SX Performance Tests

17:10 Loop Closed
  • Use "Recon List" of actuators
  • Warning message that actuator 148 has high DistAverage. Will leave in for now
  • Looks like reasonable low noise on CCD39

17:17 Dark Telemetry
  • Turn source off
  • Gain 0
  • 4000 frames
  • 171715

Re-Rotator Test

17: Closed loop params for all re-rotator test
  • Recon List of actuators
  • 0.8" seeing
  • Gains 0.71, 0.49, 0.30
  • 400 mode recon
  • bin 1
  • 900 Hz

54.912 - Current configured value

17:37 re-rot = 54.912 - Current configured value
  • 173726
  • 173917
  • 174030
  • 174157

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170516_173726 ??? 7.9 324000 10 NaN -1.00 184300 1 400 990 0.7 0.5 0.3 3 408 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_173917 ??? 7.9 324000 14 NaN -1.00 184300 1 400 990 0.7 0.5 0.3 3 409 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_174030 ??? 7.9 324000 14 NaN -1.00 184300 1 400 990 0.7 0.5 0.3 3 413 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_174157 ??? 7.9 324000 16 NaN -1.00 184300 1 400 990 0.7 0.5 0.3 3 414 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - TimeStamp error - WFSGlobalTimeout error

  • 54.912 - Current configured value:
    20170516_173726.jpg

54.012

17:43 re-rot = 54.012
  • 174312
  • 174342
  • 174404
  • 174429

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170516_174312 ??? 7.9 324000 15 NaN -1.00 184300 1 400 990 0.7 0.5 0.3 3 415 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_174342 ??? 7.9 324000 16 NaN -1.00 184300 1 400 990 0.7 0.5 0.3 3 413 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_174404 ??? 7.9 324000 16 NaN -1.00 184300 1 400 990 0.7 0.5 0.3 3 415 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_174429 ??? 7.9 324000 15 NaN -1.00 184300 1 400 990 0.7 0.5 0.3 3 411 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - TimeStamp error - WFSGlobalTimeout error

  • 54.012:
    20170516_174312.jpg

55.112

17:46 re-rot = 55.112
  • 174645
  • 174703
  • 174737
  • 174758

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170516_174645 ??? 7.9 324000 13 NaN -1.00 184300 1 400 990 0.7 0.5 0.3 3 416 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_174703 ??? 7.9 324000 12 NaN -1.00 184300 1 400 990 0.7 0.5 0.3 3 418 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_174737 ??? 7.9 324000 14 NaN -1.00 184300 1 400 990 0.7 0.5 0.3 3 415 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_174758 ??? 7.9 324000 16 NaN -1.00 184300 1 400 990 0.7 0.5 0.3 3 418 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - TimeStamp error - WFSGlobalTimeout error

  • 55.112:
    20170516_174645.jpg

55.212

18:04 re_rot = 55.212
  • 180437
  • 180545
  • 180605
  • 180641

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170516_180437 ??? 7.9 324000 7 NaN -1.00 184300 1 400 990 0.7 0.5 0.3 3 425 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_180545 ??? 7.9 324000 10 NaN -1.00 184300 1 400 990 0.7 0.5 0.3 3 423 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_180605 ??? 7.9 324000 11 NaN -1.00 184300 1 400 990 0.7 0.5 0.3 3 422 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_180641 ??? 7.9 324000 13 NaN -1.00 184300 1 400 990 0.7 0.5 0.3 3 425 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error

  • 55.212:
    20170516_180437.jpg

55.312

18:05 re-rot = 55.312
  • 180835
  • 180909
  • 180927
  • 180953

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170516_180835 ??? 7.9 324000 7 NaN -1.00 184300 1 400 990 0.7 0.5 0.3 3 426 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_180909 ??? 7.9 324000 4 NaN -1.00 184300 1 400 990 0.7 0.5 0.3 3 426 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_180927 ??? 7.9 324000 8 NaN -1.00 184300 1 400 990 0.7 0.5 0.3 3 427 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_180953 ??? 7.9 324000 3 NaN -1.00 184300 1 400 990 0.7 0.5 0.3 3 421 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error

