Results of Measurements of June 12 - June 14

June 12

LUCI2 Rotator at 29 degrees.

New FF Matrix (5 iter), New Recon (4 iter)

1.5" Seeing, NCPA On
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170612_221513 ??? 7.2 323986 16 NaN -1.00 201442 1 400 990 0.4 0.3 0.2 3 767 ON 25.8 P_beta clear 157 20 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - 1.5" Disturb, NCPA Correction - 1/2 Amplitude due to double pass
20170612_221532 ??? 7.3 323986 13 NaN -1.00 201442 1 400 990 0.4 0.3 0.2 3 758 ON 24.4 P_beta clear 157 20 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - 1.5" Disturb, NCPA Correction - 1/2 Amplitude due to double pass
20170612_221604 ??? 7.3 323986 17 NaN -1.00 201442 1 400 990 0.4 0.3 0.2 3 753 ON 27.1 P_beta clear 157 20 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - 1.5" Disturb, NCPA Correction - 1/2 Amplitude due to double pass
20170612_221624 ??? 7.3 323986 14 NaN -1.00 201442 1 400 990 0.4 0.3 0.2 3 747 ON 26.8 P_beta clear 157 20 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - 1.5" Disturb, NCPA Correction - 1/2 Amplitude due to double pass

0.8" Seeing, NCPA Off
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170612_222445 ??? 7.3 323986 17 NaN -1.00 201442 1 400 990 0.3 0.2 -1.0 3 759 ON 13.6 P_beta clear 157 20 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - 0.8" Disturb, No NCPA Correction - No GOPT
20170612_222518 ??? 7.3 323986 16 NaN -1.00 201442 1 400 990 0.3 0.2 -1.0 3 748 ON 13.4 P_beta clear 157 20 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - 0.8" Disturb, No NCPA Correction - No GOPT
20170612_222541 ??? 7.3 323986 15 NaN -1.00 201442 1 400 990 0.3 0.2 -1.0 3 748 ON 13.5 P_beta clear 157 20 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - 0.8" Disturb, No NCPA Correction - No GOPT
20170612_222609 ??? 7.3 323986 18 NaN -1.00 201442 1 400 990 0.3 0.2 -1.0 3 727 ON 13.0 P_beta clear 157 20 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - 0.8" Disturb, No NCPA Correction - No GOPT
20170612_222626 ??? 7.4 323986 16 NaN -1.00 201442 1 400 990 0.3 0.2 -1.0 3 668 ON 14.3 P_beta clear 157 20 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - 0.8" Disturb, No NCPA Correction - No GOPT

0.8" Seeing, NCPA On
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170612_223215 ??? 7.3 323986 8 NaN -1.00 201442 1 400 990 0.4 0.2 0.2 3 762 ON 33.7 P_beta clear 157 20 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - 0.8" Disturb, NCPA Correction - 1/2 Amplitude due to double pass
20170612_223231 ??? 7.3 323986 13 NaN -1.00 201442 1 400 990 0.4 0.2 0.2 3 764 ON 32.8 P_beta clear 157 20 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - 0.8" Disturb, NCPA Correction - 1/2 Amplitude due to double pass
20170612_223247 ??? 7.3 323986 13 NaN -1.00 201442 1 400 990 0.4 0.2 0.2 3 760 ON 32.2 P_beta clear 157 20 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - 0.8" Disturb, NCPA Correction - 1/2 Amplitude due to double pass
20170612_223307 ??? 7.2 323986 9 NaN -1.00 201442 1 400 990 0.4 0.2 0.2 3 793 ON 34.6 P_beta clear 157 20 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Background correction failed - 0.8" Disturb, NCPA Correction - 1/2 Amplitude due to double pass

June 13

LUCI Rotator at 210 degrees

New FF matrices (5 iter), New Recon (48 iter)

