SX Reconstructor Measurement

Loop Closed with the following actuators removed:

# No Current
#
# Guido confirmed on 20170503 that there are no missing magnets on TS5
476 : 1 : 0 : 0 : 20151002 : GB : after TSS refurbishment based on Roberto's measurements actuators does not apply current
539 : 1 : 0 : 0 : 20151002 : GB : after TSS refurbishment based on Roberto's measurements actuators does not apply current

## No Position
#
552 : 0 : 1 : 0 : 20170503 : DLM : Tried to put it back in but get IDL An in-use...bla error on load program 552,00260318um
14 : 0 : 1 : 0 : 20150521 : GB : In no_pos list in old flat (20150513 flat). However, was able to add the other 4 in the cross back in
#
# Actuators not used when Influence functions were measured (from m2c.fits)
#
2 : 0 : 1 : 0 : 20170509 : DLM : Actuators not in Influence Functions
32 : 0 : 1 : 0 : 20170509 : DLM : Actuators not in Influence Functions
165 : 0 : 1 : 0 : 20170509 : DLM : Actuators not in Influence Functions
373 : 0 : 1 : 0 : 20170509 : DLM : Actuators not in Influence Functions
451 : 0 : 1 : 0 : 20170509 : DLM : Actuators not in Influence Functions
511 : 0 : 1 : 0 : 20170509 : DLM : Actuators not in Influence Functions
578 : 0 : 1 : 0 : 20170509 : DLM : Actuators not in Influence Functions

# No ICC
#
149 : 0 : 0 : 1 : 20170504 : DLM : High forces in flat 0.2N and in CL 0.27N
332 : 0 : 0 : 1 : 20170504 : DLM : Jump in CL to high forces of -0.29N

18:32
  • Hexapod: -0.5075 0.466 5.364 112.524 -47.9636
  • Cube Rotator: 179.460
  • Cube Stage -0.2 (dust mote at -0.1)
  • Bayside stages -73.0 -51.0 35.0
  • Camera Lens Y: -20.84, X: 34.56
  • Saving Board Setup: RetroRef0517

18:39
  • Using old supervisor and P_beta/Clear, as we don't get enough light through the cube for FeII
  • Using Disturb: /local/aomeas/adsec_calib/M2C/KL_v20/disturb/CmdDisturb_20170509_215049.fits
    • Generated by sinus_generate with 30nm Z5 and 0.8" seeing disturbance file
  • Dataset: 192226
  • Dataset with 20 LUCI frames: 192521,193029,193029
  • Unbelievable vibrations. The data are rubbish.
  • New LUCI darks.
  • 193631

| Tracknum | 20170510_193631 |
| Closed Loop | Yes |
| Is OK? | No - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error |
| AntiDrift | ON |
| nphotons/sub/fr | 427.526581 |
| Magnitude | 7.862766 |
| # Modes | 400 |
| Modal rec | Rec_20160229_184300.fits |
| Binning | 1 |
| Frequency [Hz] | 989 |
| Modulation | 2.998804 |
| FW1 | Dichroic 600-1000 nm |
| FW2 | FB850-10 |
| Gain minmax | 0.291000 0.652800 |
| Telescope elevation | 323999.990582 |
| Wind speed | 0.000000 |
| lambda [um] | 1.280000 |
| exptime [s] | 0.156725 |
| framerate [Hz] | 6.380603 |
| no. frames | 20 |
| SR SE | 0.129296 |
| LUCI dark | 20170510_193545.fits_cube.fits |

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170510_192226 ??? 7.8 324000 7 NaN -1.00 184300 1 400 990 0.7 0.4 0.3 3 434 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170510_192348 ??? 7.9 324000 4 NaN -1.00 184300 1 400 990 0.7 0.4 0.3 3 432 ON -1.0 ? -1 -1 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170510_192521 ??? 7.8 324000 4 NaN -1.00 184300 1 400 990 0.7 0.4 0.3 3 436 ON 12.3 P_beta clear 157 20 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170510_193029 ??? 7.9 324000 8 NaN -1.00 184300 1 400 990 0.7 0.4 0.3 3 432 ON 12.9 P_beta clear 157 20 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170510_193631 ??? 7.9 324000 7 NaN -1.00 184300 1 400 990 0.7 0.4 0.3 3 428 ON 12.9 P_beta clear 157 20 ON NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error

20:36
  • Trying to find the source of vibrations.
  • Dataset: 203718, 205450,210055,210204

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170510_203617 ??? 7.9 324000 3 NaN 0.34 184300 1 400 990 0.7 0.4 0.3 3 430 ON 12.6 P_beta clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170510_203718 ??? 7.9 324000 4 NaN 0.34 184300 1 400 990 0.7 0.4 0.3 3 430 ON 14.1 P_beta clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170510_205450 ??? 7.9 324000 6 NaN 0.34 184300 1 400 990 0.7 0.4 0.3 3 430 ON 14.3 P_beta clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170510_205829 ??? 7.9 324000 3 NaN 0.34 184300 1 400 990 0.8 0.4 0.2 3 427 ON -1.0 ? -1 -1 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170510_205955 ??? 7.9 324000 3 NaN 0.33 184300 1 400 990 0.8 0.4 0.2 3 431 ON -1.0 ? -1 -1 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170510_210055 ??? 7.8 324000 6 NaN 0.34 184300 1 400 990 0.8 0.4 0.2 3 433 ON 15.3 P_beta clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170510_210204 ??? 7.9 324000 4 NaN 0.34 184300 1 400 990 0.8 0.4 0.2 3 432 ON 15.7 P_beta clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error

21:05
  • Running AutoFocusLuci.py
  • Found best focus 36.825
  • Dataset: 212104
  • Gains for the above 0.74 0.41 0.25
  • Now gains 0.79 0.41 0.25
  • Dataset: 212517
  • Gopt Gain 0.68

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170510_212011 ??? 7.9 324000 6 NaN 0.34 184300 1 400 990 0.7 0.4 0.2 3 432 ON 14.8 P_beta clear 157 100 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170510_212104 ??? 7.8 324000 4 NaN 0.34 184300 1 400 990 0.7 0.4 0.2 3 433 ON 15.0 P_beta clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170510_212500 ??? 7.8 324000 4 NaN 0.34 184300 1 400 990 0.7 0.4 0.2 3 434 ON 15.8 P_beta clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error

21:51
  • Starting a reconstructor measurement with new actuator map, as defined at the beginning of the day.
  • Disturb: 220910.fits
  • 4 iteration intmat: 222958, 224949, 225806, 232027
  • Rec 223616, 224210, 232203

23:25
  • Starting 48 iterations
  • gain 0.3
  • reconstructor 232203

-- %USERSIG{GregoryTaylor - 2017-05-10}%
Topic revision: r4 - 11 May 2017, DougMiller