  • 55.312:
    20170516_180835.jpg

55.412

18:10 re-rot = 55.412 (striping)
  • 181044
  • 181109
  • 181135
  • 181151

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170516_181044 ??? 7.9 324000 12 NaN -1.00 184300 1 400 990 0.7 0.5 0.3 3 418 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_181109 ??? 7.9 324000 4 NaN -1.00 184300 1 400 990 0.7 0.5 0.3 3 429 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_181135 ??? 7.9 324000 10 NaN -1.00 184300 1 400 990 0.7 0.5 0.3 3 426 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_181151 ??? 7.9 324000 1 NaN -1.00 184300 1 400 990 0.7 0.5 0.3 3 428 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error

  • 55.412:
    20170516_181044.jpg

54.912 - Current configured value

18:14 re-rot = 54.912
  • 181424
  • 181442
  • 181510
  • 181530

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170516_181424 ??? 7.9 324000 8 NaN -1.00 184300 1 400 990 0.7 0.5 0.3 3 426 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_181442 ??? 7.9 324000 14 NaN -1.00 184300 1 400 990 0.7 0.5 0.3 3 429 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_181510 ??? 7.9 324000 16 NaN -1.00 184300 1 400 990 0.7 0.5 0.3 3 431 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_181530 ??? 7.8 324000 16 NaN -1.00 184300 1 400 990 0.7 0.5 0.3 3 435 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error

  • 54.912 - Current configured value - 2:
    20170516_181424.jpg

54.812

18:16 re-rot = 54.812
  • 181637
  • 181707
  • 181723
  • 181737

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170516_181637 ??? 7.9 324000 11 NaN -1.00 184300 1 400 990 0.7 0.5 0.3 3 430 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_181707 ??? 7.8 324000 11 NaN -1.00 184300 1 400 990 0.7 0.5 0.3 3 437 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_181723 ??? 7.8 324000 15 NaN -1.00 184300 1 400 990 0.7 0.5 0.3 3 441 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_181737 ??? 7.9 324000 12 NaN -1.00 184300 1 400 990 0.7 0.5 0.3 3 432 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error

  • 54.812:
    20170516_181637.jpg

54.712

18:18 re-rot = 54.712 (striping)
  • 181838
  • 181854
  • 181918
  • 181941

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170516_181838 ??? 7.8 324000 15 NaN -1.00 184300 1 400 990 0.7 0.5 0.3 3 438 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_181854 ??? 7.8 324000 15 NaN -1.00 184300 1 400 990 0.7 0.5 0.3 3 436 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_181918 ??? 7.8 324000 16 NaN -1.00 184300 1 400 990 0.7 0.5 0.3 3 436 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_181941 ??? 7.8 324000 16 NaN -1.00 184300 1 400 990 0.7 0.5 0.3 3 434 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error

  • 54.712:
    20170516_181838.jpg

54.612

18:20 re-rot = 54.612 (striping)
  • 182039
  • 182103
  • 182121
  • 182136

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170516_182039 ??? 7.8 324000 10 NaN -1.00 184300 1 400 990 0.7 0.5 0.3 3 433 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_182103 ??? 7.8 324000 15 NaN -1.00 184300 1 400 990 0.7 0.5 0.3 3 438 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_182121 ??? 7.8 324000 9 NaN -1.00 184300 1 400 990 0.7 0.5 0.3 3 438 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_182136 ??? 7.8 324000 13 NaN -1.00 184300 1 400 990 0.7 0.5 0.3 3 439 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error

  • 54.612:
    20170516_182039.jpg

Comparison of Measured disturbance (WFS) and Input Disturbance

400 Mode Recon

0.8" seeing disturbance

18:23 All gains 0.0
  • 182327
  • 182358
  • 182419
  • 182438

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170516_182327 ??? 7.8 324000 6 NaN -1.00 184300 1 400 990 0.0 -1.0 -1.0 3 438 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_182358 ??? 7.9 324000 11 NaN -1.00 184300 1 400 990 0.0 -1.0 -1.0 3 430 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_182419 ??? 7.8 324000 18 NaN -1.00 184300 1 400 990 0.0 -1.0 -1.0 3 441 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_182438 ??? 7.8 324000 10 NaN -1.00 184300 1 400 990 0.0 -1.0 -1.0 3 436 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error