0.8" Seeing, NCPA Off
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170613_184834 ??? 6.9 323986 8 NaN -1.00 175001 1 400 990 0.6 0.4 0.3 3 1047 ON 33.9 P_beta clear 157 20 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Pupils not on target - 0.8" Disturb, No GOPT, No NCPA - 5 Iteration, New FF Matrix
20170613_184852 ??? 6.9 323986 7 NaN -1.00 175001 1 400 990 0.6 0.4 0.3 3 1060 ON 36.0 P_beta clear 157 20 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - 0.8" Disturb, No GOPT, No NCPA - 5 Iteration, New FF Matrix
20170613_184909 ??? 6.9 323986 6 NaN -1.00 175001 1 400 990 0.6 0.4 0.3 3 1064 ON 33.6 P_beta clear 157 20 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error- 0.8" Disturb, No GOPT, No NCPA - 5 Iteration, New FF Matrix
20170613_185019 ??? 6.9 323986 6 NaN -1.00 175001 1 400 990 0.6 0.4 0.3 3 1051 ON 34.5 P_beta clear 157 20 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Pupils not on target - Background correction failed - 0.8" Disturb, No GOPT, No NCPA - 5 Iteration, New FF Matrix

0.8" Seeing, NCPA On
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170613_185322 ??? 6.9 323986 7 NaN -1.00 175001 1 400 990 0.6 0.4 0.3 3 1038 ON 37.7 P_beta clear 157 20 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Pupils not on target - 0.8" Disturb, NCPA on, 1/2 Amplitude - 5 Iteration, New FF Matrix
20170613_185517 ??? 6.9 323986 7 NaN -1.00 175001 1 400 990 0.6 0.4 0.3 3 1034 ON 38.2 P_beta clear 157 20 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Pupils not on target - 0.8" Disturb, NCPA on, 1/2 Amplitude - 5 Iteration, New FF Matrix
20170613_185535 ??? 6.9 323986 4 NaN -1.00 175001 1 400 990 0.6 0.4 0.3 3 1030 ON 37.3 P_beta clear 157 20 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Pupils not on target - 0.8" Disturb, NCPA on, 1/2 Amplitude - 5 Iteration, New FF Matrix
20170613_185552 ??? 6.9 323986 3 NaN -1.00 175001 1 400 990 0.6 0.4 0.3 3 1029 ON 33.3 P_beta clear 157 20 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Pupils not on target - 0.8" Disturb, NCPA on, 1/2 Amplitude - 5 Iteration, New FF Matrix

1.0" Seeing, NCPA Off
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170613_190135 ??? 6.9 323986 9 NaN -1.00 175001 1 400 990 0.6 0.4 0.3 3 1054 ON 23.8 P_beta clear 157 20 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Warning: Selected luci dark +1h old! - 1.0" Disturb, NCPA Off, GOPT Off - 5 Iteration, New FF Matrix
20170613_190153 ??? 6.9 323986 9 NaN -1.00 175001 1 400 990 0.6 0.4 0.3 3 1055 ON 32.4 P_beta clear 157 20 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Pupils not on target - Warning: Selected luci dark +1h old! - 1.0" Disturb, NCPA Off, GOPT Off - 5 Iteration, New FF Matrix
20170613_190215 ??? 6.9 323986 7 NaN -1.00 175001 1 400 990 0.6 0.4 0.3 3 1048 ON 32.0 P_beta clear 157 20 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Warning: Selected luci dark +1h old! - 1.0" Disturb, NCPA Off, GOPT Off - 5 Iteration, New FF Matrix
20170613_190240 ??? 6.9 323986 7 NaN -1.00 175001 1 400 990 0.6 0.4 0.3 3 1065 ON 34.3 P_beta clear 157 20 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Background correction failed - Warning: Selected luci dark +1h old! - 1.0" Disturb, NCPA Off, GOPT Off - 5 Iteration, New FF Matrix

