SX Performance Tests with RR

Actuator list:

# Guido confirmed on 20170503 that there are no missing magnets on TS5
476 : 1 : 0 : 0 : 20151002 : GB : after TSS refurbishment based on Roberto's measurements actuators does not apply current
539 : 1 : 0 : 0 : 20151002 : GB : after TSS refurbishment based on Roberto's measurements actuators does not apply current
#
# No Position
#
552 : 0 : 1 : 0 : 20170503 : DLM : Tried to put it back in but get IDL An in-use...bla error on load program 552,00260318um
14 : 0 : 1 : 0 : 20150521 : GB : In no_pos list in old flat (20150513 flat). However, was able to add the other 4 in the cross back in
#
# Actuators not used when Influence functions were measured (from m2c.fits)
#
2 : 0 : 1 : 0 : 20170509 : DLM : Actuators not in Influence Functions
32 : 0 : 1 : 0 : 20170509 : DLM : Actuators not in Influence Functions
165 : 0 : 1 : 0 : 20170509 : DLM : Actuators not in Influence Functions
373 : 0 : 1 : 0 : 20170509 : DLM : Actuators not in Influence Functions
451 : 0 : 1 : 0 : 20170509 : DLM : Actuators not in Influence Functions
511 : 0 : 1 : 0 : 20170509 : DLM : Actuators not in Influence Functions
578 : 0 : 1 : 0 : 20170509 : DLM : Actuators not in Influence Functions
#
# Actuators not used when Reconstructor Matrix was measured (from Rec_20160229_184300.fits, 20160229_172130_stability_default.sav
#
1 : 0 : 1 : 0 : 20170509 : DLM : Actuators not in Reconstructor Matrix
6 : 0 : 1 : 0 : 20170509 : DLM : Actuators not in Reconstructor Matrix
37 : 0 : 1 : 0 : 20170509 : DLM : Actuators not in Reconstructor Matrix
216 : 0 : 1 : 0 : 20170509 : DLM : Actuators not in Reconstructor Matrix
243 : 0 : 1 : 0 : 20170509 : DLM : Actuators not in Reconstructor Matrix
262 : 0 : 1 : 0 : 20170509 : DLM : Actuators not in Reconstructor Matrix
297 : 0 : 1 : 0 : 20170509 : DLM : Actuators not in Reconstructor Matrix
340 : 0 : 1 : 0 : 20170509 : DLM : Actuators not in Reconstructor Matrix
385 : 0 : 1 : 0 : 20170509 : DLM : Actuators not in Reconstructor Matrix
393 : 0 : 1 : 0 : 20170509 : DLM : Actuators not in Reconstructor Matrix
409 : 0 : 1 : 0 : 20170509 : DLM : Actuators not in Reconstructor Matrix
483 : 0 : 1 : 0 : 20170509 : DLM : Actuators not in Reconstructor Matrix
484 : 0 : 1 : 0 : 20170509 : DLM : Actuators not in Reconstructor Matrix
501 : 0 : 1 : 0 : 20170509 : DLM : Actuators not in Reconstructor Matrix
530 : 0 : 1 : 0 : 20170509 : DLM : Actuators not in Reconstructor Matrix
541 : 0 : 1 : 0 : 20170509 : DLM : Actuators not in Reconstructor Matrix
546 : 0 : 1 : 0 : 20170509 : DLM : Actuators not in Reconstructor Matrix
654 : 0 : 1 : 0 : 20170509 : DLM : Actuators not in Reconstructor Matrix
#
# No ICC
#
149 : 0 : 0 : 1 : 20170504 : DLM : High forces in flat 0.2N and in CL 0.27N
332 : 0 : 0 : 1 : 20170504 : DLM : Jump in CL to high forces of -0.29N

21:11
  • Starting over.
  • Bin4 200 Hz, /local/aomeas/adsec_calib/M2C/KL_v20/RECs/Rec_20160229_205357.fits
  • 20 Img,
  • mag 14.4
  • Gains: 2.67, 0.55, 0.55
  • 20 img at 20s 213052
  • No images 213854, 213920, 213948, 214012
  • /local/aomeas/adsec_calib/CMD/disturb/dist_flao2_KL_v18_atm_s0.8_L040.0_v15.0_ovfreq625.00_sd1983.fits
  • 214120
  • Bin 3, 200 Hz /local/aomeas/adsec_calib/M2C/KL_v18/RECs/Rec_20160220_203720.fits
  • /local/aomeas/adsec_calib/CMD/disturb/dist_flao2_KL_v18_atm_s0.8_L040.0_v15.0_ovfreq625.00_sd1983.fits
  • 13.5 mag
  • Gains: 0.94 1.14 1.14
  • 5s luci frames: 215643,
  • No luci frames: 215848, 220102, 220127, 220151
  • Bin 2, 625 Hz, 12.1 mag. /local/aomeas/adsec_calib/CMD/disturb/dist_flao2_KL_v18_atm_s0.8_L040.0_v15.0_ovfreq625.00_sd1983.fits
  • Gains: 1.34 0.60, 0.55
  • 1s exposures, 20 frames. 221646, 221737, 221816, 221850, 221926
  • Bin 2 990Hz 11.0 mag
  • Gains, 0.94 0.51 0.39
  • 222518, 222833,
  • /local/aomeas/adsec_calib/CMD/disturb/dist_flao2_KL_v20_atm_s0.8_L040.0_v15.0_ovfreq1000.00_sd3892.fits
  • Gains: 0.90 0.40 0.31
  • 223550, 223635, 223715, 223756, 223833
  • Bin 1 990Hz
  • Dataset w/o light at 0 gain: 224518
  • 7.6 mag
  • Gains: 0.78, 0.50 0.30
  • 225440, 225737, 225801, 225828, 225852
  • 231148
  • Noise Data Set: 231431
  • ccd39 - binning 1
    Speed: 2500 kpix/sec - RON (ADU): 20.05 - RON (e-): 10.03 (estimated)
    Speed: 890 kpix/sec - RON (ADU): 12.57 - RON (e-): 6.28 (estimated)
    Speed: 400 kpix/sec - RON (ADU): 11.60 - RON (e-): 5.80 (estimated)
  • ------------------------------ SUMMARY ------------------------------------
    Bin: 1 - Framerate 990 Hz (2500 kpix/sec) - RON (e-): 9.49 (estimated)
    Bin: 2 - Framerate 990 Hz ( 800 kpix/sec) - RON (e-): 6.13 (estimated)
    Bin: 2 - Framerate 625 Hz ( 380 kpix/sec) - RON (e-): 5.65 (estimated)
    Bin: 2 - Framerate 400 Hz ( 380 kpix/sec) - RON (e-): 5.64 (estimated)
    Bin: 3 - Framerate 200 Hz ( 380 kpix/sec) - RON (e-): 5.64 (estimated)
    Bin: 4 - Framerate 300 Hz ( 335 kpix/sec) - RON (e-): 5.69 (estimated)
    Bin: 4 - Framerate 200 Hz ( 335 kpix/sec) - RON (e-): 5.72 (estimated)
    Bin: 4 - Framerate 105 Hz ( 335 kpix/sec) - RON (e-): 5.78 (estimated)