  • 400 Mode Recon, 0.8" seeing disturbance, All gains 0.0:
    20170516_182327.jpg

18:27 T/T = 0.7 other gains 0.0
  • 182730
  • 182753
  • 182816
  • 182817

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170516_182730 ??? 7.8 324000 14 NaN -1.00 184300 1 400 990 0.7 -1.0 -1.0 3 439 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_182753 ??? 7.8 324000 7 NaN -1.00 184300 1 400 990 0.7 -1.0 -1.0 3 442 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_182816 ??? 7.8 324000 11 NaN -1.00 184300 1 400 990 0.7 -1.0 -1.0 3 438 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error

  • 400 Mode Recon, 0.8" seeing disturbance, T/T = 0.7 other gains 0.0:
    20170516_182730.jpg

0.4" seeing disturbance

19:41 All gains 0.0
  • 194124
  • 194154
  • 194256
  • 194316

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170516_194124 ??? 7.9 324000 7 NaN -1.00 184300 1 400 990 0.0 -1.0 -1.0 3 426 ON -1.0 ? -1 -1 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_194154 ??? 7.9 324000 13 NaN -1.00 184300 1 400 990 0.0 -1.0 -1.0 3 420 ON -1.0 ? -1 -1 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_194256 ??? 7.9 324000 20 NaN -1.00 184300 1 400 990 0.0 -1.0 -1.0 3 425 ON -1.0 ? -1 -1 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_194316 ??? 7.9 324000 17 NaN -1.00 184300 1 400 990 0.0 -1.0 -1.0 3 424 ON -1.0 ? -1 -1 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error

  • 400 Mode Recon, 0.4" seeing disturbance, All gains 0.0:
    20170516_194124.jpg

19:43 T/T= 0.5 other gains 0.0
  • 194359
  • 194412
  • 194424
  • 194436

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170516_194359 ??? 7.9 324000 20 NaN -1.00 184300 1 400 990 0.5 -1.0 -1.0 3 425 ON -1.0 ? -1 -1 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_194412 ??? 7.9 324000 17 NaN -1.00 184300 1 400 990 0.5 -1.0 -1.0 3 424 ON -1.0 ? -1 -1 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_194424 ??? 7.9 324000 14 NaN -1.00 184300 1 400 990 0.5 -1.0 -1.0 3 424 ON -1.0 ? -1 -1 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_194436 ??? 7.9 324000 15 NaN -1.00 184300 1 400 990 0.5 -1.0 -1.0 3 423 ON -1.0 ? -1 -1 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error

  • 400 Mode Recon, 0.4" seeing disturbance, T/T = 0.7 other gains 0.0:
    20170516_194359.jpg

300 Mode Recon

0.8" seeing disturbance

18:33 All gains 0.0
  • 183345
  • 183401
  • 183426
  • 183438

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170516_183345 ??? 7.8 324000 19 NaN -1.00 062006 1 300 990 0.0 -1.0 -1.0 3 446 ON -1.0 ? -1 -1 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_183401 ??? 7.8 324000 16 NaN -1.00 062006 1 300 990 0.0 -1.0 -1.0 3 446 ON -1.0 ? -1 -1 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_183426 ??? 7.8 324000 17 NaN -1.00 062006 1 300 990 0.0 -1.0 -1.0 3 442 ON -1.0 ? -1 -1 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_183438 ??? 7.8 324000 18 NaN -1.00 062006 1 300 990 0.0 -1.0 -1.0 3 440 ON -1.0 ? -1 -1 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error

  • 300 Mode Recon, 0.8" seeing disturbance, All gains 0.0:
    20170516_183345.jpg