1.0" Seeing, NCPA On
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170613_190347 ??? 6.8 323986 5 NaN -1.00 175001 1 400 990 0.6 0.3 0.3 3 1105 ON 37.4 P_beta clear 157 20 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Pupils not on target - Warning: Selected luci dark +1h old! - 1.0" Disturb, NCPA On, 1/2 Amplitude - 5 Iteration, New FF Matrix
20170613_190407 ??? 6.8 323986 3 NaN -1.00 175001 1 400 990 0.6 0.3 0.3 3 1107 ON 34.5 P_beta clear 157 20 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Pupils not on target - Warning: Selected luci dark +1h old! - 1.0" Disturb, NCPA On, 1/2 Amplitude - 5 Iteration, New FF Matrix
20170613_190432 ??? 6.9 323986 4 NaN -1.00 175001 1 400 990 0.6 0.3 0.3 3 1104 ON 33.6 P_beta clear 157 20 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Warning: Selected luci dark +1h old! - 1.0" Disturb, NCPA On, 1/2 Amplitude - 5 Iteration, New FF Matrix
20170613_190454 ??? 6.8 323986 5 NaN -1.00 175001 1 400 990 0.6 0.3 0.3 3 1108 ON 34.8 P_beta clear 157 20 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - long stop of 51 frames at frame 2853 - Warning: Selected luci dark +1h old! - 1.0" Disturb, NCPA On, 1/2 Amplitude - 5 Iteration, New FF Matrix

1.2" Seeing, NCPA Off
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170613_190910 ??? 6.9 323986 2 NaN -1.00 175001 1 400 990 0.8 0.5 0.4 3 1103 ON 27.8 P_beta clear 157 20 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - 1.2" Disturb, No GOPT, No NCPA - 5 Iteration, New FF Matrix
20170613_190928 ??? 6.9 323986 3 NaN -1.00 175001 1 400 990 0.8 0.5 0.4 3 1092 ON 27.2 P_beta clear 157 20 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - long stop of 83 frames at frame 3509 - 1.2" Disturb, No GOPT, No NCPA - 5 Iteration, New FF Matrix
20170613_191011 ??? 6.9 323986 3 NaN -1.00 175001 1 400 990 0.8 0.5 0.4 3 1070 ON 28.6 P_beta clear 157 20 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - 1.2" Disturb, No GOPT, No NCPA - 5 Iteration, New FF Matrix
20170613_191031 ??? 6.9 323986 7 NaN -1.00 175001 1 400 990 0.8 0.5 0.4 3 1059 ON 31.5 P_beta clear 157 20 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - 1.2" Disturb, No GOPT, No NCPA - 5 Iteration, New FF Matrix

New FF matrices (10 iter), New Recon (4 iter)

0.8" Seeing, NCPA Off, New 10 iteration FF Matrix
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170613_212305 ??? 6.8 323987 5 NaN -1.00 211604 1 400 990 0.6 0.4 0.3 3 1118 ON 33.6 P_beta clear 157 20 ON NO - FLTimeout error - PendingCounter error - TimeStamp error - WFSGlobalTimeout error - SR may be in error - Warning: Selected luci dark +1h old! - 0.8" Disturb, No GOPT, No NCPA - 10 Iteration, New FF Matrix
20170613_212416 ??? 6.8 323987 5 NaN -1.00 211604 1 400 990 0.6 0.4 0.3 3 1109 ON 32.1 P_beta clear 157 20 ON NO - FLTimeout error - PendingCounter error - TimeStamp error - WFSGlobalTimeout error - SR may be in error - Warning: Selected luci dark +1h old! - 0.8" Disturb, No GOPT, No NCPA - 10 Iteration, New FF Matrix
20170613_212437 ??? 6.9 323987 8 NaN -1.00 211604 1 400 990 0.6 0.4 0.3 3 1091 ON 30.7 P_beta clear 157 20 ON NO - FLTimeout error - PendingCounter error - TimeStamp error - WFSGlobalTimeout error - SR may be in error - Warning: Selected luci dark +1h old! - 0.8" Disturb, No GOPT, No NCPA - 10 Iteration, New FF Matrix
20170613_212459 ??? 6.9 323987 6 NaN -1.00 211604 1 400 990 0.6 0.4 0.3 3 1081 ON 35.1 P_beta clear 157 20 ON NO - FLTimeout error - PendingCounter error - TimeStamp error - WFSGlobalTimeout error - SR may be in error - Warning: Selected luci dark +1h old! - 0.8" Disturb, No GOPT, No NCPA - 10 Iteration, New FF Matrix

