SX New Reconstructor with IF Actuator List

An new reconstructor was measure using an SX AdSec with the same bad actuator list as was used to measure the KL_v20 Influence Functions, plus two actuators that now have failed capacitive sensors and two actuators in the no_icc list.

The procedure to measure a new reconstructor is following:
  • Collect 10 mode interaction matrix in open loop
    • Calculate new 10 mode reconstructor
    • Use this for next data collection
  • Collect 10 mode interaction matrix in closed loop
    • Calculate new 10 mode reconstructor
    • Use this for next data collection
  • Collect 36 mode interaction matrix in closed loop
    • Calculate new 36 mode reconstructor
    • Use this for next data collection
  • Collect 153 mode interaction matrix in closed loop
    • Calculate new 153 mode reconstructor
    • Use this for next data collection
  • Collect 400 mode interaction matrix in close loop
    • Calculate new 400 mode reconstructor
    • Use this for next data collection
  • Close the loop with this 400 mode recon and save a new flat
  • Apply the new flat
  • Collect 400 mode interaction matrix in close loop
    • Calculate new 400 mode reconstructor
    • Use this for next data collection
  • Close the loop with this 400 mode recon and save a new flat
  • Apply the new flat
  • Collect 400 mode interaction matrix in close loop
    • Continue this iteration

Data Collection

Details of data collection can be found at

http://wiki.lbto.org/bin/view/AdaptiveOptics/20170516_SX_Recon

22:20 Final Flat
  • 20170517InF.sav

22:55
  • One more 48 iteration reconstructor.
    • Intmat: 230639
    • Recon: 232007

Test New Reconstructor with Input Seeing

23:25 New Recon and 0.8" seeing
  • /local/aomeas/adsec_calib/CMD/disturb/dist_flao2_KL_v20_atm_s0.8_L040.0_v15.0_ovfreq1000.00_sd3892.fits
  • Gains: 0.40 0.32 0.29
  • 232552, 232612, 232625, 232638, 232652

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170516_232625 ??? 7.9 324000 11 NaN -1.00 224222 1 400 990 0.4 0.3 0.3 3 416 ON -1.0 ? -1 -1 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_232638 ??? 7.9 324000 12 NaN -1.00 224222 1 400 990 0.4 0.3 0.3 3 418 ON -1.0 ? -1 -1 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_232652 ??? 7.9 324000 10 NaN -1.00 224222 1 400 990 0.4 0.3 0.3 3 414 ON -1.0 ? -1 -1 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error

  • New 400 Mode Recon with 0.8" Seeing:
    20170516_232625.jpg

23:29 New Recon and 1.0" seeing
  • /local/aomeas/adsec_calib/CMD/disturb/dist_flao2_KL_v20_atm_s1.0_L040.0_v15.0_ovfreq1000.00_sd3892.fits
  • 232914, 232926, 232941, 233107

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170516_232914 ??? 7.9 324000 9 NaN -1.00 224222 1 400 990 0.5 0.3 0.3 3 415 ON -1.0 ? -1 -1 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_232926 ??? 7.9 324000 8 NaN -1.00 224222 1 400 990 0.5 0.3 0.3 3 415 ON -1.0 ? -1 -1 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_232941 ??? 7.9 324000 7 NaN -1.00 224222 1 400 990 0.5 0.3 0.3 3 414 ON -1.0 ? -1 -1 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error

  • new 400 Mode Recon with 1.0" Seeing:
    20170516_232914.jpg

23:34 New Recon and 1.2" seeing
  • /local/aomeas/adsec_calib/CMD/disturb/dist_flao2_KL_v20_atm_s1.2_L040.0_v15.0_ovfreq1000.00_sd3892.fits
  • Gains: 0.40 0.20 0.15
  • Loop is not Stable
  • Edge of shell at 7:00 position rolls even if small HO1 and HO2 gain

-- %USERSIG{DougMiller - 2017-05-17}%
I Attachment Action Size Date Who Comment
20170516_232625.jpgjpg 20170516_232625.jpg manage 155 K 17 May 2017 - 14:13 DougMiller New 400 Mode Recon with 0.8" Seeing
20170516_232914.jpgjpg 20170516_232914.jpg manage 138 K 17 May 2017 - 14:13 DougMiller new 400 Mode Recon with 1.0" Seeing
Topic revision: r1 - 17 May 2017, DougMiller
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.