18:35 T/T = 0.7, other gains 0.0
  • 183516
  • 183528
  • 183544
  • 183602

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170516_183516 ??? 7.8 324000 18 NaN -1.00 062006 1 300 990 0.7 -1.0 -1.0 3 451 ON -1.0 ? -1 -1 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_183528 ??? 7.8 324000 18 NaN -1.00 062006 1 300 990 0.7 -1.0 -1.0 3 450 ON -1.0 ? -1 -1 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_183544 ??? 7.8 324000 16 NaN -1.00 062006 1 300 990 0.7 -1.0 -1.0 3 451 ON -1.0 ? -1 -1 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_183602 ??? 7.8 324000 17 NaN -1.00 062006 1 300 990 0.7 -1.0 -1.0 3 448 ON -1.0 ? -1 -1 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error

  • 300 Mode Recon, 0.8" seeing disturbance, T/T = 0.7 other gains 0.0:
    20170516_183516.jpg

0.4" seeing disturbance

19:48 All gains 0.0
  • 194837
  • 194848
  • 194900
  • 194911

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170516_194837 ??? 7.9 324000 14 NaN -1.00 062006 1 300 990 0.0 -1.0 -1.0 3 425 ON -1.0 ? -1 -1 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_194848 ??? 7.9 324000 15 NaN -1.00 062006 1 300 990 0.0 -1.0 -1.0 3 426 ON -1.0 ? -1 -1 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_194900 ??? 7.9 324000 15 NaN -1.00 062006 1 300 990 0.0 -1.0 -1.0 3 426 ON -1.0 ? -1 -1 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_194911 ??? 7.9 324000 15 NaN -1.00 062006 1 300 990 0.0 -1.0 -1.0 3 423 ON -1.0 ? -1 -1 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error

  • 300 Mode Recon, 0.4" seeing disturbance, All gains 0.0:
    20170516_194837.jpg

19:49 T/T = 0.5, other gains 0.0
  • 194934
  • 194946
  • 194958
  • 195009

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170516_194934 ??? 7.9 324000 14 NaN -1.00 062006 1 300 990 0.5 -1.0 -1.0 3 419 ON -1.0 ? -1 -1 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - long stop of 56 frames at frame 3181
20170516_194946 ??? 7.9 324000 12 NaN -1.00 062006 1 300 990 0.5 -1.0 -1.0 3 423 ON -1.0 ? -1 -1 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_194958 ??? 7.9 324000 12 NaN -1.00 062006 1 300 990 0.5 -1.0 -1.0 3 423 ON -1.0 ? -1 -1 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_195009 ??? 7.9 324000 12 NaN -1.00 062006 1 300 990 0.5 -1.0 -1.0 3 421 ON -1.0 ? -1 -1 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error

  • 4300 Mode Recon, 0.4" seeing disturbance, T/T = 0.7 other gains 0.0:
    20170516_194934.jpg

Performance with various input seeing disturbance values

300 modes

0.8"

18:38
  • Seeing = 0.8"
  • Opt Gain 0.75, 0.49, 0.31
  • 183830
  • 183851
  • 183905
  • 183917

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170516_183830 ??? 7.8 324000 19 NaN -1.00 062006 1 300 990 0.8 0.5 0.3 3 447 ON -1.0 ? -1 -1 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_183851 ??? 7.8 324000 14 NaN -1.00 062006 1 300 990 0.8 0.5 0.3 3 443 ON -1.0 ? -1 -1 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_183905 ??? 7.8 324000 16 NaN -1.00 062006 1 300 990 0.8 0.5 0.3 3 445 ON -1.0 ? -1 -1 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_183917 ??? 7.8 324000 13 NaN -1.00 062006 1 300 990 0.8 0.5 0.3 3 447 ON -1.0 ? -1 -1 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error

  • 300 modes, 0.8" seeing:
    20170516_183830.jpg

1.0"

18:41
  • Seeing 1.0"
  • Opt Gain 0.93, 0.50. 0.39
  • 184130
  • 184148
  • 184207
  • 184219