0.8" Seeing, NCPA On, New 10 iteration FF Matrix
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170613_212919 ??? 6.9 323987 8 NaN -1.00 211604 1 400 990 0.5 0.3 0.2 3 1046 ON 31.7 P_beta clear 157 20 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Pupils not on target - SR may be in error - Warning: Selected luci dark +1h old! - 0.8" Disturb, NCPA - 10 Iteration, New FF Matrix
20170613_212938 ??? 6.9 323987 7 NaN -1.00 211604 1 400 990 0.5 0.3 0.2 3 1044 ON 33.5 P_beta clear 157 20 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Pupils not on target - SR may be in error - Warning: Selected luci dark +1h old! - 0.8" Disturb, NCPA - 10 Iteration, New FF Matrix
20170613_213004 ??? 6.9 323987 5 NaN -1.00 211604 1 400 990 0.5 0.3 0.2 3 1043 ON 37.7 P_beta clear 157 20 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Pupils not on target - SR may be in error - Warning: Selected luci dark +1h old! - 0.8" Disturb, NCPA - 10 Iteration, New FF Matrix
20170613_213027 ??? 6.9 323987 5 NaN -1.00 211604 1 400 990 0.5 0.3 0.2 3 1038 ON 32.8 P_beta clear 157 20 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Pupils not on target - SR may be in error - Warning: Selected luci dark +1h old! - 0.8" Disturb, NCPA - 10 Iteration, New FF Matrix

1.0" Seeing, NCPA Off, New 10 iteration FF Matrix
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170613_213223 ??? 6.9 323987 6 NaN -1.00 211604 1 400 990 0.6 0.4 0.3 3 1039 ON 30.7 P_beta clear 157 20 OFF NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - SR may be in error - Warning: Selected luci dark +1h old! - 1.0" Disturb, No GOPT, No NCPA - 10 Iteration, New FF Matrix
20170613_213240 ??? 6.9 323987 5 NaN -1.00 211604 1 400 990 0.6 0.4 0.3 3 1048 ON 32.2 P_beta clear 157 20 OFF NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - SR may be in error - Warning: Selected luci dark +1h old! - 1.0" Disturb, No GOPT, No NCPA - 10 Iteration, New FF Matrix
20170613_213301 ??? 6.9 323987 8 NaN -1.00 211604 1 400 990 0.6 0.4 0.3 3 1041 ON 30.8 P_beta clear 157 20 OFF NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - SR may be in error - Warning: Selected luci dark +1h old! - 1.0" Disturb, No GOPT, No NCPA - 10 Iteration, New FF Matrix
20170613_213320 ??? 6.9 323987 5 NaN -1.00 211604 1 400 990 0.6 0.4 0.3 3 1045 ON 32.0 P_beta clear 157 20 OFF NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - SR may be in error - Warning: Selected luci dark +1h old! - 1.0" Disturb, No GOPT, No NCPA - 10 Iteration, New FF Matrix

1.0" Seeing, NCPA On, New 10 iteration FF Matrix
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170613_213358 ??? 6.9 323987 6 NaN -1.00 211604 1 400 990 0.5 0.3 0.3 3 1044 ON 32.3 P_beta clear 157 20 OFF NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - SR may be in error - Warning: Selected luci dark +1h old! - 1.0" Disturb, NCPA - 10 Iteration, New FF Matrix
20170613_213419 ??? 6.9 323987 5 NaN -1.00 211604 1 400 990 0.5 0.3 0.3 3 1033 ON 35.9 P_beta clear 157 20 OFF NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - SR may be in error - Warning: Selected luci dark +1h old! - 1.0" Disturb, NCPA - 10 Iteration, New FF Matrix
20170613_213439 ??? 6.9 323987 5 NaN -1.00 211604 1 400 990 0.5 0.3 0.3 3 1031 ON 33.7 P_beta clear 157 20 OFF NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - SR may be in error - Warning: Selected luci dark +1h old! - 1.0" Disturb, NCPA - 10 Iteration, New FF Matrix
20170613_213524 ??? 6.9 323987 6 NaN -1.00 211604 1 400 990 0.5 0.3 0.3 3 1029 ON 35.0 P_beta clear 157 20 OFF NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - SR may be in error - Warning: Selected luci dark +1h old! - 1.0" Disturb, NCPA - 10 Iteration, New FF Matrix

1.2" Seeing, NCPA Off, New 10 iteration FF Matrix
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170613_224326 ??? 7.0 323986 4 NaN -1.00 211604 1 400 990 0.8 0.5 0.4 3 974 ON 28.0 P_beta clear 157 20 ON NO - FLTimeout error - PendingCounter error - TimeStamp error - WFSGlobalTimeout error - SR may be in error - Warning: Selected luci dark +3h old! - 1.2" Disturb, No GOPT, No NCPA - 10 Iteration, New FF Matrix
20170613_224342 ??? 6.9 323986 5 NaN -1.00 211604 1 400 990 0.8 0.5 0.4 3 1040 ON 29.0 P_beta clear 157 20 ON NO - FLTimeout error - PendingCounter error - TimeStamp error - WFSGlobalTimeout error - SR may be in error - Warning: Selected luci dark +3h old! - 1.2" Disturb, No GOPT, No NCPA - 10 Iteration, New FF Matrix
20170613_224359 ??? 7.0 323986 4 NaN -1.00 211604 1 400 990 0.8 0.5 0.4 3 989 ON 28.6 P_beta clear 157 20 ON NO - FLTimeout error - PendingCounter error - TimeStamp error - WFSGlobalTimeout error - SR may be in error - Warning: Selected luci dark +3h old! - 1.2" Disturb, No GOPT, No NCPA - 10 Iteration, New FF Matrix
20170613_224421 ??? 7.0 323986 7 NaN -1.00 211604 1 400 990 0.8 0.5 0.4 3 995 ON 28.3 P_beta clear 157 20 ON NO - FLTimeout error - PendingCounter error - TimeStamp error - WFSGlobalTimeout error - SR may be in error - Warning: Selected luci dark +3h old! - 1.2" Disturb, No GOPT, No NCPA - 10 Iteration, New FF Matrix

1.2" Seeing, NCPA On
  • Loop is not stable
  • Loop opens as soon as NCPA is applied

Old FF matrices, New Actuator List (IF list)

  • Can not even set a Flat
  • Not usable

New FF matrices (10 iter), New Recon (4 iter)

1.2" Seeing, NCPA Off
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170613_232202 ??? 7.0 323986 5 NaN -1.00 231742 1 400 990 0.8 0.5 0.4 3 995 ON 25.0 P_beta clear 157 20 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - SR may be in error - Warning: Selected luci dark +3h old! - 1.2" Disturb, No GOPT, No NCPA - 10 Iteration, New FF Matrix
20170613_232222 ??? 7.0 323986 6 NaN -1.00 231742 1 400 990 0.8 0.5 0.4 3 965 ON 22.2 P_beta clear 157 20 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - SR may be in error - Warning: Selected luci dark +3h old! - 1.2" Disturb, No GOPT, No NCPA - 10 Iteration, New FF Matrix
20170613_232240 ??? 7.0 323986 6 NaN -1.00 231742 1 400 990 0.8 0.5 0.4 3 976 ON 27.0 P_beta clear 157 20 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - SR may be in error - Warning: Selected luci dark +3h old! - 1.2" Disturb, No GOPT, No NCPA - 10 Iteration, New FF Matrix
20170613_232258 ??? 7.0 323986 6 NaN -1.00 231742 1 400 990 0.8 0.5 0.4 3 997 ON 26.5 P_beta clear 157 20 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - SR may be in error - Warning: Selected luci dark +3h old! - 1.2" Disturb, No GOPT, No NCPA - 10 Iteration, New FF Matrix

1.2" Seeing, NCPA On
  • Loop is not stable
  • Loop opens as soon as NCPA is applied

New FF matrices (10 iter), New Recon (48 iter)

