SX Actuator tests

17:13 Closed loop.
  • A lot of tip/tilt
  • looks like camera running at 990 and TT mirror at 300
  • Set loop params to 1, 990, 6.0
  • Get error below
  • Stop/Start CCD39 process
    • Same error
  • Stop/Start Slope Computer
    • Set bin to 2
    • Apply loop params
    • OK
WfsArbitrator_58431|DEB|       176|2017-05-09 17:13:55.929741|             MAIN > arbFunc modifyAOInternal (, 'FLAOWFS', '', 990, 1, 3, -1, -1, 1, 'False')
WfsArbitrator_58431|DEB|       177|2017-05-09 17:13:55.995305|             MAIN > ('selected program 1x1, 2500 kpix/sec',)
WfsArbitrator_58431|DEB|       178|2017-05-09 17:13:55.995334|             MAIN > ('Delay base 949, delay inc 1, repetitions 61',)
WfsArbitrator_58431|DEB|       179|2017-05-09 17:13:55.995354|             MAIN > ('Real framerate 989.609104 Hz',)
WfsArbitrator_58431|INF|       180|2017-05-09 17:13:56.093619|             MAIN > Setting tiptilt to amp= 2.00, freq= 0.00, offx= 0.00, offy= 0.00
WfsArbitrator_58431|INF|       181|2017-05-09 17:13:56.094039|             MAIN > calibHODarkInternal(): starting measure, 100 frames
WfsArbitrator_58431|INF|       182|2017-05-09 17:13:56.595921|             MAIN > ccd.equalize_quadrants(): Current settings: bin 1, readout speed 2500 kpix/sec
WfsArbitrator_58431|INF|       183|2017-05-09 17:13:56.596192|             MAIN > ccd.equalize_quadrants(): Starting values: (672, 709, 690, 695)
WfsArbitrator_58431|ERR|       184|2017-05-09 17:13:58.701314|             MAIN > Reading shared buffer masterdiagnostic.L:OPTLOOPBUF (-5001) TIMEOUT_ERROR
Article text.

17:23 Closed loop.
  • Optimize Gain
WfsArbitrator_58431|ERR|       260|2017-05-09 17:23:42.794176|             MAIN > IDL variable undefined 'gainv'

17:30 Close Loop
  • Optimize Gain
  • Failed with same error

17:30 Stop/Start WFSARB
  • Closed Loop
  • Optimize Gain: Success
  • Opt Gain 1.23, 0.55, 0.35

18:00 Opt Loop Data
  • 180003

18:40 act_add account
  • Closed Loop
  • Opt Gain 0.93, 0.28, 0.30
  • 184111
    • Incorrect determination of OL disturbance in model plot

19:00 Stop/Start wfs processes
  • Troubles getting CCD47 to start
  • Power off CCD47 Little Joe. No help

19:15 Stop/Start wfs processes
  • OK, all works now
  • disturbance 0.8"
  • Opt Gain: Problem with HO2: can only put 0.10 before stripping and skip frame
  • Will change actuators

19:48 Change actuators not in Influence Functions from no_curr to no_pos
  • 2 14 32 165 373 451 511 539 578
  • 195748
  • if_act_195748
  • load flat, 380 modes

20:09 Change actuators not in Reconstructor Matrix
  • 1 2 6 14 32 37 165 216 234 262 297 340 373
  • 385 393 409 451 476 483 484 501 511 530 539 541 546
  • 578 654
  • Closed Loop
  • Opt Gain: a lot of stripping and skip frames
  • Open Loop
  • Load old_flat_192925_400.sav
    • 642 modes
  • Close Loop
  • Opt Gain 0.96, 0.2, 0.3
  • 203746
  • rec_act_203746_400

20:40 Closed Loop with 0.8"/2 seeing
  • Opt Gain 1.07, 0.58, 0.31
  • 204210

20:50 Closed Loop with 1.5"/2 seeing
  • Opt Gain 1.7, 0.6, 0.49
  • 205251

21:13 Create Opt Gain file with 30 nm signal
  • 20170509_211335
  • Close Loop, Opt Gain (0.5) and NCPA ON

21:22 Start LUCI1
  • Center

21:51 Generate Disturbance file with Gopt signal
  • 30nm + 0.8"/2 = 20170509_215049
  • 30nm + 1.5"/2 = 20170509_215326