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170516_184130 ??? 7.8 324000 15 NaN -1.00 062006 1 300 990 0.9 0.5 0.4 3 449 ON -1.0 ? -1 -1 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_184148 ??? 7.8 324000 17 NaN -1.00 062006 1 300 990 0.9 0.5 0.4 3 448 ON -1.0 ? -1 -1 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_184207 ??? 7.8 324000 16 NaN -1.00 062006 1 300 990 0.9 0.5 0.4 3 446 ON -1.0 ? -1 -1 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_184219 ??? 7.8 324000 15 NaN -1.00 062006 1 300 990 0.9 0.5 0.4 3 449 ON -1.0 ? -1 -1 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error

  • 300 modes, 1.0" seeing:
    20170516_184130.jpg

1.2"

19:04
  • Seeing 1.2"
  • Opt Gain 1.0, 0.59, 0.40
  • 190425
  • 190448
  • 190511
  • 190531

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170516_190425 ??? 7.8 324000 12 NaN -1.00 062006 1 300 990 1.0 0.6 0.4 3 450 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_190448 ??? 7.8 324000 10 NaN -1.00 062006 1 300 990 1.0 0.6 0.4 3 451 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_190511 ??? 7.8 324000 11 NaN -1.00 062006 1 300 990 1.0 0.6 0.4 3 448 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_190531 ??? 7.8 324000 13 NaN -1.00 062006 1 300 990 1.0 0.6 0.4 3 452 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - TimeStamp error - WFSGlobalTimeout error

  • 300 modes, 1.2" seeing:
    20170516_190425.jpg

1.5"

19:03
  • Seeing 1.5"
  • Opt Gain 1.11, 0.60, 0.40
  • 190753
  • 190811
  • 190832
  • 190843

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170516_190753 ??? 7.9 324000 12 NaN -1.00 062006 1 300 990 1.1 0.6 0.4 3 412 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_190811 ??? 7.9 324000 8 NaN -1.00 062006 1 300 990 1.1 0.6 0.4 3 411 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_190832 ??? 7.9 324000 10 NaN -1.00 062006 1 300 990 1.1 0.6 0.4 3 409 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_190843 ??? 7.9 324000 5 NaN -1.00 062006 1 300 990 1.1 0.6 0.4 3 413 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - TimeStamp error - WFSGlobalTimeout error

  • 300 modes, 1.5" seeing:
    20170516_190753.jpg

2.0"

19:10
  • Seeing 2.0"
  • Opt Gain 1.45, 0.68, 0.41
  • 191046
  • 191102
  • 191115
  • 191128

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170516_191046 ??? 7.9 324000 12 NaN -1.00 062006 1 300 990 1.4 0.7 0.4 3 412 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_191102 ??? 7.9 324000 5 NaN -1.00 062006 1 300 990 1.4 0.7 0.4 3 408 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_191115 ??? 7.9 324000 15 NaN -1.00 062006 1 300 990 1.4 0.7 0.4 3 411 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_191128 ??? 7.9 324000 9 NaN -1.00 062006 1 300 990 1.4 0.7 0.4 3 410 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - TimeStamp error - WFSGlobalTimeout error

  • 300 modes, 2.0" seeing:
    20170516_191046.jpg

400 modes

0.8"

19:15
  • Seeing 0.8"
  • Opt Gain 0.77. 0.40, 0.31
  • 191500
  • 191519
  • 191538
  • 191633

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170516_191500 ??? 7.9 324000 13 NaN -1.00 184300 1 400 990 0.8 0.4 0.3 3 409 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_191519 ??? 7.9 324000 11 NaN -1.00 184300 1 400 990 0.8 0.4 0.3 3 413 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_191538 ??? 7.9 324000 15 NaN -1.00 184300 1 400 990 0.8 0.4 0.3 3 413 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_191633 ??? 7.9 324000 17 NaN -1.00 184300 1 400 990 0.8 0.4 0.3 3 407 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - TimeStamp error - WFSGlobalTimeout error

  • 400 modes, 0.8" seeing:
    20170516_191500.jpg

1.0"