1.2" Seeing, NCPA On
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170613_232416 ??? 6.9 323986 3 NaN -1.00 231742 1 400 990 0.5 0.4 0.3 3 1094 ON 31.4 P_beta clear 157 20 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - SR may be in error - Warning: Selected luci dark +3h old! - 1.2" Disturb, NCPA - 10 Iteration, New FF Matrix
20170613_232435 ??? 6.9 323986 3 NaN -1.00 231742 1 400 990 0.5 0.4 0.3 3 1087 ON 31.6 P_beta clear 157 20 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - SR may be in error - Warning: Selected luci dark +3h old! - 1.2" Disturb, NCPA - 10 Iteration, New FF Matrix
20170613_232453 ??? 6.9 323986 2 NaN -1.00 231742 1 400 990 0.5 0.4 0.3 3 1084 ON 33.6 P_beta clear 157 20 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - SR may be in error - Warning: Selected luci dark +3h old! - 1.2" Disturb, NCPA - 10 Iteration, New FF Matrix
20170613_232517 ??? 6.9 323986 4 NaN -1.00 231742 1 400 990 0.5 0.4 0.3 3 1080 ON 30.8 P_beta clear 157 20 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - SR may be in error - Warning: Selected luci dark +3h old! - 1.2" Disturb, NCPA - 10 Iteration, New FF Matrix

June 14

Old FF Matrix

LUCI Rotator 210

0.8" Seeing, NCPA Off, Old FF Matrix, Old Recon
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170614_192525 ??? 6.9 323985 7 NaN -1.00 190540 1 400 990 0.5 0.4 0.4 3 1085 ON 36.6 P_beta clear 157 20 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - 0.8" Disturb, No GOPT, No NCPA
20170614_192544 ??? 6.9 323985 2 NaN -1.00 190540 1 400 990 0.5 0.4 0.4 3 1081 ON 36.9 P_beta clear 157 20 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Background correction failed - 0.8" Disturb, No GOPT, No NCPA
20170614_192605 ??? 6.9 323985 7 NaN -1.00 190540 1 400 990 0.5 0.4 0.4 3 1078 ON 37.6 P_beta clear 157 20 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - 0.8" Disturb, No GOPT, No NCPA
20170614_192623 ??? 6.9 323985 1 NaN -1.00 190540 1 400 990 0.5 0.4 0.4 3 1077 ON 35.1 P_beta clear 157 20 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - 0.8" Disturb, No GOPT, No NCPA

0.8" Seeing, NCPA On, Old FF Matrix, Old Recon
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170614_192843 ??? 6.9 323985 4 NaN -1.00 190540 1 400 990 0.5 0.4 0.4 3 1079 ON 34.8 P_beta clear 157 20 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - 0.8" Disturb NCPA
20170614_192945 ??? 6.9 323985 3 NaN -1.00 190540 1 400 990 0.5 0.3 0.3 3 1059 ON 41.6 P_beta clear 157 20 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - 0.8" Disturb NCPA
20170614_193011 ??? 6.9 323985 2 NaN -1.00 190540 1 400 990 0.5 0.3 0.3 3 1063 ON 42.9 P_beta clear 157 20 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - 0.8" Disturb NCPA
20170614_193027 ??? 6.9 323985 2 NaN -1.00 190540 1 400 990 0.5 0.3 0.3 3 1062 ON 38.1 P_beta clear 157 20 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Background correction failed - 0.8" Disturb NCPA
20170614_193053 ??? 6.9 323985 5 NaN -1.00 190540 1 400 990 0.5 0.3 0.3 3 1061 ON 36.5 P_beta clear 157 20 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - 0.8" Disturb NCPA

1.0" Seeing, NCPA Off, Old FF Matrix, Old Recon
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170614_193401 ??? 6.9 323985 1 NaN -1.00 190540 1 400 990 0.6 0.5 0.4 3 1087 ON 34.6 P_beta clear 157 20 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Background correction failed - 1.0" Disturb, No GOPT, No NCPA
20170614_193420 ??? 6.9 323985 1 NaN -1.00 190540 1 400 990 0.6 0.5 0.4 3 1086 ON 30.1 P_beta clear 157 20 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - 1.0" Disturb, No GOPT, No NCPA
20170614_193438 ??? 6.9 323985 5 NaN -1.00 190540 1 400 990 0.6 0.5 0.4 3 1084 ON 35.3 P_beta clear 157 20 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Background correction failed - 1.0" Disturb, No GOPT, No NCPA
20170614_193456 ??? 6.9 323985 3 NaN -1.00 190540 1 400 990 0.6 0.5 0.4 3 1084 ON 35.2 P_beta clear 157 20 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - 1.0" Disturb, No GOPT, No NCPA

1.0" Seeing, NCPA On, Old FF Matrix, New Recon
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170614_201721 ??? 6.9 323985 3 NaN -1.00 201010 1 400 990 0.6 0.5 0.4 3 1092 ON 35.5 P_beta clear 157 20 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Background correction failed - 1.0" Disturb, No GOPT, No NCPA, New Recon
20170614_201737 ??? 6.9 323985 5 NaN -1.00 201010 1 400 990 0.6 0.5 0.4 3 1089 ON 36.5 P_beta clear 157 20 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Background correction failed - 1.0" Disturb, No GOPT, No NCPA, New Recon
20170614_201803 ??? 6.9 323985 3 NaN -1.00 201010 1 400 990 0.6 0.5 0.4 3 1084 ON 32.2 P_beta clear 157 20 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Background correction failed - 1.0" Disturb, No GOPT, No NCPA, New Recon
20170614_201820 ??? 6.9 323985 6 NaN -1.00 201010 1 400 990 0.6 0.5 0.4 3 1079 ON 35.0 P_beta clear 157 20 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - 1.0" Disturb, No GOPT, No NCPA, New Recon
20170614_202220 ??? 6.9 323985 8 NaN -1.00 201010 1 400 990 0.7 0.5 0.4 3 1087 ON 32.7 P_beta clear 157 20 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Warning: Selected luci dark +1h old! - 1.0" Disturb, No GOPT, No NCPA, New Recon
20170614_202238 ??? 6.9 323985 6 NaN -1.00 201010 1 400 990 0.7 0.5 0.4 3 1084 ON 25.1 P_beta clear 157 20 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Warning: Selected luci dark +1h old! - 1.0" Disturb, No GOPT, No NCPA, New Recon
20170614_202255 ??? 6.9 323985 4 NaN -1.00 201010 1 400 990 0.7 0.5 0.4 3 1082 ON 27.0 P_beta clear 157 20 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Background correction failed - Warning: Selected luci dark +1h old! - 1.0" Disturb, No GOPT, No NCPA, New Recon
20170614_202311 ??? 6.9 323985 6 NaN -1.00 201010 1 400 990 0.7 0.5 0.4 3 1099 ON 23.9 P_beta clear 157 20 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Background correction failed - Warning: Selected luci dark +1h old! - 1.0" Disturb, No GOPT, No NCPA, New Recon
20170614_202343 ??? 6.9 323985 7 NaN -1.00 201010 1 400 990 0.6 0.4 0.3 3 1094 ON 27.7 P_beta clear 157 20 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Warning: Selected luci dark +1h old! - 1.0" Disturb, GOPT, No NCPA, New Recon
20170614_202359 ??? 6.9 323985 3 NaN -1.00 201010 1 400 990 0.6 0.4 0.3 3 1084 ON 27.4 P_beta clear 157 20 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Warning: Selected luci dark +1h old! - 1.0" Disturb, GOPT, No NCPA, New Recon
20170614_202440 ??? 6.9 323985 8 NaN -1.00 201010 1 400 990 0.6 0.4 0.3 3 1087 ON 23.7 P_beta clear 157 20 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Background correction failed - Warning: Selected luci dark +1h old! - 1.0" Disturb, GOPT, No NCPA, New Recon
20170614_202502 ??? 6.9 323985 7 NaN -1.00 201010 1 400 990 0.6 0.4 0.3 3 1077 ON 21.5 P_beta clear 157 20 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Warning: Selected luci dark +1h old! - 1.0" Disturb, GOPT, No NCPA, New Recon

