DX Closed Dome Performance

ARGOS CalUnit (20170509)

The performance results below are from measurement taken with the ARGOS CalUnit.

We collected AO Telemetry data and LUCI images for bin 1, 300 mode and 400 mode reconstructors.

The loop parameters were similar in both cases, with the loop gains determined via the Optimize Gain routine.

A 1.6" seeing disturbance was applied to the AdSec. Note, this 1.6" seeing disturbance file was calculated for the RetroReflector so with the single pass ARGOS CalUnit we are actually applying only half of the disturbance to the wavefront. This can be seen in the tables below where the Open Loop Seeing (OL) is reported to be slightly around 0.8".

300 Mode Closed Loop
  • Gains 1.16 0.60 0.69
  • 0.8" Seeing
  • Gopt On
  • NCPA Applied

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170509_231308 ??? 9.4 324000 4 NaN 0.80 012542 1 300 990 0.9 0.6 0.4 0 105 ON 44.2 FeII clear 157 50 ONSKY NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Pyramid modulation mismatch - SR may be in error
20170509_231523 ??? 9.4 324000 2 NaN 0.87 012542 1 300 990 0.4 0.3 0.2 0 106 ON 41.0 FeII clear 157 50 ONSKY NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error - Pyramid modulation mismatch - SR may be in error

  • 300 Mode Recon:
    20170510_231308_modal.jpg

  • 300 Mode Recon:
    20170510_231308_jitter.jpg

  • 300 Mode Recon:
    20170510_231308_psf.jpg

400 Mode Closed Loop
  • Gains 0.91 0.60 0.44
  • 0.8" Seeing
  • Gopt On
  • NCPA Applied

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20170509_225154 ??? 9.4 324000 3 NaN 0.87 014135 1 400 990 0.4 0.2 0.2 3 108 ON 61.4 FeII clear 157 50 ONSKY NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error
20170509_225246 ??? 9.4 324000 3 NaN 0.86 014135 1 400 990 0.4 0.2 0.2 3 107 ON 61.9 FeII clear 157 50 ONSKY NO - CRC error - FLTimeout error - PendingCounter error - SkipCounter error - TimeStamp error - WFSGlobalTimeout error

  • 400 Mode Recon:
    20170510_225154_modal.jpg

  • 400 Mode Recon:
    20170510_225154_jitter.jpg

  • 400 Mode Recon:
    20170510_225154_psf.jpg

-- %USERSIG{DougMiller - 2017-05-11}%

I Attachment Action Size Date Who Comment
20170510_225154_jitter.jpgjpg 20170510_225154_jitter.jpg manage 127 K 11 May 2017 - 11:44 DougMiller 400 Mode Recon
20170510_225154_modal.jpgjpg 20170510_225154_modal.jpg manage 76 K 11 May 2017 - 11:43 DougMiller 400 Mode Recon
20170510_225154_psf.jpgjpg 20170510_225154_psf.jpg manage 125 K 11 May 2017 - 11:44 DougMiller 400 Mode Recon
20170510_231308_jitter.jpgjpg 20170510_231308_jitter.jpg manage 123 K 11 May 2017 - 11:49 DougMiller 300 Mode Recon
20170510_231308_modal.jpgjpg 20170510_231308_modal.jpg manage 80 K 11 May 2017 - 11:49 DougMiller 300 Mode Recon
20170510_231308_psf.jpgjpg 20170510_231308_psf.jpg manage 119 K 11 May 2017 - 11:50 DougMiller 300 Mode Recon
Topic revision: r1 - 11 May 2017, DougMiller