SX RR Recon: IF Actuator List

06:00 Closing loop with new reconstructor and saving new flat
  • Seeing bright/dark spots on pupil
  • Flats have bites out of the edge

06:09 Pupil image with 0.4" seeing (6.0 Lam/D)
  • Closed loop with new 400 mode recon with 0.4" seeing
    • pupil_cl_new_400.jpg
  • Save new flat 20170517_9_InF.sav
  • Open the loop
    • pupil_ol_new_400.jpg
  • Apply new flat
    • pupil_20170517_9_InF.jpg

  • Pupil image with new 400 mode recon with 0.4" seeing in closed loop:
    pupil_cl_new_400.jpg

  • Pupil image with new 400 mode recon with 0.4" seeing in open loop:
    pupil_ol_new_400.jpg

  • Pupil image with new flat 20170517_9_InF.sav:
    pupil_20170517_9_InF.jpg

06:13 Pupil image with no disturbance (6.0 Lam/D)
  • Closed loop with new 400 mode recon with no disturbance
    • pupil_cl_new_400_none.jpg
  • Save new flat 20170517_10_InF.sav
  • Open the loop
    • pupil_ol_new_400_none.jpg
  • Apply new flat
    • pupil_20170517_10_InF_none.jpg

  • Pupil image with new 400 mode recon with no disturbance in closed loop:
    pupil_cl_new_400_none.jpg

  • Pupil image with new 400 mode recon with no disturbance seeing in open loop:
    pupil_ol_new_400_none.jpg

  • Pupil image with new flat 20170517_10_InF.sav:
    pupil_20170517_10_InF_none.jpg

06:28 Create 300 mode recon from 400 mode Interaction Matrix
  • Rec_20170517_182327.fits
  • Close loop with the recon
  • save flat
    • 3 lam/D: 20170517_11_InF.sav
    • 6 lam/D: 20170517_12_InF.sav
  • Close loop with 300 mode recon
    • 6 lam/D: 20170517_13_InF.sav
      • Improve top edge a bit
  • Close loop with 300 modes.
    • Still have ragged edge on flat

18:49
  • login to telescope@obs1
  • ssh ovms@ovms
  • ovmsTelemetryClient -r

19:00 Put Act 6 in no_icc
  • Close Loop
    • no bump at act 6
  • Save Flat
    • 20170517_14_InF.sav
  • Apply flat, 382 modes
  • Close loop with 400
    • >0.35 on act 151, 148, 37. 148 is largest

19:06 Put Act 148 in no_icc

19:51
  • Put actuator 6 in no pos, 7, 37, 564, 148, in no icc
  • Flat: 20170517_16_InF.sav
  • New intmat w/ 4 iterations, 195424
  • Recon:195547
  • 48 iterations: 200126
  • Reconstructor: 201557

20:28
  • Flat 20170516_16_IN
  • New 400 mode recon
  • 1.2" disturbance
  • Opt Gains 0.63, 0.4, 0.38
  • Data
    • 202741
    • 203206
    • 203235
  • Loop opened. Rolled edge at 7-8:00 position

20:47
  • Data
    • 204712

22:29
  • New Reconstructor, new actuator map.
  • /local/aomeas/adsec_calib/CMD/disturb/dist_flao2_KL_v20_atm_s0.8_L040.0_v15.0_ovfreq1000.00_sd3892.fits
  • Data with Alessandro on the telescope
  • 215806
  • 215847
  • 215913
  • 215927
22:32
  • Data with LUCI frames, no Alessandro
  • Gain 0.40 0.30 0.30
  • 222121
  • 222332
  • 222409
  • 222556
22:33
  • Old reconstructor, old actuator map
  • Gains: 0.68 0.41 0.38
  • 224106
  • 224122
  • 224139
  • 224153
23:05
  • Dataset with one pupil illuminated. Pupil Mask 20160209-190618
  • 230402 Left Lower
  • 230718 Left Upper
  • 231337 Right Upper
  • 231443 Right Lower
  • 231620 Upper Right Redux
23:34
  • Flat at 100 hz, 18 lambda/d
  • /local/aomeas/adsec_calib/flat/Applicable/20170517_17_InF.sav

-- %USERSIG{GregoryTaylor - 2017-05-17}%

  • T/T jitter plot showing 60 Hz:
    jitter_w_60Hz.jpg

  • Pupil illumination with Edges:
    pupil_with_edges.jpg
I Attachment Action Size Date Who Comment
jitter_w_60Hz.jpgjpg jitter_w_60Hz.jpg manage 125 K 17 May 2017 - 19:08 DougMiller T/T jitter plot showing 60 Hz
pupil_20170517_10_InF_none.jpgjpg pupil_20170517_10_InF_none.jpg manage 105 K 17 May 2017 - 18:26 DougMiller Pupil image with new flat 20170517_10_InF.sav
pupil_20170517_9_InF.jpgjpg pupil_20170517_9_InF.jpg manage 107 K 17 May 2017 - 18:21 DougMiller Pupil image with new flat 20170517_9_InF.sav
pupil_cl_new_400.jpgjpg pupil_cl_new_400.jpg manage 176 K 17 May 2017 - 18:13 DougMiller Pupil image with new 400 mode recon with 0.4" seeing in closed loop
pupil_cl_new_400_none.jpgjpg pupil_cl_new_400_none.jpg manage 104 K 17 May 2017 - 18:24 DougMiller Pupil image with new 400 mode recon with no disturbance in closed loop
pupil_ol_new_400.jpgjpg pupil_ol_new_400.jpg manage 111 K 17 May 2017 - 18:13 DougMiller Pupil image with new 400 mode recon with 0.4" seeing in open loop
pupil_ol_new_400_none.jpgjpg pupil_ol_new_400_none.jpg manage 135 K 17 May 2017 - 18:26 DougMiller Pupil image with new 400 mode recon with no disturbance seeing in open loop
pupil_with_edges.jpgjpg pupil_with_edges.jpg manage 118 K 18 May 2017 - 15:22 DougMiller Pupil illumination with Edges
Topic revision: r9 - 22 May 2017, DougMiller
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback