SX Reconstructor Measurement: IF Actuator List

16:59
  • Getting Started
20:14
  • Closed loop
  • Dataset to track vibration: 201449, 202017
20:31
  • Intmat Disturb, 10 modes, 4 frames/movement, 48 push-pull cycles, 600_optimized_6l.fits
  • 203103
  • Flat used: 20170516_InF_3.sav
  • Intmat taken in closed loop, 0.05 gain, with rec: 20170511_220822, the last 400 mode reconstructor from the 11th
  • 203807
  • Blast! 1000 hz
  • Intmat @ 600Hz 204205
  • Recon: 204331
  • Intmat Disturb, 36 modes, 4 frames/movement, 13 push-pull cycles
  • 204625
  • Taken with last reconstructor, 0.05 gain
  • 204801
  • Recon: 204935, works.
  • Intmat disturb, 66 modes., 4 frames/movement, 7 push-pull cycles, 600_optimized_6l
  • 205222
  • Intmat: 205428
  • Recon: 205658
  • Intmat disturb, 153 modes, 4 frames/movement, 3 push-pull cycles, 600_optimized_6l
  • 210037
  • Intmat: 210136
  • Recon: 210326
  • Intmat disturb: 400 modes, 1 frame/movement, 4 push-pull cycles, 600_optimized_6l
  • 210603
  • Intmat:210731
  • Something went wrong,
  • Intmat disturb: 211107
  • Intmat: 211335
  • Intmad disturb, 400 modes, 2 frame/movement, 2 push-pull cycles, 600_optimized_6l
  • 211804
  • Intmat: 211944
  • Recon: 212120
  • Taking intmat with 184300 recon
  • 212510
  • Recon: 212704
  • Intmat w/ 4 iterations: 213409
  • Recon: 213540
  • Intmat: 214403, 48 iterations
  • Recon: 215912
22:10
  • Datasets: /local/aomeas/adsec_calib/CMD/disturb/dist_flao2_KL_v20_atm_s0.8_L040.0_v15.0_ovfreq1000.00_sd3892.fits
  • Gain: 0.29 0.20 0.28
  • 221700,
  • New Intmat, flat: 20170517InF.sav
  • 222419
  • Recon: 222553
  • Intmat, 48 iterations.
  • 222803
  • Recon: 224222
  • 990 Hz, gain 0.37 0.31 0.29
  • 224807, 224822, 224834, 224849
22:55
  • One more 48 iteration reconstructor.
  • Intmat: 230639
  • Recon: 232007
  • /local/aomeas/adsec_calib/CMD/disturb/dist_flao2_KL_v20_atm_s0.8_L040.0_v15.0_ovfreq1000.00_sd3892.fits
  • Gains: 0.40 0.32 0.29
  • 232552, 232612, 232625, 232638, 232652
  • /local/aomeas/adsec_calib/CMD/disturb/dist_flao2_KL_v20_atm_s1.0_L040.0_v15.0_ovfreq1000.00_sd3892.fits
  • 232914, 232926, 232941, 233107
  • /local/aomeas/adsec_calib/CMD/disturb/dist_flao2_KL_v20_atm_s1.2_L040.0_v15.0_ovfreq1000.00_sd3892.fits
  • Gains: 0.40 0.20 0.15