??? 9.4 323981 8 NaN 0.42 231742 1 400 990 0.6 0.2 0.1 3 109 ON 66.8 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Background correction failed - Warning: Selected luci dark +1h old!
20170701_083121 ??? 9.4 323981 9 NaN 0.42 231742 1 400 990 0.6 0.2 0.1 3 110 ON 66.5 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Warning: Selected luci dark +1h old!

  • 083021 Plots:
    083021_modal.jpg
  • 083021 Plots:
    083021_psf.jpg

08:39 Need to create new turbulence files that are consistent with new FF Matrix (?)
  • email from Fernando on Feb 12, 2016
  • not sure we have the correct directory structure on the new AdSec machines

09:37
  • 990 Hz
  • Bin 1
  • Recon 20170613_231742 (New FF, 10 iter)
  • 1.2"/2 /local/aomeas/adsec_calib/M2C/KL_v16/disturb/CmdDisturb_20170613_190727.fits
  • gains 1.2, 0.4, 0.3
  • Gopt = 0.42
  • NCPA On
  • 095414, 095437, 095452, 095522, 095540

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170701_095414 ??? 9.4 323981 9 NaN 0.63 231742 1 400 990 0.5 0.2 0.1 3 105 ON 62.2 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170701_095437 ??? 9.4 323981 7 NaN 0.63 231742 1 400 990 0.5 0.2 0.1 3 105 ON 59.9 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Background correction failed
20170701_095452 ??? 9.4 323981 6 NaN 0.62 231742 1 400 990 0.5 0.2 0.1 3 106 ON 60.8 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170701_095522 ??? 9.4 323981 7 NaN 0.62 231742 1 400 990 0.5 0.2 0.1 3 106 ON 62.2 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Background correction failed
20170701_095540 ??? 9.4 323981 8 NaN 0.62 231742 1 400 990 0.5 0.2 0.1 3 106 ON 60.4 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error

  • 095522 PSF:
    095522_psf.jpg

10:09 Switch to OH1060/Z filter
  • Same as above
  • NCPA On
  • 100949, 101011, 101027, 101042, 101057

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170701_100949 ??? 9.4 323981 9 NaN 0.62 231742 1 400 990 0.5 0.2 0.1 3 104 ON 0.0 OH_1060 z 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Center of PSF estimation error
20170701_101011 ??? 9.4 323981 10 NaN 0.62 231742 1 400 990 0.5 0.2 0.1 3 103 ON 31.1 OH_1060 z 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170701_101027 ??? 9.4 323981 9 NaN 0.62 231742 1 400 990 0.5 0.2 0.1 3 103 ON 0.0 OH_1060 z 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Center of PSF estimation error
20170701_101042 ??? 9.4 323981 9 NaN 0.62 231742 1 400 990 0.5 0.2 0.1 3 104 ON 0.0 OH_1060 z 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Center of PSF estimation error
20170701_101057 ??? 9.4 323981 8 NaN 0.62 231742 1 400 990 0.5 0.2 0.1 3 103 ON 30.7 OH_1060 z 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error

  • 101011 PSF:
    101011_psf.jpg

10:21 Back to FeII/Clear

10:31 Bin 2
  • 9.0 mag
  • 990 Hz
  • Bin 2
  • Recon 20170614_222920 (New FF, 10 iter)
  • 1.2"/2 /local/aomeas/adsec_calib/M2C/KL_v16/disturb/CmdDisturb_20170613_190727.fits
  • gains 1.55, 0.5, 0.4
  • NCPA Off
  • 104802, 104823, 104838, 104853, 104908

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170701_104802 ??? 9.2 323981 9 NaN 0.69 222920 2 153 991 0.6 0.2 0.1 3 471 ON 43.3 FeII clear 157 20 ONSKY NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error
20170701_104823 ??? 9.2 323981 9 NaN 0.68 222920 2 153 991 0.6 0.2 0.1 3 471 ON 41.7 FeII clear 157 20 ONSKY NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error - Background correction failed
20170701_104838 ??? 9.2 323981 9 NaN 0.68 222920 2 153 991 0.6 0.2 0.1 3 471 ON 42.4 FeII clear 157 20 ONSKY NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error - Background correction failed
20170701_104853 ??? 9.2 323981 9 NaN 0.70 222920 2 153 991 0.6 0.2 0.1 3 471 ON 43.0 FeII clear 157 20 ONSKY NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error
20170701_104908 ??? 9.2 323981 9 NaN 0.73 222920 2 153 991 0.6 0.2 0.1 3 471 ON 39.2 FeII clear 157 20 ONSKY NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error

  • 104853 Plots:
    104853_modal.jpg
  • 104853 Plots:
    104853_psf.jpg

10:49 Bin 2
  • Same a above
  • Gopt = 0.5
  • NCPA On
  • 105012, 105027, 105042, 105057, 105112

