DX Reconstructor Testing

04:45 Get Started.
  • Power on DX WFS

05:10 Cleanup board setup directory
  • Have setups from 6 years ago
  • mkdir /home/aoeng/aoroot/wfsW2/setups/directory_of_old
  • cp /home/aoeng/aoroot/wfsW2/setups/* /home/aoeng/aoroot/wfsW2/setups/directory_of_old
  • Will need to make this modification to confcalib directory

06:30 tried data_5 FF matrix
  • same trouble with 400 mode skip frame

07:05 Find a large amount of astigmatism in flats (i.e. 20170629_400_7.sav)
  • z6 = 3.2 removes most of it

07:15 Go back to data_10 FF matrix
  • Same problem. HO gain turned up and get checker board pattern

08:00 Tried putting back into use the 4 actuators that I had removed that were causing high force on flat (had 664 yesterday on these flats). They were
  • 340
  • 453
  • 484
  • 452
  • all long the bottom edge
  • Get 200 modes

08:13 Have now removed 340, 453, 452
  • removed 484
  • 20170630_400_7.sav
  • 332 modes

08:55 CL 400 modes
  • gain 0.20, 0.10, 0.05
  • flat 20170630_400_1
  • gain 0.35, 0.20, 0.15
  • flat 20170630_400_2
  • load _2 get 643 modes

09:05 HBS on
  • no seeing
  • rec 20170613_175001
  • gains 0.2, 0.15, 0.05 Manual
  • 091339
  • gains 0.45, 0.15, 0.05 manual
  • 091518

09:17 HBS on
  • 0.8" seeing
  • rec 20170613_175001
  • gains 0.65, 0.30, 0.05 manual
  • top edge rolls with more than 0.05 HO2
  • 092012
  • gains 0.68, 0.39, 0.19 (opt gain)
  • 092158

09:23 HBS off
  • 0.8" seeing
  • same Rec
  • gains 0.58, 0.19, 0.10 manual
  • 092317
  • Opt gain stop with skip frame

09:43 HBS off
  • rotated retrocube by 180 to 23.994, stage -1.9
  • Same rec 175001
  • 0.8" seeing
  • gains 0.6, 0.31, 0.25 (opt gain)
  • 094341
  • flat 20170630_400_3
  • apply 643 modes

09:50 HBS off
  • 0.8" seeing
  • rec 201613_231742
  • gain 0.65, 0.34, 0.20 (opt gain)
  • 095147

09:53 HBS off
  • no seeing
  • rec 231742
  • gain 0.42, 0.21, 0.16 (opt Gain)
  • 095353, 095548

10:00 Back to original RetroCube position of 203.472
  • still bad illumination
  • moved cube stage, but not better

10:18 Back to 24.048 on RetroCube rotation
  • no seeing
  • gain 0.42, 0.2, 0.1 (opt gain)
  • 101814

10:34 HBS Off
  • 0.8" seeing
  • gain 0.5, 0.2, 0.1 manual
  • 103442

10:35 Barry start up LUCI2

10:58 20 Darks
  • 105831

11:07
  • HBS off
  • rec 231742
  • 0.8" seeing
  • No Gopt or NCPA
  • Luci images
  • 110735

11:14
  • HBS on
  • rec 231742
  • 0.8" seeing
  • No Gopt or NCPA
  • Luci images
  • 111430

-- %USERSIG{DougMiller - 2017-06-30}%
  • 110735:
    110735_modal.jpg

  • 110735:
    110735_psf.jpg
Topic revision: r4 - 07 Aug 2017, DougMiller
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.