1.2" Seeing, NCPA Off, Old FF Matrix, New Recon
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170614_215803 ??? 7.5 323986 5 NaN -1.00 215414 2 153 991 0.4 0.6 0.4 3 2299 ON -1.0 ? -1 -1 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - 1.2" Disturb, No NCPA, No GOPT
20170614_215818 ??? 7.5 323986 6 NaN -1.00 215414 2 153 991 0.4 0.6 0.4 3 2299 ON -1.0 ? -1 -1 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - 1.2" Disturb, No NCPA, No GOPT
20170614_215833 ??? 7.5 323986 5 NaN -1.00 215414 2 153 991 0.4 0.6 0.4 3 2298 ON -1.0 ? -1 -1 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - 1.2" Disturb, No NCPA, No GOPT
20170614_215845 ??? 7.5 323986 6 NaN -1.00 215414 2 153 991 0.4 0.6 0.4 3 2299 ON -1.0 ? -1 -1 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - 1.2" Disturb, No NCPA, No GOPT
20170614_223334 ??? 7.5 323984 6 NaN -1.00 215414 2 153 991 0.4 0.6 0.4 3 2292 ON 0.0 P_beta clear 157 20 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Center of PSF estimation error - Warning: Selected luci dark +3h old! - 1.2" Disturb, No NCPA, No GOPT
20170614_223400 ??? 7.5 323984 7 NaN -1.00 215414 2 153 991 0.4 0.6 0.4 3 2291 ON 0.0 P_beta clear 157 20 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Center of PSF estimation error - Warning: Selected luci dark +3h old! - 1.2" Disturb, No NCPA, No GOPT
20170614_223418 ??? 7.5 323984 7 NaN -1.00 215414 2 153 991 0.4 0.6 0.4 3 2291 ON 0.0 P_beta clear 157 20 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Center of PSF estimation error - Warning: Selected luci dark +3h old! - 1.2" Disturb, No NCPA, No GOPT
20170614_223433 ??? 7.5 323984 5 NaN -1.00 215414 2 153 991 0.4 0.6 0.4 3 2291 ON 0.0 P_beta clear 157 20 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Center of PSF estimation error - Warning: Selected luci dark +3h old! - 1.2" Disturb, No NCPA, No GOPT
20170614_230256 ??? 8.0 323984 5 NaN -1.00 224249 3 66 599 0.9 1.0 1.0 6 5853 ON 0.0 P_beta clear 157 50 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Center of PSF estimation error - Warning: Selected luci dark +4h old! - 1.2" Disturb, No NCPA, No GOPT
20170614_230325 ??? 8.0 323984 4 NaN -1.00 224249 3 66 599 0.9 1.0 1.0 6 5854 ON 0.0 P_beta clear 157 50 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Center of PSF estimation error - Warning: Selected luci dark +4h old! - 1.2" Disturb, No NCPA, No GOPT
20170614_230402 ??? 8.0 323984 4 NaN -1.00 224249 3 66 599 0.9 1.0 1.0 6 5851 ON 0.0 P_beta clear 157 50 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Center of PSF estimation error - Warning: Selected luci dark +4h old! - 1.2" Disturb, No NCPA, No GOPT
20170614_230423 ??? 8.0 323984 2 NaN -1.00 224249 3 66 599 0.9 1.0 1.0 6 5852 ON 1295.2 P_beta clear 157 50 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Could not test SR quality - Warning: Selected luci dark +4h old! - 1.2" Disturb, No NCPA, No GOPT
20170614_233021 ??? 8.2 323984 9 NaN -1.00 231119 4 36 600 1.3 1.7 1.4 6 7834 ON 4190.8 P_beta clear 157 50 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Could not test SR quality - Warning: Selected luci dark +4h old! - 1.2" Disturb, No NCPA, No GOPT
20170614_233059 ??? 8.2 323984 7 NaN -1.00 231119 4 36 600 1.3 1.7 1.4 6 7839 ON 4222.7 P_beta clear 157 50 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Could not test SR quality - Warning: Selected luci dark +4h old! - 1.2" Disturb, No NCPA, No GOPT
20170614_233121 ??? 8.2 323984 8 NaN -1.00 231119 4 36 600 1.3 1.7 1.4 6 7836 ON 4258.2 P_beta clear 157 50 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Could not test SR quality - Warning: Selected luci dark +4h old! - 1.2" Disturb, No NCPA, No GOPT
20170614_233144 ??? 8.2 323984 7 NaN -1.00 231119 4 36 600 1.3 1.7 1.4 6 7834 ON 4566.6 P_beta clear 157 50 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Could not test SR quality - Warning: Selected luci dark +4h old! - 1.2" Disturb, No NCPA, No GOPT
-- %USERSIG{GregoryTaylor - 2017-06-15}%

Comments

No Comment
Topic revision: r2 - 27 Jun 2017, DougMiller
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.