22:00 Gopt On, no disturbance
  • 220016

22:05 Gopt on + 0.8"/2 seeing
  • Opt Gain 1.12, 0.5, 0.31
  • focus 55.3
  • 221137
  • 222942 with LUCI1 47.2%
  • 223027 with LUCI1 48.5%
  • 223512 with LUCI1 50.o%
  • 223859 with LUCI1 49.3%
  • focus 55.1
  • 224058 with LUCI1 49.8%
  • 224115
  • focus 54.8
  • 224250
  • 224412

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
Focus = 55.3
20170509_222942 ??? 9.7 324000 1 NaN 0.38 184300 1 400 990 0.3 0.2 0.1 3 79 ON 48.8 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170509_223027 ??? 9.7 324000 6 NaN 0.38 184300 1 400 990 0.3 0.2 0.1 3 80 ON 47.6 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170509_223158 ??? 9.7 324000 2 NaN 0.38 184300 1 400 990 0.3 0.2 0.1 3 78 ON 51.2 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170509_223512 ??? 9.7 324000 2 NaN 0.39 184300 1 400 990 0.3 0.2 0.1 3 76 ON 51.1 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170509_223859 ??? 9.7 324000 8 NaN 0.38 184300 1 400 990 0.3 0.2 0.1 3 79 ON 49.5 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
Focus = 55.1
20170509_224058 ??? 9.7 324000 8 NaN 0.39 184300 1 400 990 0.3 0.2 0.1 3 77 ON 50.1 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170509_224115 ??? 9.7 324000 5 NaN 0.38 184300 1 400 990 0.3 0.2 0.1 3 79 ON 30.2 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
Focus = 54.8
20170509_224250 ??? 9.7 324000 7 NaN 0.38 184300 1 400 990 0.3 0.2 0.1 3 78 ON 53.9 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170509_224412 ??? 9.7 324000 3 NaN 0.38 184300 1 400 990 0.3 0.2 0.1 3 76 ON 51.2 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error

22:45 LUCI1 dark 224512

22:45 CCD39 dark 224541

22:48 300 mode, gopt, 0.8"/2
  • 1.06, 0.41, 0.38
  • 224944
  • 225425 no NCPA 52%
  • 225726 NCPA on 57%
  • 225900

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170509_225425 ??? 9.7 324000 5 NaN 0.38 062006 1 300 990 0.5 0.2 0.2 3 77 ON 52.3 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170509_225726 ??? 9.8 324000 5 NaN 0.38 062006 1 300 990 0.4 0.2 0.2 3 74 ON 57.0 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170509_225754 ??? 9.8 324000 7 NaN 0.40 062006 1 300 990 0.4 0.2 0.2 3 75 ON 55.6 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170509_225900 ??? 9.8 324000 4 NaN 0.38 062006 1 300 990 0.4 0.2 0.2 3 73 ON 56.3 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error

23:03 400 mode, gopt, 1.5"/2
  • opt gain 1.3, 0.6, 0.41
  • 231327
  • 232328
  • 232350

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170509_232328 ??? 9.7 324000 2 NaN 0.74 184300 1 400 990 0.4 0.2 0.1 3 76 ON 50.7 FeII clear 157 20 ONSKY NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170509_232350 ??? 9.8 324000 2 NaN 0.76 184300 1 400 990 0.4 0.2 0.1 3 73 ON 60.4 FeII clear 157 20 ONSKY NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error

23:34 400 mode, gopt, 0.8"/2
  • opt Gain 1.13, 0.49, 0.38
  • 233815 No LUCI1
  • 234139
  • 234154 52%
  • 234219 54%
  • 234306 Lower gains 52%
  • 244331 Lower gains 53%

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170509_234129 ??? 9.8 324000 1 NaN 0.41 184300 1 400 990 0.4 0.2 0.1 3 75 ON 53.8 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170509_234154 ??? 9.7 324000 1 NaN 0.41 184300 1 400 990 0.4 0.2 0.1 3 76 ON 52.5 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170509_234219 ??? 9.7 324000 2 NaN 0.40 184300 1 400 990 0.4 0.2 0.1 3 76 ON 55.4 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170509_234306 ??? 9.8 324000 0 NaN 0.42 184300 1 400 990 0.4 0.1 0.1 3 72 ON 52.1 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170509_234331 ??? 9.7 324000 1 NaN 0.42 184300 1 400 990 0.4 0.1 0.1 3 76 ON 53.3 FeII clear 157 20 ONSKY NO - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error

25:34
  • 254504
  • 234539

-- %USERSIG{DougMiller - 2017-05-09}%
Topic revision: r5 - 11 May 2017, DougMiller
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.