SX Daytime test of communication problems to Switch BCU

15:28 Startup system and check for error
  • Get timeout errors
  • No CRC errors

[AOeng@flao-sxwfs ChUI]$ ./BCUread 1030 2 DSP

0x00001030:
0x0000A46F 00042095        0.0000000000
0x00000000 00000000        0.0000000000

[AOeng@flao-sxwfs ChUI]$ ./BCUread 1030 2 DSP

0x00001030:
0x0000AD4F 00044367        0.0000000000
0x00000000 00000000        0.0000000000

[AOeng@flao-sxwfs ChUI]$ ./BCUread 1030 2 DSP

0x00001030:
0x0000B41C 00046108        0.0000000000
0x00000000 00000000        0.0000000000

15:52 Leroy and Chris find 4 dB loss in full length of fiber from SX FLAO WUnit to SX Switch BCU
  • This well within acceptable range.
  • No problems with fiber

16:05 SX LBTI Test
  • Having the same timeout problems
  • No CRC Errors
[root@lbti-sxwfs6 ~]# cd /root/aosource/ChUI/
[root@lbti-sxwfs6 ChUI]# ./BCUread 1030 2 DSP

0x00001030:
0x00000000 00000000        0.0000000000
0x00000000 00000000        0.0000000000

[root@lbti-sxwfs6 ChUI]# ./BCUread 1030 2 DSP

0x00001030:
0x00002C63 00011363        0.0000000000
0x00000000 00000000        0.0000000000

[root@lbti-sxwfs6 ChUI]# ./BCUread 1030 2 DSP

0x00001030:
0x000033F2 00013298        0.0000000000
0x00000000 00000000        0.0000000000

-- %USERSIG{DougMiller - 2017-03-18}%
  • Switch BCU Version GUI:
    Switch_BCU_Version.jpg
Topic revision: r2 - 18 Mar 2017, DougMiller
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.