19:19
  • Seeing 1.0"
  • Opt Gain 0.82, 0.49, 0.31
  • 191940
  • 191957
  • 192017
  • 192034

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170516_191940 ??? 7.9 324000 17 NaN -1.00 184300 1 400 990 0.8 0.5 0.3 3 411 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_191957 ??? 7.9 324000 15 NaN -1.00 184300 1 400 990 0.8 0.5 0.3 3 416 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_192017 ??? 7.9 324000 15 NaN -1.00 184300 1 400 990 0.8 0.5 0.3 3 415 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_192034 ??? 7.9 324000 12 NaN -1.00 184300 1 400 990 0.8 0.5 0.3 3 413 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - TimeStamp error - WFSGlobalTimeout error

  • 400 modes, 1.0" seeing:
    20170516_191940.jpg

1.2"

19:23
  • Seeing 1.2"
  • Opt Gain 1.04, 0.58, 0.31
  • 192319
  • 192338
  • 192350
  • 192404

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170516_192319 ??? 7.9 324000 19 NaN -1.00 184300 1 400 990 1.0 0.6 0.3 3 411 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_192338 ??? 7.9 324000 13 NaN -1.00 184300 1 400 990 1.0 0.6 0.3 3 415 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_192350 ??? 7.9 324000 10 NaN -1.00 184300 1 400 990 1.0 0.6 0.3 3 415 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_192404 ??? 7.9 324000 11 NaN -1.00 184300 1 400 990 1.0 0.6 0.3 3 415 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - TimeStamp error - WFSGlobalTimeout error

  • 400 modes, 1.2" seeing:
    20170516_192319.jpg

1.5"

19:32
  • Seeing 1.5"
  • Opt Gain - Always safe-skips and does not complete
  • Manual Gain 1.1, 0.6, 0.4
  • 193209 safe-skip near beginning of data set and for most of data set

  • Manual Gain 1.1, 0.5, 0.3
  • safe-skip to 100%

  • Manual Gain 1.1, 05, 0./2
  • 193606
  • 193622

  • HO2 = 0.3
  • 193706 (bit of dark at 7:00)

  • HO2 = 0.35
  • 193741
  • 193755

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170516_193209 ??? 8.0 324000 13 NaN -1.00 184300 1 400 990 1.1 0.6 0.4 3 391 ON -1.0 ? -1 -1 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_193606 ??? 7.9 324000 18 NaN -1.00 184300 1 400 990 1.1 0.5 0.2 3 411 ON -1.0 ? -1 -1 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_193622 ??? 7.9 324000 18 NaN -1.00 184300 1 400 990 1.1 0.5 0.2 3 411 ON -1.0 ? -1 -1 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_193706 ??? 7.9 324000 14 NaN -1.00 184300 1 400 990 1.1 0.5 0.3 3 417 ON -1.0 ? -1 -1 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_193741 ??? 7.9 324000 11 NaN -1.00 184300 1 400 990 1.1 0.5 0.3 3 415 ON -1.0 ? -1 -1 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170516_193755 ??? 8.0 324000 7 NaN -1.00 184300 1 400 990 1.1 0.5 0.3 3 382 ON -1.0 ? -1 -1 ON NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error

  • 400 modes, 1.5" seeing:
    20170516_193606.jpg

22:48 First 48 iteration Recon with IF actuator list
  • 224849
  • See other TWiki log for today

