Reconstructor Measurements with Old FF Matrix

16:50
  • Finding the source
  • Closing Loop with reconstructor: /local/aomeas/adsec_calib/M2C/KL_v16/RECs/Rec_20150125_161348.fits
  • Taking flat: /local/aomeas/adsec_calib/flat/Applicable/20170614_400_flat.sav
  • Bottom edge missing, will slow down the loop and put on more modulation
  • Round pupil
  • Saving flat: 20170614_400_flat_2.sav
  • At 12 l/d, the dust that is on the cube became more apparent. I moved Bayside Y, and that helped.
  • Hex: -1.55 -1.24 4.5 34.4 22.6
  • Baysides: -75.5 -49.7 50.1
  • Cube -1.4, 203.7
17:10
  • Preparing to take reconstructors.
  • New Flat: 20170614_400_flat_3.sav
  • Not perfect, but let's get started. Going straight to 400 modes
  • Disturb, same as before: 20160612_225127
  • 4 iterations, closed loop with: Rec_20150125_161348.fits
  • Intmat: 171947
  • Recon: 172122
  • Getting new flat with new recon:
  • 6 l/d at 600 hz, to fill-out edge
  • 20170614_400_flat_4.sav
  • Looks better than #3, but not good enough yet.
17:25
  • 4 iteration reconstructor with new flat and latest recon in closed loop
  • intmat: 172621
  • Recon: 172752
  • New flat: 20170614_400_flat_5.sav
  • Flat #4 is better
  • New flat, starting from an earlier flat (#2): 20170614_400_flat_6.sav
  • The Edge looks better
17:37
  • Intmat, 4 iter: 173703
  • recon: 173829
  • New flat: #7
  • Might be the best one today. (We bloody need TS3)
17:42
  • intmat, 4 iter: 174329
  • recon: 174510
  • New flat: #8
  • I think #7 is as good as I'm going to get. I need to wait for Elliot, then I'll take a long reconstructor.
18:49
  • intmat, 48 iter: 185106
  • Recon: 190540
19:20
  • Testing with Turbulence
  • 0.8" /local/aomeas/adsec_calib/M2C/KL_v16/disturb/CmdDisturb_20170613_184455.fits
  • Gains: 0.49 0.40 0.38 (optimized)
  • No GOPT
  • Dataset: 192525, 192544, 192605, 192623
  • NCPA on, half amplitude
  • GOPT 0.95
  • 192843
  • Too much Ho2, lowering it by 0.1, Ho1 by 0.05
  • 192945, 193011, 193027, 193053

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170703_114919 ??? 9.2 323981 7 NaN 0.37 b1m300 1 300 990 0.5 0.1 0.1 3 133 ON 61.2 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Warning: Selected luci dark +5h old!
20170703_114938 ??? 9.1 323981 7 NaN 0.37 b1m300 1 300 990 0.5 0.1 0.1 3 133 ON 60.6 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Background correction failed - Warning: Selected luci dark +5h old!
20170703_114954 ??? 9.1 323981 7 NaN 0.37 b1m300 1 300 990 0.5 0.1 0.1 3 133 ON 63.0 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Warning: Selected luci dark +5h old!
20170703_115011 ??? 9.1 323981 7 NaN 0.37 b1m300 1 300 990 0.5 0.1 0.1 3 133 ON 61.6 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Background correction failed - Warning: Selected luci dark +5h old!
20170703_115026 ??? 9.1 323981 7 NaN 0.37 b1m300 1 300 990 0.5 0.1 0.1 3 133 ON 62.2 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Warning: Selected luci dark +5h old!

19:32
    • 1.0" /local/aomeas/adsec_calib/M2C/KL_v16/disturb/CmdDisturb_20170613_185854.fits
    • Gain 0.62 0.48 0.38
    • Datasets: 193401, 193420, 193438, 193456

19:44
  • 96 iter intmat!:190540
  • Recon 210010
20:13
  • Back to the 1" test
  • Optimized gain: 0.60 0.48 0.39
  • Dataset: 201721, 201737, 201803, 201820
  • Gopt/NCPA GOPT gain 0.9
  • I think that the amplitudes are wrong for the RETROREF
20:20
  • 1.2" /local/aomeas/adsec_calib/M2C/KL_v16/disturb/CmdDisturb_20170613_190727.fits
  • Gain 0.71 0.48 0.38
  • Dataset: 202220, 202238, 202255, 202311
  • GOPT on NO NCPA: 0.8 gain
  • 202343, 202359, 202440, 202502
20:32
  • Preparing to take bin 2 reconstructors.
  • Waiting for another tour.....
21:47
  • Ready for bin 2
  • Disturb: 214810
  • 4 iter intmat w/ recon: /local/aomeas/adsec_calib/M2C/KL_v16/RECs/Rec_20130916_221257.fits
  • intmat: 215249
  • Recon: 215414
  • Tested with 1.2", Dataset, no LUCI: 215803, 215818, 215833, 215845
  • 48 iter intmat: 215945 990Hz!!!!!
  • 48 iter intmat: 221600
  • recon: 222920
  • Dataset w/ luciframes: 223334, 223400, 223418, 223433
22:34
  • Bin 3 with recon: /local/aomeas/adsec_calib/M2C/KL_v16/RECs/Rec_20130917_170946.fits
  • Disturb: 223952
  • 4iter intmat: 224123
  • recon: 224249
  • 48 iter intmat: 224411
  • Recon: 225826
  • Test with 1.2" disturb: dist_flao1_ts4_atm_s1.2_L040.0_v15.0_ovfreq625.00_sd3892.fits
  • Gain: 0.92 1.0 0.97
  • Datasets: 230256, 230325, 230402, 230423
23:04
  • Bin 4 with recon: Rec_20130917_214654.fits
  • Disturb: 230725
  • Intmat 4 iter: 230943
  • Recon: 231119
  • intmat 48 iter: 231326
  • Recon: 232600
  • Test with 1.2" disturb: dist_flao1_ts4_atm_s1.2_L040.0_v15.0_ovfreq625.00_sd3892.fits
  • Gain: 1.29 1.68 1.38
  • 233021, 233059, 233121, 233144

-- %USERSIG{GregoryTaylor - 2017-06-14}%

Comments

No Comment
Topic revision: r4 - 19 Jul 2017, DougMiller
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback