SX TT LUT

Hexapod:
  • 4.5 3.1 -0.23 -89.8 15.1 0

16:11 About setup with closed loop and LUCI1

16:14 x
  • LUCI position 253, 1164
  • Stages -70., -50., 54.6
  • 75% of opt gain 0.8, 0.35, 0.2
  • Rotate to 360
    • 269, 1149
    • From 20170417 333.750,1533.283 360.00

16:36 Move to 20170417 position
  • bayside x delta -0.5 = 62 pixels to the right (315, 1148)
  • bayside y delta +0.5 = 65 pixels up (315, 1213)
  • -70.64, -46.66
  • 330, 1530

16:54 Turn off bayside stages
  • 331, 1530

16:56
  • TT 0,0
    • 331, 1530
  • TT -3.0 0
    • 371, 1513
  • TT 0, 0
    • 331, 1530
  • TT 3.0, 0
    • 291, 1549

17:52
  • TT 0,0
    • 333, 1531
  • TT 0, -3
    • 314, 1494
  • TT 0,0
    • 333, 1530

18:00 Rotate to 450

18:02

450 20 K 06 Off
450 2.5 OH1060,Z 09 Off
450 2.5 OH1060,Z 10 On
360 2.5 OH1060,Z 11 On
360 2.5 OH1060,Z 12 Off
360 20 K 13 Off
270 20 K 14 Off
270 2.5 OH1060,Z 15 Off
270 2.5 OH1060,Z 16 On
180 2.5 OH1060,Z 18 On
180 2.5 OH1060,Z 17 Off
180 20 K 19 Off
90 20 K 20 Off
90 2.5 OH1060,Z 21 Off
90 2.5 OH1060,Z 22 On
0 2.5 OH1060,Z 23 On
0 2.5 OH1060,Z 24 Off
0 20 K 25 Off
-90 20 K 26 Off
-90 2.5 OH1060,Z 27 Off
-90 2.5 OH1060,Z 28 On
18:52 Darks
  • 29 2.5x1
  • 31-40 2.5x10
  • 41 20x1

19:00 Center of rotation on LUCI1
  • 02 40x1
  • center at 995, 1111.5
  • Move Hexapod in zero coma mode by Tip=-8.9, Tilt=7.2
  • Move bayside stages to -76.8, -51.1
  • 996, 1120

19:46 Rotate in closed loop to -90
  • 1073, 1086
  • center at 1035, 1103 *1037, 1102
  • bayside -76.56, -50.7

-90 20 K 14 Off
-90 2.5 OH1060,Z 15 Off
-90 2.5 OH1060,Z 16 On
-45 2.5 OH1060,Z 17 On
-45 2.5 OH1060,Z 18 Off
-45 20 K 19 Off
0 20 K 20 Off
0 2.5 OH1060,Z 22 Off
0 2.5 OH1060,Z 23 On
45 2.5 OH1060,Z 24 On
45 2.5 OH1060,Z 25 Off
45 20 K 26 Off
90 20 K 27 Off
90 2.5 OH1060,Z 28 Off
90 2.5 OH1060,Z 29 On
135 2.5 OH1060,Z 30 On
135 2.5 OH1060,Z 31 Off
135 20 K 32 Off
180 20 K 33 Off
180 2.5 OH1060,Z 34 Off
180 2.5 OH1060,Z 35 On
225 2.5 OH1060,Z 36 On
225 2.5 OH1060,Z 37 Off
225 20 K 38 Off
270 20 K 39 Off
270 2.5 OH1060,Z 40 Off
270 2.5 OH1060,Z 41 On
315 2.5 OH1060,Z 42 On
315 2.5 OH1060,Z 43 Off
315 20 K 44 Off
360 20 K 45 Off
360 2.5 OH1060,Z 46 Off
360 2.5 OH1060,Z 47 On
405 2.5 OH1060,Z 48 On
405 2.5 OH1060,Z 49 Off
405 20 K 50 Off
450 20 K 51 Off
450 2.5 OH1060,Z 52 Off
450 2.5 OH1060,Z 53 On

  2.5 OH1060,Z   On
  2.5 OH1060,Z   Off
  20 K   Off
  20 K   Off
  2.5 OH1060,Z   Off
  2.5 OH1060,Z   On
  2.5 OH1060,Z   On
  2.5 OH1060,Z   Off
  20 K   Off
  20 K   Off
  2.5 OH1060,Z   Off
  2.5 OH1060,Z   On
  2.5 OH1060,Z   On
  2.5 OH1060,Z   Off
  20 K   Off
  20 K   Off
  2.5 OH1060,Z   Off
  2.5 OH1060,Z   On
  2.5 OH1060,Z   On
  2.5 OH1060,Z   Off
  20 K   Off
  20 K   Off
  2.5 OH1060,Z   Off
  2.5 OH1060,Z   On
  2.5 OH1060,Z   On
  2.5 OH1060,Z   Off
  20 K   Off
  20 K   Off
  2.5 OH1060,Z   Off
  2.5 OH1060,Z   On
  2.5 OH1060,Z   On
  2.5 OH1060,Z   Off
  20 K   Off
20:58
  • optimize gain
  • 1.23, 0.35, 0.30

21:00
  • HO dark 20170421_205951
  • stop start WFSARB
  • opt gain: 0.94, 0.35, 0.3

21:06 Opt Loop Data
  • 300 mode
  • 990 Hz
  • 9.5 mag
  • 210738

22:51 Test LUT Gains 1.23 0.50 0.30
  • Changed TT gain to 0.93
Angle OH1060+z K Comments
0 0057 0056  
90 0058 0059  
180 0061 0060  
270 0062 0063  
315 0065 0064  
225 0066 0067  
135 0069 0068  
45 0070 0071  

Hexapod Pos 4.134 3.555 -0.2333 -172.241 36.756 -- %USERSIG{GregoryTaylor - 2017-04-21}%