SX Recon: IF list

16:44
  • Attempting to make a larger reconstructor, in hopes of getting a better flat.
  • 480 modes
  • Intmat Disturb: 165503
  • Intmat: 165823
  • Recon: 165945
  • New disturb:
  • 500 modes
  • optimized_amano_6l_div1_5_600modes.fits
  • Disturb: 170528
  • Intmat: 170639
  • Recon: 170820
  • New flat: 20170518_1_InF.sav
  • 600 mode disturb: optimized_amano_6l_div1_5_600modes.fits
  • Disturb: 171410
  • Intmat: 171510
  • Recon: 171805
  • Non functional
  • New 500 mode using last intmat
  • 172627
  • Not Functional
  • New flat, using the 500 mode reconstructor
  • 20170518_2_InF.sav
17:32
  • Will try new reconstructor using 20170518_1_InF.sav, 400 modes.
  • Intmat disturb: 173341
  • Closed loop, with recon 20170517_201557.fits
  • Intmat: 173509
  • Recon: 173946
  • 48 Iterations
  • Intmat: 174376
  • Recon: 175738
18:35
  • Made larger disturbance: 600_optimized_6l_1.5.fits, to try and get some more signal at the edges.
  • Disturb 185759
  • Intmat (X4):185913
  • Recon: 190052
  • New flat: 20170518_3_InF.sav
  • intmat (X96, because I want to beat down some noise): 190552
  • Recon: 193103
19:35
  • Put 150 in no ICC
  • /local/aomeas/adsec_calib/CMD/disturb/dist_flao2_KL_v20_atm_s1.2_L040.0_v15.0_ovfreq1000.00_sd3892.fits
  • Autogains: 0.46 0.31 0.20
  • Datasets: 194434, 194452, 194505, 194520
  • Gains: 0.46 0.41, 0.20
  • Datasets: 194848, 194903, 194918, 194933
19:50
  • An experiment: 600_optimized_3l.fits
  • Disturb: 195140
  • Intmat (48x): 195624
  • Recon: 200956
  • /local/aomeas/adsec_calib/CMD/disturb/dist_flao2_KL_v20_atm_s1.2_L040.0_v15.0_ovfreq1000.00_sd3892.fits
  • Autogains: 0.55 0.40 0.39
  • 201423, 201437, 201454, 201507
  • Bad reconstructor. Stable, but poor correction.
20:21
  • 600_optimized_6l.fits
  • Disturb: 202054
  • Intmat: 202235
  • 990Hz!!!!
20:38
  • Test 175738
  • Gains 0.65 0.40 0.29
  • local/aomeas/adsec_calib/CMD/disturb/dist_flao2_KL_v20_atm_s1.2_L040.0_v15.0_ovfreq1000.00_sd3892.fits
  • 204027, 204041, 204053, 204106, 204117
20:48
  • Looking at internal source
  • Bayside stages: -73.027 -51.005 35.046
  • 48.3 photons per subap
  • Dataset: 205925,
  • Close loop with gain 0
  • Dataset: 210118, straight line at 0.012
  • 105 Photons per subap
  • Open Loop
  • 210418 Horizontal line
  • Closed loop, 0 gain: 210559, Horizontal line.
  • 389 photons
  • closed loop, 0 gain: 210816
  • 110 photons, bayside stage on: 211129
  • 1600 photons per subap
  • 211450
21:20
  • Vibration test: 212155
21:57
  • Intmat: 214333
  • Recon: 215836
22:05
  • /local/aomeas/adsec_calib/CMD/disturb/dist_flao2_KL_v20_atm_s1.2_L040.0_v15.0_ovfreq1000.00_sd3892.fits
  • Gains: 0.51 0.40 0.38
  • 221124, 221159, 221219, 221237
  • /local/aomeas/adsec_calib/CMD/disturb/dist_flao2_KL_v20_atm_s0.8_L040.0_v15.0_ovfreq1000.00_sd3892.fits
  • Gains 0.34 0.39 0.29
  • 221530, 221546, 221614, 221633
  • /local/aomeas/adsec_calib/CMD/disturb/dist_flao2_KL_v20_atm_s1.0_L040.0_v15.0_ovfreq1000.00_sd3892.fits
  • Gains: 0.49 0.39 0.31
22:57
  • /local/aomeas/adsec_calib/CMD/disturb/dist_flao2_KL_v20_atm_s1.2_L040.0_v15.0_ovfreq1000.00_sd3892.fits
  • Gains: 0.60 0.49 0.31
  • 225853
  • Gains: 0.50 0.49 0.31
  • 230053
-- %USERSIG{GregoryTaylor - 2017-05-18}%
Topic revision: r2 - 18 May 2017, GregoryTaylor
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback