SX Actuator testing and Flats

15:15 ARGOS CalUnits deployed

15:30 copied aoroot to act_add and restarted AdSec

15:40 Stopped ARGOS WFS process and started FLAO processes

16:36 Closed Loop
  • had troubles with pupil check routine. Had to switch to bin 2 then back to bin 1
  • Optimize Gain 1.0, 0.3, 0.3

16:47 Opt Loop Data
  • disturbance dist_flao2_KL_v18_ atm_s0.8_l040.0_15.0_ovfreq_1000.00_sd1983.fits
  • Optimize gain 1.0, 0.6, 0.4
  • 164913

18:30 Get bad_actuator.list and IDL routines installed
  • List is the same
  • Flat has 620 modes

18:40 There is a bump that does not change at 11:30 in Closed Loop
  • add act 149 and 151 back from pos list

18:50 restart and set
  • 149 now has high force
  • only 239 modes applied
  • Add 149 to no_icc list

19:03 restart and set
  • 239 modes in flat
  • still high current at 149
  • add 149 to no_pos list

19:15 restart and set
  • 252 modes
  • 151 high currents
  • add 151 to no_pos list
  • remove 148 from no_pos list

19:25 restart and set
  • 205 modes
  • add 148 to no_icc list

19:35 restart and set
  • 235 modes
  • add 148 to no_pos

19:45 restart and set
  • back to original lists
  • 620 modes

19:50 work on cross at 2:00
  • put back in pos list 1,2,3,6,14

19:59 Get cross with high (-0.38+) currents for 1,2,3,6,14
  • 625 modes applied
  • put 1,2,3,6,14 in no_icc list

20:07 restart and set
  • When Set get "An in-use actuator used in not working anymore"
  • Power cycle and set.
    • goes this time
    • same high current cross
  • put 2 in no_curr list

20:18 restart and set
  • 624 modes
  • still get cross of high currents, but less current on 1 and 6
  • add 14 to no_curr

20:25 restart and set
  • 260 modes
  • high current at 1 and 7 (0.15, not too bad)

20:29 Leaving list as is

-- %USERSIG{DougMiller - 2017-05-02}%