SX Check of old actuator lists

Reconstructors

"Recon List" Actuator list when current reconstructors were measured

Bin 1
  • /local/aomeas/adsec_calib/M2C/KL_v20/RECs/Rec_20160229_184300.fits
    • IM_ACQ_D= 'M2C/KL_v20/intmatAcq/20160229_182544/'
    • IM_MODES= '400.000 '

Flat applied
  • /local/aomeas/adsec_calib/CMD/shape/20160229_172130_stability_default.sav
IDL> restore, '20160229_172130_stability_default.sav', /V  
IDL> print, where(flattened_status.closed_loop EQ 0.0)
           1           2           6          14          32          37         165         216         234         262         297         340         373
         385         393         409         451         476         483         484         501         511         530         539         541         546
         578         654
IDL> print, n_elements(where(flattened_status.closed_loop EQ 0.0))
          28

20170508_SX_Recon_List bad_actuator.list used when the Reconstructor was measured

"Big List" the current actuator list used in the production AO Supervisor

Flat applied
  • /local/aomeas/adsec_calib/CMD/shape/20170508_124535_stability_LUCIFER.sav
IDL> restore, '20170508_124535_stability_LUCIFER.sav', /v
IDL> print, where(flattened_status.closed_loop EQ 0.0)            
           1           2           3           6          14          24          32          37          80         148         149         151
         165         175         216         228         234         253         259         261         262         278         297         332
         340         367         370         373         385         393         394         409         428         431         451         476
         483         484         491         501         510         511         527         530         539         541         546         552
         578         652         654
IDL> print, n_elements(where(flattened_status.closed_loop EQ 0.0))                      
          51

20170508_SX_Big_List bad_actuator.list with the current actuator list used in the production AO Supervisor

Old flat used to add actuator back into use

Flat /local/aomeas/adsec_calib/flat/Applicable/20150513_181300.sav

IDL> restore, '20150513_181300.sav', /v IDL> print, where(flattened_status.closed_loop EQ 0.0) 14 32 373 511

"IF List" Influence Functions

IDL> im = readfits('/local/aomeas/adsec_calib/M2C/KL_v20/m2c.fits')
IDL> print, where(total(abs(im),1) EQ 0.0)   
           2          14          32         165         373         451         511         539         578
IDL> print, n_elements(where(total(abs(im),1) EQ 0.0))
           9

SIMPLE  =                    T / Written by IDL:  Fri Feb  5 19:29:14 2016      

20170508_SX_IF_List bad_actuator.list used when the Influence Functions were measured