-- %USERSIG{DougMiller - 2017-05-16}%
I Attachment Action Size Date Who Comment
20170516_173726.jpgjpg 20170516_173726.jpg manage 141 K 17 May 2017 - 12:48 DougMiller 54.912 - Current configured value
20170516_174312.jpgjpg 20170516_174312.jpg manage 138 K 17 May 2017 - 12:49 DougMiller 54.012
20170516_174645.jpgjpg 20170516_174645.jpg manage 141 K 17 May 2017 - 12:50 DougMiller 55.112
20170516_180437.jpgjpg 20170516_180437.jpg manage 147 K 17 May 2017 - 12:49 DougMiller 55.212
20170516_180835.jpgjpg 20170516_180835.jpg manage 150 K 17 May 2017 - 12:50 DougMiller 55.312
20170516_181044.jpgjpg 20170516_181044.jpg manage 153 K 17 May 2017 - 12:51 DougMiller 55.412
20170516_181424.jpgjpg 20170516_181424.jpg manage 143 K 17 May 2017 - 12:52 DougMiller 54.912 - Current configured value - 2
20170516_181637.jpgjpg 20170516_181637.jpg manage 151 K 17 May 2017 - 12:52 DougMiller 54.812
20170516_181838.jpgjpg 20170516_181838.jpg manage 163 K 17 May 2017 - 12:52 DougMiller 54.712
20170516_182039.jpgjpg 20170516_182039.jpg manage 164 K 17 May 2017 - 12:53 DougMiller 54.612
20170516_182327.jpgjpg 20170516_182327.jpg manage 104 K 17 May 2017 - 12:54 DougMiller 400 Mode Recon, 0.8" seeing disturbance, All gains 0.0
20170516_182730.jpgjpg 20170516_182730.jpg manage 105 K 17 May 2017 - 12:55 DougMiller 400 Mode Recon, 0.8" seeing disturbance, T/T = 0.7 other gains 0.0
20170516_183345.jpgjpg 20170516_183345.jpg manage 103 K 17 May 2017 - 12:58 DougMiller 300 Mode Recon, 0.8" seeing disturbance, All gains 0.0
20170516_183516.jpgjpg 20170516_183516.jpg manage 105 K 17 May 2017 - 12:58 DougMiller 300 Mode Recon, 0.8" seeing disturbance, T/T = 0.7 other gains 0.0
20170516_183830.jpgjpg 20170516_183830.jpg manage 139 K 17 May 2017 - 13:00 DougMiller 300 modes, 0.8" seeing
20170516_184130.jpgjpg 20170516_184130.jpg manage 128 K 17 May 2017 - 13:01 DougMiller 300 modes, 1.0" seeing
20170516_190425.jpgjpg 20170516_190425.jpg manage 133 K 17 May 2017 - 13:10 DougMiller 300 modes, 1.2" seeing
20170516_190753.jpgjpg 20170516_190753.jpg manage 128 K 17 May 2017 - 13:11 DougMiller 300 modes, 1.5" seeing
20170516_191046.jpgjpg 20170516_191046.jpg manage 152 K 17 May 2017 - 13:11 DougMiller 300 modes, 2.0" seeing
20170516_191500.jpgjpg 20170516_191500.jpg manage 153 K 17 May 2017 - 13:12 DougMiller 400 modes, 0.8" seeing
20170516_191940.jpgjpg 20170516_191940.jpg manage 142 K 17 May 2017 - 13:13 DougMiller 400 modes, 1.2" seeing
20170516_192319.jpgjpg 20170516_192319.jpg manage 139 K 17 May 2017 - 13:13 DougMiller 400 modes, 1.2" seeing
20170516_193606.jpgjpg 20170516_193606.jpg manage 137 K 17 May 2017 - 13:14 DougMiller 400 modes, 1.5" seeing
20170516_194124.jpgjpg 20170516_194124.jpg manage 99 K 17 May 2017 - 12:56 DougMiller 400 Mode Recon, 0.4" seeing disturbance, All gains 0.0
20170516_194359.jpgjpg 20170516_194359.jpg manage 109 K 17 May 2017 - 12:57 DougMiller 400 Mode Recon, 0.4" seeing disturbance, T/T = 0.7 other gains 0.0
20170516_194837.jpgjpg 20170516_194837.jpg manage 108 K 17 May 2017 - 12:59 DougMiller 300 Mode Recon, 0.4" seeing disturbance, All gains 0.0
20170516_194934.jpgjpg 20170516_194934.jpg manage 113 K 17 May 2017 - 12:59 DougMiller 4300 Mode Recon, 0.4" seeing disturbance, T/T = 0.7 other gains 0.0
Topic revision: r3 - 17 May 2017, DougMiller
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback