DX TT Offet LUT, Flat and Actuators

TT Offset LUT

15:00 Closed loop
  • board setup ARGOS123
  • Hex -3.44, -1.30, 0.97, -260, -322
  • Instrument Rotator Off
  • Bayside stage Off
  • No pattern noise on CCD39
  • opt gain 1.06, 0.14, 0.21
  • The HO1 gain seems low
  • Opt Loop Data 150355

16:33 Darks
  • 91 2.5X1
  • 92 2.5X10
  • 93 20x1

19:02 Will look at data tonight and maybe remeasure tomorrow

20:59
  • Gains: 1.43 0.20 0.28
  • Opt Loop Data 210006
  • Flat Saved: test_210006_300.txt

Flat and Actuators

19:03 Switch to other AO Supervisor

19:12:30 Flat Set * 192 modes

19:39 Actuators with high current
  • 460: -0.338
  • 366: -0.298
  • 342: -0.297
  • 475: -0.237
  • 371: -0.218

19:45
  • add 460 to ICC list
  • cycle power

19:56:31 Flat Set
  • 198 modes
  • 450: -0.34
  • 475: -0.298
  • 342: -0.264

20:00 Add 450 to No ICC list

20:17 Closed Loop
  • 300 modes
  • Opt Loop Data 201807
  • Flat test_201807
  • Apply flat: 175 modes, 207, 175

20:28:17 Restart and Set
  • 188 modes
  • 342: -0.28
  • 475: -0.27
  • 450: -0.257 (no icc but high current)

20:35 Add 342 and 475 to No ICC list

20:39:51 Restart and Set
  • 185 modes, 192
  • flat test_201807 208 modes, 207

21:25 Put a bunch of actuators back in use
  • 367, 91, 72, 87, 115, 145, 340, 451, 557, 559, 218, 232

21:35 Put 340 in No ICC list because of a bump at 6:30

21:43 Restart and Set
  • 454: -0.30
  • 474: -0.30
  • 451: 0.32
  • 229: -0.29
  • 342: -0.28
  • 117: -0.28

22:08 Put 115 in No ICC list
  • bump at 10:00

22:22 Put 115 in No Curr list
  • bump gone
  • Opt Loop Data 222636
  • bump at 87. Was in No Curr list. will put in No ICC list tomorrow
  • flat test_222636_300
  • load flat: 230 modes

TT Offset LUT

Gains: 0.85 0.20 0.20

Angle Off On Z Comment
-90 0001 0002 0003  
-45 0005 0006 0004  
0 0007 0008 0009  
45 0011 0012 0010  
90 0013 0014 0015  
135 0017 0018 0016  
180 0019 0020 0021  
225 0023 0024 0022  
270 0025 0026 0027  
315 0029 0030 0028  
360 0031 0032 0034  
405 0036 0037 0035  
450 0038 0039 0040  

Angle Off On Z Comment
450 0042 0043 0041  
405 0044 0045 0046  
360 0050 0051 0047  
315 0052 0053 0055  
270 0057 0058 0056  
225 0058 0059 0060  
180 0063 0064 0062  
135  
90  
45  
0  
-45  
-90  