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170701_105012 ??? 9.2 323981 10 NaN 0.69 222920 2 153 991 0.6 0.2 0.1 3 471 ON 55.0 FeII clear 157 20 ONSKY NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error - Background correction failed
20170701_105027 ??? 9.2 323981 10 NaN 0.68 222920 2 153 991 0.6 0.2 0.1 3 471 ON 55.1 FeII clear 157 20 ONSKY NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error - Background correction failed
20170701_105042 ??? 9.2 323981 9 NaN 0.72 222920 2 153 991 0.6 0.2 0.1 3 471 ON 54.4 FeII clear 157 20 ONSKY NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error
20170701_105057 ??? 9.2 323981 9 NaN 0.72 222920 2 153 991 0.6 0.2 0.1 3 472 ON 56.3 FeII clear 157 20 ONSKY NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error
20170701_105112 ??? 9.2 323981 9 NaN 0.71 222920 2 153 991 0.6 0.2 0.1 3 471 ON 54.7 FeII clear 157 20 ONSKY NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error - Background correction failed

  • 105057 Plots:
    105057_psf.jpg

11:09 Bin 2
  • 11.5 mag (lamp at 103)
  • same as above
  • gains 1.92, 0.74, 0.21
  • No NCPA
  • 111202, 111222, 111237, 111254, 111309

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170701_111202 ??? 11.7 323981 8 NaN 0.66 222920 2 153 991 1.9 0.7 0.2 3 47 ON 0.0 FeII clear 157 20 ONSKY NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error - Center of PSF estimation error
20170701_111222 ??? 11.7 323981 8 NaN 0.64 222920 2 153 991 1.9 0.7 0.2 3 48 ON 0.0 FeII clear 157 20 ONSKY NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error - Center of PSF estimation error
20170701_111237 ??? 11.7 323981 8 NaN 0.65 222920 2 153 991 1.9 0.7 0.2 3 47 ON 0.0 FeII clear 157 20 ONSKY NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error - Center of PSF estimation error
20170701_111254 ??? 11.7 323981 9 NaN 0.64 222920 2 153 991 1.9 0.7 0.2 3 48 ON 0.0 FeII clear 157 20 ONSKY NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error - Center of PSF estimation error
20170701_111309 ??? 11.7 323981 8 NaN 0.64 222920 2 153 991 1.9 0.7 0.2 3 48 ON 0.0 FeII clear 157 20 ONSKY NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error - Center of PSF estimation error

  • 111237 PSF:
    111237_psf.jpg

11:14 Bin 2
  • same as above
  • NCPA On
  • with above gains there was some T/T oscillation
  • gain 1.6, 0.7, 0.3
  • no oscillations
  • NCPA On
  • 111921, 111943, 112005, 112028, 112050

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170701_111921 ??? 11.7 323981 9 NaN 0.90 222920 2 153 991 0.6 0.2 0.1 3 47 ON 0.0 FeII clear 157 20 ONSKY NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error - Center of PSF estimation error
20170701_111943 ??? 11.7 323981 8 NaN 0.92 222920 2 153 991 0.6 0.2 0.1 3 47 ON 0.0 FeII clear 157 20 ONSKY NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error - Center of PSF estimation error
20170701_112005 ??? 11.7 323981 8 NaN 0.93 222920 2 153 991 0.6 0.2 0.1 3 47 ON 0.0 FeII clear 157 20 ONSKY NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error - Center of PSF estimation error
20170701_112028 ??? 11.7 323981 8 NaN 0.96 222920 2 153 991 0.6 0.2 0.1 3 48 ON 0.0 FeII clear 157 20 ONSKY NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error - Center of PSF estimation error
20170701_112050 ??? 11.7 323981 8 NaN 0.96 222920 2 153 991 0.6 0.2 0.1 3 47 ON 0.0 FeII clear 157 20 ONSKY NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error - Center of PSF estimation error

  • 112005 PSF:
    112005_psf.jpg

11:34 Bin 3
  • 14.0 mag (lamp at 85)
  • 500 Hz
  • bin 3
  • Rec 20170614_225826
  • gain 1.8, 0.75, 0.65 (opt gain had T/T at 0.72. Set it manually)
  • NCPA Off
  • 114315, 114342, 114424, 114439, 114504

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170701_114315 ??? 14.2 323981 10 NaN 0.59 225826 3 66 500 1.8 0.8 -1.0 6 23 ON 0.0 FeII clear 157 20 ONSKY NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error - Center of PSF estimation error
20170701_114342 ??? 14.2 323981 11 NaN 0.60 225826 3 66 500 1.8 0.8 -1.0 6 22 ON 0.0 FeII clear 157 20 ONSKY NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error - Center of PSF estimation error
20170701_114424 ??? 14.1 323981 9 NaN 0.59 225826 3 66 500 1.8 0.8 -1.0 6 25 ON 0.0 FeII clear 157 20 ONSKY NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error - Center of PSF estimation error
20170701_114439 ??? 14.1 323981 10 NaN 0.59 225826 3 66 500 1.8 0.8 -1.0 6 25 ON 0.0 FeII clear 157 20 ONSKY NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error - Center of PSF estimation error
20170701_114504 ??? 14.1 323981 8 NaN 0.59 225826 3 66 500 1.8 0.8 -1.0 6 24 ON 0.0 FeII clear 157 20 ONSKY NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error - Center of PSF estimation error

  • 115019 PSF:
    114424_psf.jpg

11:49 Bin 3
  • same as above
  • NCPA On (manually set Z5,6 to -30, -10)
  • 114917, 115001, 115019, 115038, 115053

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170701_114917 ??? 14.1 323981 9 NaN 0.70 225826 3 66 500 1.8 0.8 -1.0 6 24 ON 0.0 FeII clear 157 20 ONSKY NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error - Center of PSF estimation error
20170701_115001 ??? 14.2 323981 9 NaN 0.61 225826 3 66 500 1.8 0.8 -1.0 6 23 ON 0.0 FeII clear 157 20 ONSKY NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error - Center of PSF estimation error
20170701_115019 ??? 14.2 323981 9 NaN 0.62 225826 3 66 500 1.8 0.8 -1.0 6 23 ON 0.0 FeII clear 157 20 ONSKY NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error - Center of PSF estimation error
20170701_115038 ??? 14.2 323981 9 NaN 0.62 225826 3 66 500 1.8 0.8 -1.0 6 23 ON 0.0 FeII clear 157 20 ONSKY NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error - Center of PSF estimation error
20170701_115053 ??? 14.2 323981 9 NaN 0.63 225826 3 66 500 1.8 0.8 -1.0 6 22 ON 0.0 FeII clear 157 20 ONSKY NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - WFSGlobalTimeout error - Center of PSF estimation error

  • 115019 PSF:
    115019_psf.jpg

11:57 Bin 4
  • 15.4 mag (78)
  • 200 Hz
  • bin 4
  • Rec 20170614_232600
  • gain 1.4, 0.3, 0.15
  • No NCPA
  • 121805, 121830, 121853, 121916, 121940

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170701_121805 ??? 15.6 323981 9 NaN 0.12 232600 4 36 100 1.4 0.3 -1.0 6 53 ON 0.0 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Center of PSF estimation error
20170701_121830 ??? 15.6 323981 8 NaN 0.11 232600 4 36 100 1.4 0.3 -1.0 6 53 ON 0.0 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Center of PSF estimation error
20170701_121853 ??? 15.6 323981 8 NaN 0.11 232600 4 36 100 1.4 0.3 -1.0 6 53 ON 0.0 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Center of PSF estimation error
20170701_121916 ??? 15.6 323981 10 NaN 0.11 232600 4 36 100 1.4 0.3 -1.0 6 53 ON 0.0 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Center of PSF estimation error
20170701_121940 ??? 15.6 323981 9 NaN 0.11 232600 4 36 100 1.4 0.3 -1.0 6 53 ON 0.0 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Center of PSF estimation error

  • 121853 PSF:
    121853_psf.jpg

12:19 Bin 4
  • Same as above
  • NCPA On; try to manually apply Z5
  • can not apply ncpa because the shell takes a shape such that there is not light on some parts of the shell so no control

12:30 Stop data collection.

-- %USERSIG{DougMiller - 2017-07-01}%

I Attachment Action Size Date Who Comment
073441_jitter.jpgjpg 073441_jitter.jpg manage 56 K 01 Jul 2017 - 07:43 DougMiller 073441 Jitter Plot, No Seeing, FeII
073441_psf.jpgjpg 073441_psf.jpg manage 144 K 01 Jul 2017 - 07:47 DougMiller 073441 PSF, No Seeing, FeII
083021_modal.jpgjpg 083021_modal.jpg manage 84 K 01 Jul 2017 - 08:38 DougMiller 083021 Plots
083021_psf.jpgjpg 083021_psf.jpg manage 133 K 01 Jul 2017 - 08:38 DougMiller 083021 Plots
095522_psf.jpgjpg 095522_psf.jpg manage 129 K 01 Jul 2017 - 10:12 DougMiller 095522 PSF
101011_psf.jpgjpg 101011_psf.jpg manage 164 K 01 Jul 2017 - 10:20 DougMiller 101011 PSF
104853_modal.jpgjpg 104853_modal.jpg manage 86 K 01 Jul 2017 - 11:06 DougMiller 104853 Plots
104853_psf.jpgjpg 104853_psf.jpg manage 132 K 01 Jul 2017 - 11:06 DougMiller 104853 Plots
105057_psf.jpgjpg 105057_psf.jpg manage 132 K 01 Jul 2017 - 11:06 DougMiller 104853 Plots
111237_psf.jpgjpg 111237_psf.jpg manage 100 K 01 Jul 2017 - 11:28 DougMiller 112005 PSF
112005_psf.jpgjpg 112005_psf.jpg manage 100 K 01 Jul 2017 - 11:28 DougMiller 112005 PSF
114424_psf.jpgjpg 114424_psf.jpg manage 112 K 01 Jul 2017 - 11:56 DougMiller 115019 PSF
115019_psf.jpgjpg 115019_psf.jpg manage 114 K 01 Jul 2017 - 11:56 DougMiller 115019 PSF
121853_psf.jpgjpg 121853_psf.jpg manage 115 K 01 Jul 2017 - 12:28 DougMiller 121853 PSF